Permit Number: D06-0018
Parcel: 13013083B

Address:
3872 E 34TH ST

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D06-0018
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/16/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
06/21/2006 JIM EGAN COT NON-DSD FIRE Approv-Cond Fire Department requires 20' wide unobstructed access. Hinged post indicated on detail for gate must be removable.
06/22/2006 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Shrubs in areas of required landscaping other than for opaque screening will be a minimum one (1) gallon container size, with twenty (20) percent of the required number to be five (5) gallon container size or larger. Revise the plan.

2) Dimension the length and width of landscape borders on the landscape plan per DS 2-07.2.2.A.2.f.

3) Revise the plant symbols for groundcover plantings to reflect the ultimate size of the plants. DS 2-07.2.2.A.1.c

3) Cissus trifoliata is a vine that will not provide the form or extent of groundcover shown on the landscape plan. Revise as necessary.

4) Revise the plant coverage calcs calculations on the landscape plan. Trees are not included in the groundcover calculations, only shrubs, accent plants, and groundcover plants. Correct the percentage.

RESUBMITTAL OF ALL PLANS IS REQUIRED
06/23/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approved June 22, 2006

TO: Joe Locke
Landlocked Properties

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Roofsavers Yard
Development Plan – 2nd Submittal
D06-0018


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


This project is hereby approved as submitted.


If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
06/26/2006 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends approval of the proposed development plan.
06/28/2006 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: David Rivera
Principal Planner

PROJECT:
D06-018
Roofsavers Yard
3872 E. 34th Street
Development Plan

TRANSMITTAL: June 28, 2006
DUE DATE: July 17, 2006

1. Place the development plan number (D06-018) on each sheet of the development plan, including sheet A1.1.

2. Add a Floor Area Ratio (FAR) to the development plan. The FAR calculation should state the proposed as weel as the maximum allowed FAR. LUC 3.2.11



3. All lettering and dimensions must be a minimum of equivalent of twelve (0.12") point in size. Revise all text on sheet A 1.1 that does not meet this minimum standard along with the numbers in the scale on the development plan sheet. DS 2-05.2.1.C





4. This plan does not meet the criteria for pedestrian circulation. Refer to DS 2-08 for pedestrian circulation requirements. An accessible pedestrian sidewalk must connect the building to adjacent rights-of-way. Revise to show pedestrian connections correctly. Dimension width of pedestrian sidewalks clearly and accurately on the drawing. A minimum 5-foot pedestrian refuge area is required between any building and PAAL.
DS 2-08
DS 3-05

5. All dimensions must be correct and to scale on the plan. Revise the loading zone, parking spaces, handicap parking space, sight visibility triangles, PAAL widths, right-of-way and curb dimensions, entrance drive widths, setback dimensions, easement widths, building dimensions and all other features on the plan to be drawn correctly and to scale. Dimension the width of the entrance drive along the west side of the property. from The dimensions on the parking detail on sheet A1.1 and the dimensions called out on the development plan drawing must be consistent. Dimension PAAL widths. Indicate any one-way/do not enter signage. Revise concrete wheelstops to be dimensioned at 2-1/2 feet from the front of parking spaces. Refer to LUC 3.3.7.2 for motor vehicle and PAAL dimensions required. Provide the angle for the handicap parking space. The handicap parking shown in the detail is at 90 degrees which is not the same as the angled h/c parking shown on the drawing. Revise to provide a h/c parking detail and show truncated domes where required. The dimensions of the trash enclosure detail do not match the d.p. drawing. Revise all dimensions to be accurate. DS 2-05.2.1.B
DS 3-05.2.3.C.2
ANS/ IBC



















6. All requested changes must be made to the Development Plan and Landscape Plan. DS 2-07.2.1.A

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.

RESUBMITTAL OF THE FOLLOWING ITEMS IS REQUIRED: revised development plan.
06/30/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D06-0018 ROOFSAVERS YARD/REVISED DEVELOPMENT PLAN
DATE: June 28, 2006



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

NOTE:

1: Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved
Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima
County Addressing prior to assignment of addresses.

2: All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.







jg
06/30/2006 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D06-0018 Roofsavers Yard 06/19/06

() Tentative Plat
(X) Development Plan
() Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-75-59

NEIGHBORHOOD PLAN: Arroyo Chico Area Plan

GATEWAY/SCENIC ROUTE: Gateway (Palo Verde Blvd.)

COMMENTS DUE BY: July 17, 2006

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
(X) No Additional Comments – City Attorney’s Office (Michael McCrory) reviewed rezoning condition pending and determined it does not apply anymore, therefore, DP Complies Submitted on: May 25, 2006
07/04/2006 ELIZABETH EBERBACH ENGINEERING REVIEW Approved DATE: July 4, 2006
TO: Patricia Gehlen; CDRC Coordinator
SUBJECT: Roofsavers Yard Development Plan resubmittal Engineering Review
LOCATION: T14S R14E Section 21
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: D06-0018

SUMMARY: The revised Development Plan sheets, landscape plan, setback documentation, and response letter and were received and reviewed by Engineering. Engineering has reviewed the received items and recommends approval of the Development Plan. A Site Plan application and any other building permits required by other departments or sections will be necessary for construction activity. After final approval of the Development Plan, this project will need to be walked through for yellow card / site plan approval. If you have any questions, please call me at 791-5550 extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
07/14/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 14, 2006

Joe Locke
Landlocked Properties
7540 East La Cienega Drive
Tucson, Arizona 85715

Subject: D06-0018 Roofsavers Yard Development Plan

Dear Steve:

Your submittal of June 19, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Development Plan (Landscape, Zoning, DSD)

3 Copies Revised Landscape Plans (Zoning, Landscape, DSD)




Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 628-3705