Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: D06-0011
Parcel: 11449037H

Review Status: Completed

Review Details: DEVELOPMENT PLAN

Permit Number - D06-0011
Review Name: DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/27/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/03/2006 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved NO COMMENT
D06-0011
DOWL ENGINEERS
VILLAS AT TANQUE VERDE
*********************************************************************
Confidentiality and Nondisclosure Notice: This email transmission
and any attachments are intended for use by the person(s)/entity(ies)
named above and may contain confidential/privileged information.
Any unauthorized use, disclosure or distribution is strictly
prohibited. If you are not the intended recipient, please contact the
sender by e-mail, and delete or destroy all copies plus
attachments.
*********************************************************************
04/06/2006 JCLARK3 ENV SVCS REVIEW Approved * No known landfill with in 1000 feet of this development.
* No recycling provisions shown or reference to recycling.
* Dumpster enclosure can be serviced but it requires the service vehicle to go opposite to the flow of traffic. Recommend that the enclosure be constructed perpendicular to the cul-de-sac. This would allow direct front loading service and the truck can operate with the flow of the traffic. The enclosure could also be made into a double enclosure which will proivide recycling for the complex.
04/07/2006 TIM ROWE PIMA COUNTY WASTEWATER Denied April 5, 2006

TO: Rudolf A. Ing, P.E.
DOWL Engineers

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Villas at Tanque Verde
Development Plan – 1st Submittal
D06-0011


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Provide a letter from PCWWM Planning Services, written within the past 90 days, stating that treatment and conveyance system capacity for this project is available. A capacity request form may be found at http://www.pima.gov/wwm/forms/docs/CapResponseRequest.pdf.

ALL SHEETS. Add the project number, D06-0011, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers.

Based on the evaluation of the proposed sewer design, this project qualifies for Standard sewer connection fee rates.

This project proposes off-site sewers that will travel across private property. Please clearly explain how the project owner intends to do this. Provide any supporting documentation that may be relevant including written permission from the property owners involved.

The comments below are being provided without knowing if the project proposes public off-site or private off-site sewers.

SHEET 1. Add the following General Note and fill in the blanks appropriately.

THIS PROJECT HAS ____ PROPOSED AND ____ EXISTING WASTEWATER FIXTURE UNIT EQUIVALENTS, PER TABLE 13.20.045(E)(1) IN PIMA COUNTY CODE 13.20.045(E).

SHEET 1. Add the following General Note

ON-SITE SANITARY SEWERS WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT AT THE TIME OF SUBMITTAL OF PLUMBING OR BUILDING PLANS.

SHEET 1. Add the following General Note

ANY WASTEWATER DISCHARGED INTO THE PUBLIC SANITARY SEWERAGE SYSTEM SHALL MEET THE REQUIREMENTS OF THE INDUSTRIAL WASTE ORDINANCE (PIMA COUNTY ORDINANCE NO. 1991-140, AS AMENDED).

SHEET 1. Add the following General Note

MAINTENANCE AND OPERATION OF THE PRIVATE SANITARY SEWER TO ITS POINT OF CONNECTION TO THE PUBLIC SEWER IS THE RESPONSIBILITY OF THE PROPERTY OWNER.

SHEET 1. Add the following Permitting Note

A PROJECT CONSTRUCTION PERMIT MUST BE SECURED FROM PIMA COUNTY
WASTEWATER MANAGEMENT DEPARTMENT BEFORE BEGINNING ANY WORK ON THIS PROJECT.

SHEET 2. Label the existing public manhole on this sheet with its accurate Pima County manhole number.

We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents.

The next submittal of this project will be the 2nd submittal. A check for the review fee of this submittal in the amount of $100.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter.

For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly.





If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
04/10/2006 JIM EGAN COT NON-DSD FIRE Denied Add the following notes to the plan.

1) An approved water supply capable of supplying the projected fire flow for fire protection shall be provided and extended to serve directly any and all subdivded properties.
2) "No Parking - Fire Lane" signs shall be provided as needed to provide 20' clear unobstructed width along all fire apparatus access roadways in accordance with the fire code.
3) On street parking shall be prohibited on both sides and signs shall be installed so indicating.
04/11/2006 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: VILLAS AT TANQUE VERDE
D06-0011

Tucson Electric Power Company has reviewed and approved the development
plan submitted March 27, 2006. It appears that there are no conflicts
with the existing facilities within the boundaries of this proposed
development.

