Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D06-0003
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/12/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 05/22/2006 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Revise the landscape plan and native plant preservation plans as necessary to meet the minimum preservation requirements of LUC 3.8.6.2.A.3. At least thirty (30) percent of viable Cercidium microphyllum shall be preserved-in-place or salvaged and transplanted on-site*. * Per DS 2-15.6.A "Grading and construction that encroaches into the required root zone may be allowed on a case-by-case basis as determined by the Landscape Inspector depending upon the size and species of the Native Plant. 2) Revise the planting plan to correct the symbol for one of the two types of groundcover used. |
| 05/22/2006 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | May 19, 2006 TO: Gary Gretcher Gretcher Designs LLC THRU: Patricia Gehlen City of Tucson, Development Services Department FROM: Dickie Fernández, E.I.T. Pima County Development Services Department Development Review Division (Wastewater) SUBJECT: Northwest Corner of Harrison & Old Spanish Trail Development Plan – 3rd Submittal D06-0003 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. SHEET 2. Existing manhole 2 is existing, please label it as such. It is not required to show the information beyond its rim and invert elevation and plan number . SHEET 2. The proposed private sewer layout is not clear and requires further revision. Show the size, length and slope for the proposed private sewers. Show how the sewer is connecting to existing manhole 2. Show the rim and invert elevation for any cleanouts. Place a cleanout at any location where there is a change in alignment. We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents. The next submittal of this project will be the 4th submittal. A check for the review fee of this submittal in the amount of $39.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter. For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly. If you have any questions regarding the above mentioned comments, please contact me. Sincerely, Dickie Fernández, E.I.T. Telephone: (520) 740-6947 Copy: Project |
| 05/25/2006 | JCLARK3 | ENV SVCS | REVIEW | Approved | |
| 06/05/2006 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | Re: revised Development Plan The Development Plan is approved. No additional submittals are required. Thanks. ****************************** Joanne Hershenhorn Lead Planner City of Tucson Department of Urban Planning and Design 345 E. Toole Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-4505 joanne.hershenhorn@tucsonaz.gov www.cityoftucson.org/planning |
| 06/12/2006 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 07/21/2006 | TERRY STEVENS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Terry Stevens Lead Planner PROJECT: D06-0003 Village Square Development Plan TRANSMITTAL: 07/21/06 DUE DATE: 6/12/06 COMMENTS: 1. The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 2. In the parking calculations, "General Sales" parked at 1/200 for 6700 GFA totals to 33.5 spaces required. Per LUC Sec. 3.3.3.8 fractional amounts equal to or greater than one half are rounded up to the next whole number. Revise required parking spaces for the General Sales to 34, the total to 165, the 90% mixed use to 149, parking spaces required to 149 and the excess parking provided to 10 spaces. If you have any questions about this transmittal, please call Terry Stevens, (520) 791-5550 ext. 2000. C:\planning\cdrc\developmentplan\D06-0003dpca.doc |
| 07/25/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES July 25, 2006 Gary Cretcher Cretcher Designs LLC 12031 East Quesada Place Tucson, Arizona 85749 Subject: D06-0003 Village Square Development Plan Dear Gary: Your submittal of May 12, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed. ALL BLUELINES MUST BE FOLDED 3 Copies Revised Development Plan (Wastewater, Landscape, DSD) 2 Copies Revised Landscape and NPPO Plans (Landscape, DSD) Should you have any questions, please call me at 791-5608, ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 760-4539 |