Permit Number: D05-0031
Parcel: 10408005F

Address:
4755 N ORACLE RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D05-0031
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/31/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
02/03/2006 JOSE ORTIZ ENGINEERING REVIEW Approved As stated in previous review comments a Grading Plan and Grading Permit will be required if the earthwork exceeds 50 CY. Generally, the grading plans may be submitted for review upon approval of the Development/Site plan. D.S. 2-03.5.2

The Drainage Report was reviewed for Development Plan purposes only. A copy of the drainage report will need to be provided with the Grading Plan, and revisions to the drainage report may be required due to proposed grading conditions.

As stated in previous comments a Stormwater Pollution Prevention Plans (SWPPP's) will be required for this project. Submit a set of grading plans and SWPPP's with text; upon completion and submittal of a grading permit application. Subsequent comments may be necessary, depending upon the nature and extent of revisions that occur to the plans.


If you have any questions or need clarification on any of these comments please feel free to contact me at 791-5550 x1191 or Jose.Ortiz@ci.tucsonaz.govs
02/09/2006 JOE LINVILLE LANDSCAPE REVIEW Approved
03/02/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond March 2, 2006

TO: Arden Ranshaw
Arcadis

THRU: Patricia Gehlen, CDRC Project Manager
City of Tucson, Development Services Department

FROM: David McCormick, Tetra Tech, Inc (Contract Reviewer)
Subhash Raval, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Carmax
Development Plan – 3rd Submittal
D05-031

The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Sheet 1. Revise General Note 21 as follows and fill in the blanks as necessary

THIS PROJECT HAS ____ PROPOSED AND ____ EXISTING WASTEWATER FIXTURE UNIT EQUIVALENTS, PER TABLE 13.20.045(E)(1) IN PIMA COUNTY CODE 13.20.045(E).

SHEET 4. The pipe slopes used on the plan are not consistent with the manhole invert elevations and pipe lengths that are shown in tables. The slope and invert elevations between Manhole 1 and Manhole 2 do not work.

Subject to the above required revisions, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Subhash Raval, P.E.
Telephone: (520) 740-6586

Copy: Project
03/03/2006 HEATHER THRALL ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Heather Thrall
Senior Planner

PROJECT: D05-0031
Carmax, 4755 N. Oracle Road
Development Plan

TRANSMITTAL: March 3, 2006

DUE DATE: February 14, 2006

COMMENTS: CONDITIONAL APPROVAL GRANTED, SUBJECT TO THE FOLLOWING REVISEMENTS COMPLETED.

1. ACTION REQUIRED - (Per last review/current review.). Per DS 2-05.2.4.K and ANSI, clarify handicapped accessibility from Turbo Road to the main car sales building. Call out handicapped ramps with truncated domes at both ends of the pedestrian crosswalk in the north parking lot (where sidewalks transition to vehicular use area) using keynote 25.

2. Provide recordation receipt of lot combination covenant.

3. Due to a potential safety concern, please move the crosswalk connection at the south side of the development an additional 110 feet to the east. Then continue north with a striped crosswalk across PAALs. Provide a raised concrete sidewalk where adjacent/parallel to parking spaces. Connect the pedestrian access to the island in parking row 3, then continue across to the island adjacent to the handicapped parking spaces. Be sure to provide handicapped ramps and truncated dome early warning devices where transitioning to a striped crosswalk across PAALs.

4. Clarify type of surface the island is adjacent to the handicapped parking spaces. Clarify if landscaping is provided/required. Keep in mind handicapped/pedestrian access.


5. Should you have any questions on this review, please contact me via email at Heather.Thrall@tucsonaz.gov or at 791-4541x1156.

If you have any questions about this transmittal, please call (520) 791-5608.

C:\planning\cdrc\developmentplan\D05-0031 carmax conditional approval.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan.
03/07/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

March 7, 2006

Arden Ranshaw
Arcadis
3777 East Broadway Blvd., Suite 100
Tucson, AZ 85716

Subject: D05-0031 Car Max Development Plan

Dear Arden:

The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per Community Planning, please submit the following documents for sign-off.

1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal).
AND
1 Double Matte right-reading Océ or Photo Mylar of the Development Plan.

The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blueline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from Reproductions, Inc. and billed to you. If you do not already have an account at Reproductions, Inc., please contact them at (520) 622-7747 to arrange for payment. If you are located in Tucson, Reproductions, Inc. will deliver the mylar and two (2) blueline copies to your office. If you are out of town you will need to arrange to pick them up at the CDRC office of Development Services.

Should you have any questions, please call me at 791-5608.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/


Via fax: 903-2395