Enclosed is a copy of a TEP facilities map showing the approximate
location of the existing facilities.

In order to apply for electric service, call the New Construction
Department at (520) 918-8300. Submit a final set of plans including
approved site, offsite and electrical load plans. Include a CD with the
AutoCAD version of the plans. If easements are required, they will be
secured by separate instrument. Your final plans should be sent to:

Tucson Electric Power Company
Attn: Ms. Mary Boice
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8732

Please call the area Designer, Nancy DiMaria at (520) 918-8267, should
you have any questions.


Sincerely,



Kathy Clark
Scheduling Coordinator
Design/Build
kc
Enclosures
cc: P. Gehlen, City of Tucson
N. DiMaria, Tucson Electric Power Company


Kathy Clark
Scheduling Coordinator
Design/Build
520-918-8271
kclark@tep.com
04/19/2006 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Add the CDRC case number and any related case numbers to the landscape and native plant preservation plans.
DS 2-07.2.1.B

2) All lettering and dimensions shall be the equivalent of twelve (0.12") point or greater in size. DS 2-05.2.1.A
Revise the native plat preservation plan to comply.

3) Revise the development plan to include the following note, if applicable: "This project is affected by the City of Tucson Floodplain Regulations." DS 2-05.2.2.C.2.a

4) Revise the development plan to include floodplain information, such as the location of the existing 100-year flood limits for all flows of one hundred (100) cfs or more with 100-year flood water surface elevations. DS 2-05.2.3.I

5) The site plan keynotes reference sheet C1.3, however the details appear to be located on sheet 3. Revise as necessary. DS 2-05.2.4.X

6) The landscape plan must include the following grading information per DS 2-07.2.2.B:

A) Percent slope across the site and the direction of the slope of paved areas.

B) Existing grades on adjacent rights-of-way and adjacent sites and proposed finish grades.

C) Limits of grading. Indicate natural contours of undisturbed areas.

D) Areas of detention/retention, depths of basins, and percentage of side
slope or slope ratio.

E) Water harvesting areas.

7) Revise the landscape plan to note the height and materials used to construct required screening elements for refuse storage and any loading areas. DS 2-06.2.2.A.3

8) Revise the development plan and landscape plan to provide a screen wall for the vehicular use areas within 100' of the west property line. Label the wall as indicated above and correct the call-outs as necessary. LUC Table 3.7.2-I

9) The required screen for the vehicular use area must measure at least 5' from the finished grade of the paved areas. Clarify as necessary. DS 2-06.3.7.A.1

10) Revise the native plant preservation plans to show the limits of grading and identify the 30' scenic route buffer area as "to remain natural". DS 2-15.3.4.A

11) Revise the native plant preservation plan to use the correct symbol for #103 on the aerial photo. DS 2-15.3.4.A.4

12) Revise the native plant preservation plan to show the same site layout as the development plan/landscape plan. DS 2-15.3.4.A

13) Applications for projects within the Scenic Corridor Zone (SCZ) shall be reviewed in accordance with the DSD Full Notice Procedure, Sec. 23A-50 and 23A-51. Contact Patricia Gehlen-Zoning Manager for application information. The decision to approve or deny the project will be based on compliance with the purpose, intent, and specific regulations of LUC 2.8.2.

14) Within the 30' scenic route buffer area, indigenous plant material is to remain. Clarify this requirement on the landscape plan. DS 2-06.7.1.B

15) The landscape plan should clarify that decomposed granite will not be allowed in the 30' scenic route buffer area. DS 2-06.7.1.B

16) Revise the irrigation plan to locate the lateral lines so that disturbance in the 30' scenic route buffer area is minimized, if not eliminated. LUC 3.7.5.2.A

RESUBMITTAL OF PLANS IS REQUIRED
04/21/2006 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D06-0011 VILLAS AT TANQUE VERDE/DEVELOPMENT PLAN
DATE: 4/20/06



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

Correct section corners in Location Map (This project borders the east line of Section 33).

Label Tanque Verde Road on sheet 2.

Number buildings numerically.







es
04/24/2006 FRODRIG2 COT NON-DSD REAL ESTATE Approved No comment
04/28/2006 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: April 27, 2006

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov

CC:


SUBJECT: D06-0011 Villas at Tanque Verde: Development Plan(4-27-06)


Staff has no comments.
05/02/2006 PAUL MACHADO ENGINEERING REVIEW Denied To: Patricia Gehlen DATE: May 4, 2006
CDRC/Zoning Manager
SUBJECT: Villas at Tanque Verde, 8640 Tanque Verde Rd.
Development Plan D06-0011 (First Review)
T13S, R15E, Section 33

RESUBMITTAL REQUIRED: Development Plan and Drainage Report.

