Permit Number: D06-0002
Parcel: 13623009B

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D06-0002
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/06/2007 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/19/2007 JOE LINVILLE LANDSCAPE REVIEW Denied 1) The vehicular use area must be provided with post barricades or wheel stop curbing designed to prevent parked vehicles from extending beyond the property lines; damaging adjacent landscaping, walls, or buildings and to prevent vehicles from driving onto unimproved portions of the site per DS 3-05.2.3.C. Revise the plans as necessary to provides a barrier at the perimeter of the vehicular use area.

2) Revise the section designators on sheet 4 of the development plan to refer to the correct sheet numbers. The details are on sheet 5, not 6.

3) Revise the references to the Standard Detail for the concrete header to cite the correct number under Keynotes on sheet 3 of the development plan.
11/26/2007 JOSE ORTIZ COT NON-DSD TRAFFIC Approved
11/27/2007 FRODRIG2 PIMA COUNTY WASTEWATER Approved November 6, 2007

TO: Steven Hill, P.E.
Leadstar Engineering

THRU: Patricia Gehlen, CDRC Manager
City of Tucson, Development Services Department

FROM: Tom Porter ,Sr. CEA
Development Review Division (Wastewater)
Pima County Development Services Department

SUBJECT: Esperanza El Escalante
Development Plan – 3rd Submittal
D06-002


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan as submitted.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me.

Sincerely,



Tom Porter
Telephone: (520) 740-6579

Copy: Project File
11/27/2007 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D06-0002 ESPERANZA EL ESCALANTE/REVISED DEVELOPMENT PLAN
DATE: November 27, 2007



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

NOTE:

Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.

2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.



jg
12/03/2007 ANDY VERA ENV SVCS REVIEW Approved Access and maneuverability good. Propsed dumpster sites will work.
12/03/2007 HEATHER THRALL ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Heather Thrall
Senior Planner

PROJECT: D06-0002
Esperanza el Escalante
3700 S. Calle Polar

TRANSMITTAL DATE: December 3, 2007

DUE DATE: December 6, 2007

1. (last/this review) Per DS 2-05.2.2.B.5, Thank you for providing Lot Coverage calculations on sheet 1. As the Special Exception case allows up to 50% lot coverage, place the following note next to development designator 9 " Special Exception subject to 3.5.7.8. B.1, C.4, D & G; which allows a maximum of 50% lot coverage." Please provide the actual proposed lot coverage in percentage, as well. ( I see the square footage, thank you.)

2. (last review) Per DS 2-05.2.2.B.2, list SE-03-08 case requirements- see note 29.
I see listed conditions, thank you. As it is unclear how criteria will be met, please note that in future reviews, a complete full code compliance review for future phases is required. Provide a note on the plan that states that "the next phase of development must be phase A-2, requiring the entire development to meet full code compliance."

3. (Per this review) this submittal consists of 5 pages of development plan. There are several notations that need to be updated to reflect only 5 pages are submitted, not 6 as before. Please check all notes and references to details on all 5 pages and revise.

4. (last review) Per DS 2-05.2.4.K, regarding pedestrian/handicapped access:
A) (last review) Provide a sidewalk between new parking spaces and existing buildings57 and 58 - 4' wide, DS 2-08. Note, a DSMR (Development Standard Modification Request) is required for less than 4' wide. Zoning can support a minimum of 3'wide sidewalk.
B) (this review) A connection from wheel chair ramps to the sidewalk near the existing patio at the new buildings must be provided. The wheel chair ramps lead to landscape area.
C) (this review) On detail 10 on sheet 5, handicapped sign will be damaged with it's location directly behind the wheel stop barrier. Recloate the handicapped signage. The wheel stop barrier allows a 2.5' car overhang. The last review had handicapped signage in the 4' wide mandatory clear area for the sidewalk -ensure when you relocate the sign that it does not interfere again with the required pedestrian clearance.

5. Depending upon the responses provided, further review comments may be forthcoming. Should you have questions on this review, contact me at Heather.Thrall@tucsonaz.gov or at 791-4541x1156. If you want to meet with me, I would welcome that, prior to a resubmittal.

If you have any questions about this transmittal, please call (520) 791-5608.


C:\planning\cdrc\developmentplan\D06-0002 esperanza el escalante 3.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, additional requested documents.
12/07/2007 LAITH ALSHAMI ENGINEERING REVIEW Approved Laith Alshami, Engineering and Floodplain Review, 12/07/2007,

TO: Patricia Gehlen FROM: Laith Alshami, P.E.
CDRC Engineering

SUBJECT: Esperanza El Escalante
D06-0002, T14S, R15E, SECTION 30

RECEIVED: Development Plan, Landscape Plan and Drainage Report on November 06, 2007

The subject project has been reviewed. The revised Development and Landscape Plans are recommended for approval pertaining to Engineering and Floodplain. Please be advised that additional information might be required on the grading plan.
12/07/2007 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

December 7, 2007

Steve Hill
Leadstar Engineering
1010 North Finance Center Drive, Suite 200
Tucson, Arizona 85710

Subject: D06-0002 Esperanza El Escalante Development Plan

Dear Steve:

Your submittal of November 6, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Development Plan (Landscape, Zoning, DSD)

3 Copies Revised Landscape Plans (Zoning, Landscape, DSD)





THE TWO YEAR REVIEW PERIOD FO R THIS PLAN WILL EXPIRE JANUARY 17, 2008. IF APPROVAL IS NOT RECEIVED BY THIS DATE, NEW REVIEW FEES AND A NEW CASE NUMBER WILL BE REQUIRED PRIOR TO FURTHER REIVEW.


Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/