Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D06-0029
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/12/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/26/2007 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approved | July 25, 2007 TO: Elizabeth Ohep-Franco Tait & Associates, Inc. THRU: Patricia Gehlen, CDRC Manager City of Tucson, Development Services Department FROM: Tom Porter, Sr. CEA Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: Fry’s Fueling Station #119 Development Plan – 4th Submittal D06-0029 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan as submitted. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me. Sincerely, Tom Porter Telephone: (520) 740-6579 Copy: Project File |
| 07/30/2007 | JASON GREEN | ENGINEERING | REVIEW | Approved | DATE: July 30, 2007 SUBJECT: Fry's Fuel Facility Development Plan submittal- 4th Engineering Review TO: Patricia Gehlen, CDRC Manager LOCATION: 904 W Irvington Road, T14S R13E Section 35 Ward 1 REVIEWERS: Jason Green, CFM ACTIVITY: D06-0029 SUMMARY: Engineering Division of Development Services Department has received the revised proposed development plan, landscape plan, Drainage Report (O'Neill Engineering, Inv., 06JUL07 to be included with the 14DEC06 report) and geotechnical addendum #1. Engineering Division has reviewed the submitted development plan and recommends approval of the development plan at this time. GRADING PLAN: 1) DS Sec.11-01.2.1: The grading permit application (T06BU01651) required for this project, prior to building plan approval, will be reviewed and approved separately. 2) Please ensure the grading plan is consistent with the development plan and drainage report. Grading standards may be accessed at: http://www.ci.tucson.az.us/dsd/DevStandsTOC.pdf 3) Arizona Pollutant Discharge Elimination System (AZPDES) requirements are applicable to this project. Stormwater Pollution Prevention Plans (SWPPP) and text addressing stormwater controls for all areas affected by construction activities related to this development have been submitted with the grading plan submittal and will be reviewed for AZDES requirements. For further information, visit www.adeq.state.az.us/environ/water/permits/stormwater.html. If you have any questions call me at (520) 837-4929. Jason Green, CFM Senior Engineer Associate Engineering Division Development Services |
| 07/30/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approved | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES July 30, 2007 Elizabeth Ohep Tait & Associates, Inc. 2266 South Dobson Road, Suite 208 Mesa, Arizona 85202 Subject: D06-0029Development Plan Dear Elizabeth: The above referenced development plan has been APPROVED by the Community Design Review Committee. Please submit the following documents for sign-off. 1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). AND 1 Double Matte right-reading Océ or Photo Mylar of the Development Plan. The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: (480) 775-5139 |