The Development Plan (DP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Development Plan:

1. Please include a response letter to the comments along with the corrected copies of the DP.
2. As per the Federal ADA requirements, all wheel chair ramps shall have the truncated domes instead of the standard grooves that are shown on COT SD 207. Aside from the Truncated Domes, all wheel chair ramps shall be constructed in accordance with COT SD 207. The Truncated Domes are not located in the correct position. Re-locate the domes to the bottom of the ramp adjacent to the pavement, not on the ramps themselves.
3. Please provide a timetable for completing a CLOMR and/or LOMR for the revision to the federally mapped Tanque Verde Creek. Coordination with Suzanne Shields at the Pima County flood control district, 740-6350, is advised. This review was done assuming the acceptance of the CLOMR and/or LOMR by FEMA. Should the CLOMR be denied or significantly modified form it's present form, a new review will be required.
4. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10. The future SVT's are not shown correctly. Revise as necessary.
5. Show the limits of the 100-year floodplain and water surface elevation per D.S. 2-02.2.1.15.
6. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
7. Location and orientation of existing major physical features, such as railroad tracks and drainageways per D.S. 2-02.2.1.22.
8. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23.
9. Show Development plan number (S06-0011) on all sheets per D.S. 2-02.2.1.29.
10. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0.
11. Placement of fill in excess of 2' above existing grade at any location in the outer 100' of the developing site is not allowed and/or shall meet the requirements per D.S. 11-01. Please address.
12. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
13. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable. State whether the street is public or private and include dimensions. It appears that he width of the road does meet minimum City of Tucson requirements please revise as required.
14. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks including any other site drainage as well. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, a general note indicating sidewalk scuppers will be used when the roof scuppers locations have been designed and located will suffice.
15. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
16. "A grading permit and Stormwater Pollution Prevention Plans (SWPPP's) will be required for this project. Submit 4 sets of grading and SWPPP's with text, upon completion and submittal of a grading permit application. A grading permit may not be issued prior to site plan approval. Subsequent comments may be necessary, depending upon the nature and extent of revisions that occur to the plans".

Drainage Report:
1. Please include a response letter to the comments along with the corrected copies of the DR.
2. This review was performed for Development Plan purposes only. Final review and acceptance will be done at the grading plan stage.
3. Please provide a timetable for completing a CLOMR and/or LOMR for the revision to the federally mapped Tanque Verde Creek. Coordination with Suzanne Shields at the Pima County flood control district, 740-6350, is advised. This review was done assuming the acceptance of the CLOMR and/or LOMR by FEMA. Should the CLOMR be denied or significantly modified form it's present form, a new review will be required.
4. Show the project address or administration address on the cover sheet of the DR.
5. Add the basin(s) maintenance responsibility note and checklist per S.M.D.D.F.M. 2.3.1.6 C 1 and 2 to the DR.

If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@ci.tucsonaz.govs
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
C:/8640 Tanque Verde Rd. DP
05/02/2006 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D06-0011 Villas at Tanque Verde 05/01/06

() Tentative Plat
(XXXX) Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C15-02-03

NEIGHBORHOOD PLAN: General Plan

GATEWAY/SCENIC ROUTE: Tanque Verde

COMMENTS DUE BY: 4/24/06

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(XXXX) Resubmittal Required:
() Tentative Plat
(XXXX) Development Plan
() Landscape Plan
(XXXX) Other – Elevations & Colors

REVIEWER: D. Estolano 791-4505 DATE: 4/28/06
URBAN PLANNING AND DESIGN COMMENTS
D06-0011 - Villas at Tanque Verde
April 28, 2006

The General Plan and the Design Guidelines Manual provide guidance for the review of this development plan

Policy 3: Preserve scenic views of natural features and community landmarks.

Supporting Policy 3.1 Protect views from frequently used gathering places, major streets, and pedestrian paths to provide a sense of place and orientation.




