Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D06-0012
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/07/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/13/2006 | JCLARK3 | ENV SVCS | REVIEW | Approved | |
| 07/17/2006 | PETER MCLAUGHLIN | LANDSCAPE | REVIEW | Approved | |
| 07/19/2006 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | July 18, 2006 TO: Kevin Morrow GDA Southwest, LLC THRU: Patricia Gehlen City of Tucson, Development Services Department FROM: Dickie Fernández, E.I.T. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: Associates In Womens Health Care Development Plan – 2nd Submittal D06-0012 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. SHEET DP2. Show all existing private sewers including all existing BCSs. Label them with their respective sizes. SHEETS DP2 & C2.0. The information shown on these two sheets do not seem to match. Please revise these sheets as necessary so that the information is accurately reflected on both of them. We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents. The next submittal of this project will be the 3rd submittal. A check for the review fee of this submittal in the amount of $78.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter. For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above mentioned comments, please contact me. Sincerely, Dickie Fernández, E.I.T. Telephone: (520) 740-6947 Copy: Project |
| 07/19/2006 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D06-0012 Associates in Women’s Health 07/18/06 () Tentative Plat (XXXX) Development Plan (XXXX) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: C9-79-68 NEIGHBORHOOD PLAN: Arcadia-Alamo GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 08/04/06 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached (XXXX) No Additional Comments - Complies With Planning Comments Submitted on: 04/25/06 () Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan () Other REVIEWER: D. Estolano 791-4505 DATE: 07/17/06 |
| 08/10/2006 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: ASSOCIATES IN WOMEN'S HEALTH: RESUBMITTAL D06-0012 Tucson Electric Power Company has reviewed and approved the development plan submitted July 7, 2006. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Ms. Mary Boice, Project Manager Design/Build - DB 101 Tucson Electric Power Company P. O. Box 711 Tucson, AZ 85702 (520) 917-8732 Please call the area Field Technician, Steve Garcia at 917-8739, should you have any questions. Sincerely, Denise Tellez Scheduling Coordinator Design/Build dt Enclosures cc: P. Gehlen/F. Rodriguez, City of Tucson (by e-mail) S. Garcia, TEP |
| 08/16/2006 | KAROL ARAGONEZ | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D06-0012 Associates in Women's Health Resubmittal TRANSMITTAL DATE: July 07, 2006 DUE DATE: August 4, 2006 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Please correct the LUC Sec. quoted for Outpatient Service in Code Review Note 4 from 3.4.5.8.B to 3.5.4.8.B 2. Please add a note to the plans listing the type of document that provides the cross access, parking, and pedestrian circulation. Add the recordation information (docket and page number) of the document. DS 2-05.2.3.B 3. Notes indicating compliance to 3.05.2.2.B.2 could not be verified. Add a detail drawing that demonstrates that the structures used for the covered parking comply with the development standards setback from PAALs as listed in development standards 3-05.2.2.B.2. 4. The second loading zone to the southwest of the future building is not labeled. Please label and dimension the loading space. The PAAL adjacent to the space to the west must also be dimensioned to assure that the minimum PAAL width of twenty-four (24) feet maintained. Also correct the Code Review note 13, loading zone to reflect that two (2) spaces are required and two (2) are provided. DS 2-05.2.4.O 5. The detail 8 only demonstrates compliance to parking standards for those spaces abutting a pedestrian walkway (sidewalk). Please provide an additional detail that dimensions a standard vehicle parking space not utilizing a sidewalk area. Dimension the wheel stop from the front of the parking space to the tire side of the wheel stop, (2.5 feet). DS 3-05.2.3 6. Please submit a copy of the list of the current tenants of the entire shopping center to verify existing uses. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550. KAA C:\planning\cdrc\developmentplan\D06-0012dpr.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and any additional requested documents. |
| 08/28/2006 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | DATE: August 28, 2006 To: Patricia Gehlen CDRC/Zoning Manager FROM: Loren Makus, EIT Engineering Division SUBJECT: Associates in Women's Health Care Development Plan D06-0012 (Second Review) T13S, R14E, Section 05 RESUBMITTAL REQUIRED: None The Engineering Divisions has reviewed this Development Plan and recommends approval. If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov. Loren Makus, EIT Senior Engineering Associate |
| 08/30/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES August 30, 2006 Kevin Morrow GDA Southwest, LLC 290 South Craycroft Road #200 Tucson, Arizona 85711 Subject: D06-0012 Associates in Women's Heath Care Development Plan Dear Kevin: Your submittal of July 7, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval of the Development Plan is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed. ALL BLUELINES MUST BE FOLDED 3 Copies Revised Development Plan (Wastewater, Zoning, DSD) 2 Copies Revised Landscape Plans (Zoning, DSD), Should you have any questions, please call me at 791-5608, ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 881-4390 |