Permit Review Detail
Review Status: Completed
Review Details: REVISION - DEV PLAN
Permit Number - D05-0034
Review Name: REVISION - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/10/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 05/15/2007 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | May 11, 2007 To: Peter Salonga, Otracle Engineering Group Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department ____________________________________ From: Tom Porter(520-740-6579), representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: World Savings Development Plan – 5th Submittal D05-0034 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Sheet 2: Two of the cleanouts are marked as CO #1, please revise. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan. The required revision(s) may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter CC: Project File |
| 05/22/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | 1) Prepare the trail easement referred to on the plans. Obtain City of Tucson acceptance prior to recording. No Certificate of Occupancy will be issued until the easment is accepted by the City of Tucson and recorded. 2) A minimum distance of two (2) feet must be maintained between a PAAL and any wall, screen, or other obstruction. Revise the plans to locate the required screen along Harrison Road as required by DS 3-05.2.2.B.2. Refer to LUC 3.7.3.2.C for limitations on locating screening with the street landscape border. RESUBMITTAL OF AL PLANS IS REQUIRED |
| 05/31/2007 | JOSE ORTIZ | COT NON-DSD | TRAFFIC | Approv-Cond | Call out for 25' radius curb returns. |
| 05/31/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D05-0034 World Savings Development Plan TRANSMITTAL DATE: May 30, 2007 DUE DATE: June 8, 2007 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Please include the contour interval on each sheet of the development plan with the north arrow. DS 2.05.2.1.H 2. The separate response letter detailing compliance to applicable rezoning conditions of C9-00-03 does not provide must detail as to how compliance to rezoning conditions was accomplished. For example for rezoning condition 9a the response would state a copy of the required report was provided to the president of the "X" Neighborhood for review on April 10th. Please provide a detailed response letter. DS 2-05.2.4.U 3. Please label drive-through lane being serviced by the ATM as "ATM Service Only" on the development plan. 4. Please revise bicycle detail 1 showing proposed class 2 bicycle parking spaces. The required spacing between bicycle parking space must be a minimum of thirty (30) inches. The type of rack proposed does not provide two-point support for bicycles. The rolling rack is an unacceptable design since it does not provide for two-point support. Bicycle can easily fall over and damage. Please review DS 2-09.8.0 Figure 2 - 7 for acceptable and unacceptable rack designs and Figure 9 for dimensional requirements. DS 2-09.5.1, DS2-09.5.2, DS 2-09.5.4, & DS 2-09.6.2 5. The proposed monument sign proposed on 22nd Street appears to be placed within the future sight visibility triangle. Lines of sight cannot be obscured between thirty (30) inches and six (6) feet through a triangle area adjacent to a driveway, a PAAL, or a street, where such access ways intersect with another street in a T-configuration. Please revise location of proposed monument sign. DS 3-01.5.1.A.1 6. The PAAL on the east side is dimensioned as twenty-three and one half (23 1/2) feet. The minimum width allowed for a two-way PAAL is twenty-four (24) feet. Please revise. DS 3-05.2.1.C.1 7. Please dimension the PAAL on the west side of the building. 8. Please demonstrate that a delivery vehicle can maneuver around the southwest corner of the site without having to cross into the required stacking area. The radius is based on the national standards for turning radii required for vehicles for which the loading space is designed. LUC 3.4.4.2.C 9. Please revise wording used in bicycle parking calculations. It should read 8% of "provided" vehicle parking, not required, and the calculation should be 0.08x"25", not 24. LUC 3.3.3.5 10. The dumpster location is within fifty (50) feet of R-1 zoned property (common area "A", Harrison Terrace). Per rezoning condition 19 all dumpsters are to be placed at least fifty (50) feet from residentially zoned or developed property. Please revise location. C9-00-03 Condition 19 11. All changes, modifications, and/or corrections must be made on all applicable plans including the development plan, landscape plan, and NPPO. Once changes, modifications, and/or corrections are made and reviewed further comments may result. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960. KAA S:\zoning review\karol\planning\cdrc\developmentplan\D05-0034dpr1.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and additional requested documents. |
| 06/11/2007 | SUNRISE ENGINEERING | ENGINEERING | REVIEW | Denied | June 7, 2007 City of Tucson 201 N. Stone Ave. Tucson, Arizona 85726 RE: Plan Review: World Savings- 9484 E 22nd St. Applicant: Steven Miller Sunrise Engineering’s Civil Engineering Plan Review Team has completed the 4th review of the following documents on behalf of the City of Tucson Development Services Department: Plans: One (1) copy (5 sheets) with cover sheet dated April 5, 2006. These documents were not reviewed since these are not the newer, revised plans. Drainage Report: One (1) report, dated May 7, 2007. All the drainage report comments were addressed. At this time we do not recommend approval. If you have any questions regarding these comments, please contact the reviewer Stephanie Schramm at 520-723-8634, between 8:00 A.M. and 5:00 P.M., Monday through Friday. Sincerely, SUNRISE ENGINEERING, Civil Engineering Plan Review Team Stephanie Schramm, P.E. Project Manager |
| 06/13/2007 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D05-0034 World Savings 06/13/07 () Tentative Plat (X) Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: C9-00-03 NEIGHBORHOOD PLAN: Pantano East Area Plan GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY: June 8, 2007 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached (X) No Additional Comments - Complies With Planning Comments from 12/26/06. REVIEWER: msp 791-4505 DATE: June 8, 2007 |
| 06/21/2007 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | DATE: June 21, 2007 TO: DSD_CDRC@ tucsonaz.gov FROM: Glenn Hicks Parks and Recreation 791-4873 ext. 215 Glenn.Hicks@tucsonaz.gov SUBJECT: D05-0034: World Savings: Development Plan Review(5-10-07) Approved. |
| 07/11/2007 | CDRC1 | COT NON-DSD | REAL ESTATE | Approved | Re: D05-0034 World Savings |
| 07/12/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES July 12, 2007 Steve Miller World Savings 1901 Harrison Street Oakland, CA. 94612 Subject: D05-0034 World Savings Revised Development Plan Dear Steve: Your submittal of May 10, 2007 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 6 Copies Revised Development Plan (Traffic, Landscape, Wastewater, Zoning, Engineering, DSD) 4 Copies Revised Landscape Plans (Zoning, Landscape, Engineering, DSD) Should you have any questions, please call me at 791-5608, ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 510-446-4509 & 292-6144 (attn: Pete Salonga) |
| 07/12/2007 | PGEHLEN1 | POLICE | REVIEW | Passed |