The General Plan states to preserve scenic views of natural features. The Scenic Corridor Zone (SCZ) states building structure surfaces visible from a scenic route shall have colors which are predominant within the surrounding landscape, such as desert and earth tones. Under the Permitting Notes section, Items #5 reads: “This project is subject to Scenic Corridor Zone (SCZ) overlay requirements section Case No. xxxxx. Approved xxxx 2006. Approved colors xxxxxx, conditions: xxxxx.” Please add omitted information.
05/08/2006 DALE KELCH COT NON-DSD TRAFFIC Denied Traffic Engineering REJECTS this DP:

1. Tucson City Code Chapter 25 Section 38 states that the maximum driveway width for adjoining properties is 30'. The two units at the northwest of this plan appear not to meet this requirement.

2. Tucson City Code Chapter 25 Section 38 requires a minimum driveway separation of 12'. The four units at the south of this plan appear not to meet this requirement.

3. List the name, ROW width, recordation data, type and dimensioned with of paving, curbs, curb cuts and sidewalks. (DS 2-05.2.2.D) There is no recordation data for Tanque Verde nor is Tanque Verde labeled on sheet 2.


D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
05/15/2006 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Passed
05/15/2006 PGEHLEN1 OTHER AGENCIES PIMA ASSN OF GOVTS Passed
05/23/2006 TERRY STEVENS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Terry Stevens
Lead Planner

PROJECT: D06-0011
Villas at Tanque Verde
Development Plan

TRANSMITTAL: 05/23/06

DUE DATE: 4\24\06

COMMENTS:

1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is 4/23/07.

ATTENTION: THE USE PROPOSED FOR THIS SITE, RESIDENTIAL CARE SERVICES WITH 90 BEDS ON A SR ZONED PARCEL, FALLS UNDER THE LUC SEC. 2.2.4.3.C.3. THIS USE IS NOT PERMITTED WITHIN THIS ZONE WITH OUT APPROVAL THROUGH THE SPECIAL EXCEPTION PROCESS. THE SPECIAL EXCEPTION PROCESS HAS NOT BEEN APPROVED NOR APPLIED FOR REGARDING THIS SITE. RESUBMITTAL OF THE DEVELOPMENT PLAN WILL NOT BE ALLOWED UNTIL THE SPECIAL EXCEPTION PROCESS HAS BEEN COMPLETED. THE FOLLOWING COMMENTS MAY CHANGE OR BE ADDED TO BASED ON CONDITIONS IMPOSED BY THE SPECIAL EXCEPTION PROCESS. CONTACT DAN CASTRO OR AILENE TORRES REGARDING PROCEDURES FOR THE SPECIAL EXCEPTION PROCESS.

2. DS 2-05.2.2.B.2 This project has been assigned the case number D06-0011. List the case number in the lower right corner next to the title block of all plan sheets including the Landscape and NPPO sheets.

3. This parcel of property, according to Pima County Assessor's records, was split in 2003. Provide documentation that the City of Tucson has approved the lot split.

4. DS 2-05.2.1.D The section lines indicated on the location map are incorrect. Section 33 eastern boundary is also the eastern boundary of the parcel for this proposed development. Please revise.

5. DS 2-05.2.1.K The referenced rezoning and annexation case numbers, indicated on all three pages, are for a rezoning case on River Rd. and an annexation case which does not apply. The annexation case number which does apply is C9-89-2.

6. DS 2-05.2.2.B.3 In the proposed use (note #4) list the subject to section of the LUC for the use. "subject to: Sec. 3.5.7.8.B1, .C2, and D and approval through a Zoning Examiner Full Notice Procedure."

7. DS 2-05.2.2.B Provide a note stating "This project is designed to the overlay zone criteria: Sec. 2.8.2, Scenic Corridor Zone (SCZ); Sec. 2.8.3 Major Streets and Routes (MS&R) Setback Zone."

8. DS 2-05.2.2.B.11 List the gross area of the site by square footage and acreage.

9. DS 2-05.2.3.B All easements shall be drawn on the plan. The recordation information, location, width and purpose of all easements on site will be stated. There appears to be a proposed utility easement from the road through the center of the project. Identify the easement, provide width, recordation information, etc.

10. DS 2-05.2.3.C Provide the name of the adjacent street on the plan.

11. DS 2-05.2.4.B All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined.

12. DS 2-05.2.4.D Parking area access lanes (PAALs), shall be designed in accordance with Sec. 3.3.0 of the LUC and Development Standard 3-05.0.

Clearly indicate the width of all PAALs (one way and two way) through out the project.

