Permit Number: D06-0013
Parcel: 141180080

Review Status: Completed

Review Details: REVISION - DEV PLAN

Permit Number - D06-0013
Review Name: REVISION - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/02/2008 PAUL MACHADO ENGINEERING REVIEW Approved
01/04/2008 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond Document the location of and the recording information for the Shopping Center Restriction and Easement Agreement on the Development Plan.
01/07/2008 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D06-0013 HOUGHTON TOWN CENTER/REVISED DEVELOPMENT PLAN
DATE: January 7, 2008



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

NOTE:

1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.

2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.





jg
01/08/2008 HEATHER THRALL ZONING REVIEW Denied ,CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Heather Thrall
Senior Planner

PROJECT: D06-0013
Houghton Town Center Retail Development
SW corner of Houghton and Old Vail
Development Plan

TRANSMITTAL DATE: January 8, 2008

DUE DATE: January 8, 2008

COMMENTS:

1. The Zoning Review Section found several changes to this project, including the several new buildings, adjustments in last approved building sizes, PAAL relocations, parking, bike parking and loading calculation changes - etc. Due to the expansive size of this project, the sheer volume of changes and their complexity, zoning staff is unable to review this plan until an extensive, detailed list explaining all changes -by both development criteria (parking, FAR, loading, etc.) AND listed changes sheet by sheet - is provided. This coming review will then be a full review rather than a core review, and will require fees for the additional acreage noted in the newly submitted development plan. Please be sure to provide all new Scenic Corridor Overlay sheets with the changes to view sheds, etc.

Please contact Patricia Gehlen at 520-879-4919 or Patricia.Gehlen@tucsonaz.gov for futher advisement on how to proceed with this project, and whether the Scenic Corridor Overlay case file will need to have further processing as well.




If you have any questions about this transmittal, please call (520) 791-5608.


C:\planning\cdrc\developmentplan\D06-0013 houghton town center 6 OUT.doc
01/08/2008 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
01/11/2008 ANDY VERA ENV SVCS REVIEW Denied 1. DP3 - Triangle raised medians appear restrictive and do not provide adequate turning radii's within ingress/egress for service vehicle. DS 6-01.3.1.A.

2. DP4 - Buildings 21 thru 28 appear to designate for roll-off refuse/recycle compactors. Does not provide the required minimum 14 ft x 40 ft clear approach to enclosure area with adequate maneuverability. DS 6-01.4.1.C.
Also, key note 9 states "trash compactor as required". Must clarify what type of service is going to be provided to these buildings in order to determine if sufficient. If roll-off compactors is the service type then must identify design criteria and annotate requirements appropriately. Refer to DS 6-01.4.3

3. DP5 - Enclosures are positioned so they impede the continous flow of traffic for collection vehicle.
DS 6-01.4.1.H.
Also, building 29 does not provide the required minimum 14 ft x 40 ft clear approach to enclosure area with adequate maneuverability. DS 6-01.4.1.C.

4. DP6 - Buildings 17, 18, & 19 enclosures are positioned so they impede the continous flow of traffic for collection vehicle. DS 6-01.4.1.H. Buildings 14 & 15 enclosures need to be moved back 5 ft to allow for adequate maneuverability and approach.

5. DP7 - Enclosures are positioned so they impede the continous flow of traffic for collection vehicle.
DS 6-01.4.1.H.
Buildings 6, 7, & 9 enclosures do not provide the required minimum 14 ft x 40 ft clear approach to enclosure area with adequate maneuverability. DS 6-01.4.1.C.
Building 8 enclosure needs to be moved 3 ft to the right to eliminate potential conflict with parking spaces/vehicles.

6. Identify refuse/recycle service vehicle circulation throughout development without impeding continuous flow.

7. DP20 - Double and single trash enclosure detail must call out all dimensions within enclosure design. Spacing between bollards and between bollards and CMU wall. Include 10 ft clear from face of enclosure wall to rear wall bollards.
Also, must identify position of cane bolt sleeves for securing the gates in the open position. DS 6-01.4.2.C.4. Recommend installing post at face of each side of enclosure to mount gates on to allow for minimum 12 ft gate opening and 10 ft clear svc area.

Please provide corrections on resubmittal.

If you have any questions you may contact Andy Vera at (520) 791-5543 ext 1212 or e-mail: Andy.Vera@tucsonaz.gov
01/16/2008 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

January 16, 2008

Thomas Saylor Brown, AIA
Sayler-Brown Bolduc, Lara Architects, LLC
1001 North Alvernon Way, Suite 105
Tucson, Arizona 85711-1019

Subject: D06-0013 Houghton Town Center Revised Development Plan

Dear Thomas:

Your submittal of December 7, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval of the Development Plan is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed.

ALL BLUELINES MUST BE FOLDED

13 Copies Revised Development Plan (CORE reviewers, Real Estate, Parks and Recreation, DSD)

7 Copies Revised Landscape Plans (CORE reviewers, Parks and Recreation, DSD),

Please note that the last submittal did not include a detailed list of the proposed revisions so any agencies that approved the last submittal will need to see the plan again. Please add a comment to the letter that details the proposed changes stating that the originally approved plans are available on line so they are not included in this distribution. Fee's, per our e-mail discussion, are also required.

Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 620-0535
12/07/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
12/12/2007 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond December 12, 2007

To: Thomas Sayler-Brown
Sayler-Brown Bolduc Lara Architects

Thru: Patricia Gehlen, CDRC Manager
City of Tucson Development Services Department

___________________________
From: Tom Porter, Sr. CEA (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environment Quality

Subject: Houghton Town Center
DP REVISION - 1st Submittal
D06-013


The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.

Sheet 15: Call out all of the proposed public manholes and include the rim and invert elevations.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above-mentioned comments, please contact me.
12/19/2007 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D06-0013 Houghton Town Center

() Tentative Plat
(XXXX) Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: Annexation C9-84-84, Ordinance 6143

NEIGHBORHOOD PLAN: Esmond Station

GATEWAY/SCENIC ROUTE: Scenic Route - Houghton

COMMENTS DUE BY: 1/08/08

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
(XXXX) Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other –

REVIEWER: drcorral 791-4505 DATE: 12/14/07
12/21/2007 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Denied 4350 E. Irvington Road, Tucson, AZ 85714
Post Office Box 711, Tucson, AZ 85702


WR# 191367 December 19, 2007



SBBL Architecture & Planning
Attn: Ernie Duarte
1001 N Alvernon Way #105
Tucson, Arizona 85711

Dear Mr. Duarte:

SUBJECT: Houghton Town Center
D06-0013

Tucson Electric Power Company (TEP) has reviewed the plan submitted December 12, 2007. TEP is unable to approve the plan at this time. There are existing electrical facilities within the boundaries of this project that must be identified on the Development plan. This includes, but not limited to existing overhead and underground electric lines, utility poles, and pad mounted equipment. In order for TEP to approve the plan the facilities and easements must be depicted on the plans.

Enclosed is a copy of a TEP facility map showing the approximate location of the existing facilities. All costs associated with the relocation of the facilities in conflict will be billable to the developer.

Please resubmit two revised bluelines to City of Tucson Development Services Department for TEP’s review. You may contact the area Designer, Steve Garcia at 917-8739 should you have any technical questions.

Sincerely,



Henrietta Noriega
Office Specialist

hn
Enclosure
cc: CDRC Office, City of Tucson - (by e-mail)
A. Turner, Houghton Commerce - Letter only
S. Garcia, Tucson Electric Power
12/26/2007 JIM EGAN COT NON-DSD FIRE Approved