| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/14/2009 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 01/21/2009 | DAVID RIVERA | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: D06-0012 Associates in Women's Health Development Plan - Revision TRANSMITTAL DATE: January 21, 2009 DUE DATE: January 29, 2009 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 2. Revision note one: The drawing does not depict the relocated class two bicycle parking facilities clearly enough. Add a detail drawing specific to the location and include dimensions or depict the bicycle parking facility clearly. 3. Revision note three: Cloud and add a delta for the staircase revision. 4. Revision note four: It is not clear per your revision note which sidewalk is revised. Be clear on the plan what delta is used for this revision note and annotate the sidewalk(s) with the appropriate delta. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. C:\planning\cdrc\developmentplan\D060012dpca.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan to include all necessary changes |
| 01/21/2009 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Approved | |
| 01/23/2009 | RONALD BROWN | ZONING HC SITE | REVIEW | Approved | |
| 01/26/2009 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | January 26, 2009 D06-0012 Revision The Engineering Division Recommends approval of this revision to the Development Plan. |
| 02/02/2009 | ANDY VERA | ENV SVCS | REVIEW | Approved | |
| 02/05/2009 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES February 5, 2009 Kevin Marrow GDA Southwest, LLC 250 South Craycroft Road, Suite 200 Tucson, Arizona 85711 Subject: D06-0012 Associates in Womens Health Revised Development Plan Dear Kevin: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per the on-line comments, please submit the following documents for sign-off. 1 Rolled blueline COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). Please include applicable sheets from any other concurrent reviews. AND 1 Rolled blueline set of the Development Plan. AND 1 CD that contains all of the drainage/hydrology and other reports submitted for the review and approval of this plan. The extra rolled blueline set that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the rolled bluelines to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.tucsonaz.gov/dsd/CDRC___Rezoning/CDRC/CDRC_Stamp/cdrc_stamp.html. BLUELINE SETS THAT DO NOT HAVE THE STAMP WILL BE RETURNED FOR CORRECTION. Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 881-4390 dpapproved |