A full width PAAL is required for a portion of the vehicular use area serving the two structures which now appear to share a driveway. (Structures located near the southern property line)

13. DS 22-05.2.4.F The indicated future curb location for Tanque Verde Rd. is incorrect. The sidewalk area (back of curb location) for a MS&R with a 150' R.O.W is 12' not 19' as indicated. See engineering comments.

14. DS 2-05.2.4.I All applicable building setback lines, such as SCZ and zoning, including sight visibility triangles, will be shown. On zoning setbacks, if the building is proposed for location at a greater distance from the property line than the required setback, show only the dimension of the distance between the building and the property line. If the setback's point of measurement is not the property line, include the distance from the property line to the point of measurement.

The indicated 30' SCZ setback line along Tanque Verde Rd. is not a setback line. There is a 30' buffer zone required by the SCZ overlay. The required building setback per LUC Sec. 2.8.2.5 is based on the height of the structure. If a 24' tall structure is proposed, the building setback from the front property line then is 72'. Clearly indicate with dimensions the required setback for front setback as well as building setbacks for the perimeter yards adjacent to the different adjacent zoning.

Provide a copy of the floor plan and elevations (with dimensions) of a typical structure. These will be used in the review to verify setbacks and parking requirements.

15. DS 2-05.2.4.K Show on-site pedestrian circulation as required by the LUC utilizing location and design criteria in Development Standard 2-08.0.

Provide a pedestrian circulation path (sidewalks) from the right of way connecting to the sidewalks for the project. Sidewalks and handicap ramps may be required in the right of way. If they are required then the pedestrian circulation path for the project must connect to the sidewalks in the right of way See engineering comments.

Provide a pedestrian circulation path (sidewalks) to all entrances of the proposed structures. These sidewalks must connect to the pedestrian circulation path for the entire project.

The crosswalk indicated at the refuse container location will not be allowed. The sidewalk must be provided around the refuse container location.

Sidewalks are required between a PAAL and a building. Missing for the units located in the southeast corner of the lot and the two units in the northwest side of the lot which appear to share a driveway.

The truncated domes indicated in details 2 of 3 and 3 of 3 are not located correctly. The truncated domes are to be adjacent to the vehicular use area, at the head of the access aisle and at the foot of the handicap ramp when the ramp is adjacent to a vehicular use area. Indicate that the truncated domes will be a minimum of 24" in width.

16. DS 2-05.2.4.N On the drawing, show the location and footprints of all structures. Label the heights and dimensions.

17. DS 2-05.2.4.O Clearly indicate on the drawings the location and size of the required loading zones.

Indicate vehicular maneuverability for ingress/egress to each of the loading zones.

18. DS 2-05.2.4.P Provide a dimensioned layout detail for the parking spaces located along the radius portion of the PAAL at the southern end of the vehicular use area.

Provide a detail of the required handicap parking space and van accessible handicap parking space signage.

19. DS 2-05.2.4.Q The bicycle parking spaces as indicated do not appear to be visible from the adjacent street. Therefore directional signage is required. Indicate location of the required signage.

20. DS 2-05.2.4.U Indicate graphically, where possible, and by notes, in all other instances, compliance with conditions of the Special Exception process.

21. DS 2-05.2.4.V Indicate location and type of postal service to assure there are no conflicts with other requirements, such as pedestrian accessibility, utilities, and landscaping.

22. DS 2-05.2.4.W If applicable, indicate the locations and types of proposed signs (wall, free-standing, pedestal, and billboards)to assure there are no conflicts with other requirements and that minimal locational requirements can be met.

If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000.

TLS C:\planning\cdrc\developmentplan\D06-0011dp.doc
05/24/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

May 24, 2006

Rudolf A. Ing, P.E.
DOWL Engineers
166 West Alameda
Tucson, Arizona 85701

Subject: D06-0011 Villas at Tanque Verde Development Plan

Dear Rudolf:

Your submittal of March 27, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval of the Development Plan is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed.

ALL BLUELINES MUST BE FOLDED

9 Copies Revised Development Plan (Fire, Addressing, Wastewater, Landscape, Community Planning, Engineering, Traffic, Zoning, DSD)

5 Copies Revised Landscape Plans (Landscape, Community Planning, Engineering, Zoning, DSD),

2 Copies Revised NPPO Plans (Landscape, DSD)

2 Copies Revised Drainage Report (Engineering, DSD)

2 Copies Colors and Elevations (Community Planning, DSD)


Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 624-0384