Permit Number: D06-0032
Parcel: 13342001F

Address:
1925 N KOLB RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D06-0032
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/16/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
05/16/2007 WILDAN ZONING REVIEW Passed
05/16/2007 WILLDAN ENGINEERING REVIEW Passed
05/16/2007 WILDAN LANDSCAPE REVIEW Passed
05/30/2007 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approv-Cond DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D06-0032 First Magnus National Office 05/30/07

() Tentative Plat
(X) Development Plan
(X) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: Prior to the issuance of a Certificate of Occupancy by DSD, D06-0032 shall comply with C9-06-24 Alta Vista Communities – Kolb Rd.

NEIGHBORHOOD PLAN: General Plan

GATEWAY : Yes

COMMENTS DUE BY: June 14, 2007

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

Prior to Cert. Of Occupancy, Proposal Shall Comply with Rezoning C9-06-24
(X) See Additional Comments Attached








REVIEWER: msp 791-4505 DATE: May 30, 2007

Department of Urban Planning & Design Comments
D06-0032 – First Magnus National Office
May 30, 2007

Staff offers the following comments:

Urban Planning and Design staff releases this review as a phased conditional approval with a resubmittal required for the next phase showing a development plan that meets C9-06-024, rezoning conditions, and subject to the following condition:

This release prohibits the issuance of a Certificate of Occupancy (C of O). Prior to a C of O issuance a development plan shall be resubmitted and shall require to be in full compliance with rezoning case C9-06-24, or in compliance as determined by the Director of Urban Planning and Design, and the Director of Development Services.
05/30/2007 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond May 30, 2007

To: Craig A. Hunt, P.E.
Engineering and Environmental Consultants, Inc.

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

From: Chandubhai C. Patel, P.E., Civil Eng. Manager
Development Review Division (Wastewater)
Pima County Development Services Department

Subject: First Magnus Office Building
Development Plan – 3rd Submittal
D06-032

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


1.You are proposing, as part of this project, to connect the proposed sewer line into the 8-inch public sewer G-2004-027. However, this public sewer G-2004-027 has not been formally accepted for service by the PCWMD or ADEQ.

We are aware that the construction of the G-2004-027 sewer line was substantially completed in 2005, and that the unauthorized use of this sewer has started since May of 2005. The efforts to formalize the acceptance, without enforcement action, of this sewer line by the PCWMD are underway.

The Developer and the Engineer for the First Magnus Office Building understand and agree that the sewer service to this development will not be available until such time as the public sewer G-2004-027 is accepted by the PCWMD in the Pima county public sewer system and released for service.

2.SUBJECT TO THE ABOVE, the Pima County Department of Environmental Quality and the Wastewater Management Department hereby CONDITIONALLY approve the above referenced submittal of the Development Plan received by us on May 14, 2007.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to

The construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality Department.

Also, air quality activity permits must be secured by the developer or prime contractor from Pima County Department of Environmental Quality before constructing, operating, or engaging in any activity which may cause or contribute to air pollution.


If you have any question regarding the above comments, please do not hesitate to contact me.

Sincerely,




Chandubhai C. Patel, P.E
520-740-6563.


Copy: Project file
05/31/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 31, 2007

Craig Hunt
Engineering and Environmental Consultants, Inc.
4625 East Fort Lowell Road
Tucson, Arizona 85712

Subject: D06-0032 First Mangus National Bank Development Plan

Dear Craig:

The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per on-line comments, please submit the following documents for sign-off.

1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal).
AND
1 Double Matte right-reading Océ or Photo Mylar of the Development Plan.

The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options.

TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html.

PRIOR TO SIGNING THE MYLAR THE CITY OF TUCSON CDRC OFFICE WILL NEED A PERMIT APLICATION NUMBER FOR THE BUILDING DUE TO CONDITIONAL APPROVALS FROM WILDAN, WASTEWATER, AND DUPD PLACING HOLDS ON THE CERTIFICATE OF OCCUPANCY.

Should you have any questions, please call me at 791-5608 extension 1179.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 321-0333