Permit Number: D05-0029
Parcel: 13332027B

Address:
45 N BROWN AV

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D05-0029
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/09/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/16/2005 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Revise the landscape and native plant preservation plan to include same limits of grading and to identify natural areas.
The plans submitted do not match.

2) Revise the notes and the legend on the riparian habitat mitigation plan to list the correct mitigation requirements.
Replacement should be 2:1 for shrubs and trees 2"-4" in caliper or 3:1 for tree greater than 4" in caliper.

3) Mitigation is required for all plants, except those that are dead. The inventory does not list any as dead. Revise as necessary.

4) Mitigation is also required for all woody plants and cacti having basal trunk diameters greater than 2 inches, but less than 4 inches that are to be removed as a result of floodplain development. Revise as necessary.

5) Based on the data regarding plant disposition on sheet N-1
the the mitigation requirements require revision. The plans show that 11 Acacia constricta, 7 Acacia greggii, 1 Celtis pallida, 1 Zizyphus obtusifolia, are to be removed. 3:1 mitigation is required for each of these plants.
In addition 1 mitigation plant for each Carnegea gigantea and Ferocactus wislizenii transplanted is required.

6) Ensure that the landscape plan includes the proper number of mitigation plants (see comment 4).

7) All mitigation plantings are to be located adjacent to or within the wash. The cactus removed from the riparian habitat are to be replaced within the habitat zone.

RESUBMITTAL OF ALL PLANS IS REQUIRED
The following include the applicable mitigation standards:
http://dot.ci.tucson.az.us/stormwater/watercourse_preservation/washguidetoM_C.pdf
11/18/2005 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

November 18, 2005

Wocky Redstar
Castro Engineering
3380 W. Ina Road
Tucson, Arizona 85741

Subject: D05-0029 Jacaranda Village Development Plan

Dear Wocky:

Your submittal of November 15, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

2 Copies Revised Development Plan (Landscape, DSD)

2 Copies Revised Landscape and NPPO Plans (Landscape DSD)







Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/


Via fax: 293-2115