Permit Number: D06-0021
Parcel: 141185330

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D06-0021
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/18/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/19/2006 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: D06-0021
Southwest Uplink Facility
Development Plan Resubmittal

TRANSMITTAL DATE: September 19, 2006

DUE DATE: October 16, 2006

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Please add to note 10 on sheet 1 of 1 the reference LUC "Sec. 2.8.3" for Major Streets and Routes Overlay Zone.
DS 2-05.2.2.B.10

2. On sheet DP-2 please add zoning designation I-1 for property on north side of Old Vail Road and I-2 for the property south of the Union Pacific Railroad.
DS 2-05.2.4.B

3. Please add to the back-up spur the radii. Per DS 3-05.2.2.D the back-up spur will have a radii of three (3) feet.
DS 3-05.2.2.D

4. Please clarify if note provided for sidewalk width is for sidewalks located on site or for sidewalks within the right-of-way. Minimum width of new sidewalks in Old Vail Road is six (6) feet, on-site four (4) feet.
DS 2-08.5.1.A & MS&R Plan

5. Detectable warnings (truncated domes) are required for access aisles of handicapped motor vehicle parking spaces. The truncated domes shall be installed twenty-four (24) inches minimum in the direction of travel and extend the full width of the curb ramp or flush surface. The domes shall be located so the edge nearest the curb line is six (6) inches to eight (8) inches from the curb line. Please verify that this is provided in the handicapped parking detail
ANSI 406.12, ANSI 705

6. The parking canopy shown on DP-4 must meet required setback of one (1) foot from the edge of the twenty-four (24) foot PAAL. This setback is measured from the closest part of the structure to the PAAL (overhang). A detail should be provided of the carport structure to ensure that structural post does not interfere with the ability of passengers to enter or exit a vehicle. This detail is to be approved by Traffic Engineering. If canopy post do obstruct a vehicle the parking space abutting the vertical barrier must be increased to ten (10) feet in width to accommodate passengers.
DS 3-05.2.2.B.2 & DS 3-05.2.1.B.3

7. All revision made to the development plan must also be made to the landscape, irrigation, NPPO and grading plans.

If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550 ext. 1197.

KAA S:\zoning review\karol\planning\cdrc\developmentplan\D06-0021dp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, additional requested documents.
09/25/2006 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
09/26/2006 JOE LINVILLE LANDSCAPE REVIEW Denied 1) A native plant preservation plan per DS 2-15 will be required if protected plants exist in the area planned for development.

2) Provide 50% vegetative coverage of the street landscape border per LUC 3.7.2.4. Plants used for screening are not calculated as part of the coverage requirement. DS 2-06.3.7
Provide calculations per DS 2-07.2.2.A2.
3) The future right-of-way shown on the landscape plan for Old Vail Road exceeds the current MS&R Plan designation and does not match the development plan. Revise as necessary. DS 2-07.2.0, LUC 3.7.2.4.A.1

4) The landscape plan legend refers to the demolition plan sheet C-1. Sheet C-1 was not received.

5) Obtain approval from the City Engineer for any right-of-way excavation or construction.

6) The native plant preservation submittal is incomplete. Provide the following:

A native plant inventory is required per DS 2-15.3.1.A.1-3, including a list of all protected plants.The list shall include the identification number, genus and species, and size.

An aerial photograph, taken within a maximum of three (3) years of submittal, at a minimum scale of 1” = 60’ showing the site’s boundaries, the locations of all Protected Native Plants within those boundaries, and the plants’ identification numbers keyed to the inventory list.

The Native Plant Viability and Transplantability Status shall be determined for each native plant. Provide the required assessment per DS 2-15.3.2.A

Correct the salvage and mitigation summary and the plan notes for accuracy where necessary. The summary and salvage note for blue palo verde is incorrect. Check others.


7) Revise the landscape plans if/where necessary to coordinate with the native plant preservation proposal. The plan is to include mitigation for native species and is required to provide a key to the symbols for preserved plants, transplants and mitigation plantings.

RESUBMITTAL OF ALL PLANS IS REQUIRED.
10/02/2006 PAUL MACHADO ENGINEERING REVIEW Approved
10/13/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

October 13, 2006

Carlos Madero
Lawson & Associates
7939 Norfolk Avenue, Suite 200
Bethesda, MD 20814

Subject: D06-0021 Southwest Uplink Facility Development Plan

Dear Carlos:

Your submittal of September 18, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Development Plan (Landscape, Zoning, DSD)

3 Copies Revised Landscape Plans (Zoning, Landscape, DSD)

2 Copies Revised NPPO Plans (Landscape, DSD)



Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: (301) 654-1601
10/13/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approved October 13, 2006
TO: Carlos Madero
Lawson & Associates

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: R S Engineering (Contract Reviewer)
Chandubhai Patel, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Southwest Uplink Facility
Development Plan – 3rd Submittal
D06-0021


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The comments of the letter of August 21, 2006 have been satisfied: therefore this project is hereby approved as submitted.

Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative plat.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval to Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality active permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating, or engaging in an activity which may cause or contribute to air pollution.



If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Chandubhai Patel, P.E.
Telephone: (520) 740-6563

Copy: RSE Job # 0432.80