Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D05-0034
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/10/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 03/14/2006 | TIM ROWE | PIMA COUNTY | WASTEWATER | Approv-Cond | March 14, 2006 To: Andy Timberg, Richard-Bauer Architects Thru: Patricia Gehlen, CDRC Project Manager City of Tucson Development Services Department ____________________________________ From: Michael Harrington (520-740-6579), representing the Pima County Departments of Wastewater Management and Environmental Quality Subject: World Savings Development Plan - 3rd Submittal D05-0034 The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Our office has received the required capacity response letter for our file. Sheet DP2.0: Item 44. in the descriptive notes, NEW 4” SANITARY SEWER LINE… On the site plan this note is pointed to a water line. Revise the site plan so that it shows: The arrow pointing from Keynote 44, to the 4” private sanitary sewer line. Sheet DP2.0: Item 45. in the descriptive notes, NEW 1 1/2” WATER LINE… On the site plan this note is pointed to a sewer line. Revise the site plan so that it shows: The arrow pointing from Keynote 45, to the 1 1/2” water line. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan. The required revision(s) may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter CC: Project File |
| 03/16/2006 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 03/20/2006 | JCLARK3 | ENV SVCS | REVIEW | Approved | |
| 03/20/2006 | MICHAEL ST. PAUL | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: D05-0034 9484 East 22nd Street World Savings Conditional Approval TRANSMITTAL: March 20, 2006 COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. Please remove the phrase "current zoning RX-1 and SR" from the upper left corner of the development plan on Sheet DP2.0. |
| 03/24/2006 | FRODRIG2 | COT NON-DSD | REAL ESTATE | Completed | no comment |
| 03/28/2006 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 03/30/2006 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | Traffic Engineering recommends APPROVAL of this DP. D. Dale Kelch, PE Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |
| 04/03/2006 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approv-Cond | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D05-0034 World Savings 04/03/06 () Tentative Plat (X) Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: C9-00-03 (*) Time Extension request, before MC on November 1, 2005 NEIGHBORHOOD PLAN: Pantano East Area Plan GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY: March 24, 2006 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached (X) In General Compliance With Planning Comments dated Dec. 23, 05. However, approval is subject to attached (final) comments REVIEWER: msp 791-4505 DATE: March 21, 2006 Department of Urban Planning and Design Comments: D05-0034 World Savings – Development Plan March 21, 2006 Urban Planning and Design staff approves development Plan D05-0034, subject to the following condition being accepted by the Department of Development Service staff for final development plan/mylar approval: The development plan mylar shall include the outlined language below, on sheet DP2.1, as descriptive note # 15: “Mill” finish steel refers to steel that will rust. The exterior of the building is essentially glass with silicone seams. The aluminum frames that support the glass are only visible on the interior of the building. The majority of the major elements to be painted silver, beams and roof edges, are concealed behind the sun screen (metal screen). Only the columns will be visible; the columns are 6-inches in diameter. The building has no other eaves, fascias, or trims. Please refer to the color elevations and the storefront detail sheet. The metal screen shall rust within two months of installation and shall be rusted prior to occupancy. |
| 04/04/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES April 4, 2006 Steve Miller World Savings 1901 Harrison Street Oakland, CA. 94612 Subject: D05-0034 World Savings Development Plan Dear Steve: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per Community Planning, please submit the following documents for sign-off. 1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). AND 1 Double Matte right-reading Océ or Photo Mylar of the Development Plan. The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blueline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from Reproductions, Inc. and billed to you. If you do not already have an account at Reproductions, Inc., please contact them at (520) 622-7747 to arrange for payment. If you are located in Tucson, Reproductions, Inc. will deliver the mylar and two (2) blueline copies to your office. If you are out of town you will need to arrange to pick them up at the CDRC office of Development Services. Should you have any questions, please call me at 791-5608, ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 510-446-4509 |