Permit Number: D05-0022
Parcel: 116206300

Review Status: Completed

Review Details: REVISION - DEV PLAN

Permit Number - D05-0022
Review Name: REVISION - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2016 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required. Please resubmit the following items:

1) Two rolled sets of the plans
2) A disk that contains all items submitted.
3) Items requested by reveiw staff
4) All items needed to approve these plans.
12/02/2015 KROBLES1 START PLANS SUBMITTED Completed
12/08/2015 KEN BROUILLETTE FIRE REVIEW Approved
12/16/2015 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Completed
12/17/2015 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved Good afternoon, attached is the facilities map associated with the development plan for Menlo Park – Mercado: Commercial Block c, Lots 25 & 38 that was reviewed by the area designer, Josh Necas. If you have any questions or concerns, you can reach Josh Necas at 917-8759.

Thank you

Michael Norris

Tucson Electric Power

Scheduling Coordinator

520-918-8255

mnorris@tep.com
12/18/2015 JOE LINVILLE LANDSCAPE REVIEW Approved
12/18/2015 JOE LINVILLE NPPO REVIEW Passed
12/21/2015 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
12/23/2015 BVIESTE1 ENV SVCS REVIEW Reqs Change The revised Development Plan has been reviewed on behalf of the Environmental Services Dept. and the following will need to be addressed on the resubmittal:

1. Revise the Solid Waste Collection note on the coversheet to include the waste stream calculation per TSM Section 8-01.8.0 based upon the revised uses and square footages.

2. Demonstrate that the 35 ft. long service vehicle can enter and exit the 35 ft. loading space using the turning templates in TSM Section 8, Figure 7.

3. Add a general note that states the building owner’s facility personnel shall watch for the arrival of the service vehicle and shall roll the containers out clearly into the loading space in front of the vehicle when the vehicle arrives and shall roll the containers back into the building after servicing so that the service vehicle operator does not exit the truck.

If there are any questions, I can be reached at kperry@perryengineering.net
12/23/2015 MICHAEL ST. PAUL HC SITE REVIEW Approved Changed from pass to approval per David Rivera
12/30/2015 ELIZABETH LEIBOLD ENGINEERING REVIEW Reqs Change SUBJECT: Rio Nuevo Mercado Block C REVISION Submittal Engineering Review
LOCATION: T14S R13E Section 14
REVIEWER: Elizabeth Leibold, P.E., CPM, CFM
ACTIVITY NUMBER: D05-0022-R1

SUMMARY: The Development Package including the revised Development Plan was reviewed by Engineering. Engineering has reviewed the received items and does not recommend approval of the Development Plan at this time until the following comments are addressed.

COMMENTS:
1) Admin Man Sec.2-07.5.6.A: Clarify in response letter and provide copy of any updated CC&R's regarding the new areas and associated maintenance areas or common areas that will be the responsibility by condominium owners and/or which areas will be the responsibility of the owners of the commercial units.
2) Admin Man Sec.2-07.6.1.E: Address the following easement comments:
a. Submit copies of easement abandonment documentation.
b. Submit updated title report.
c. Assure planviews reflect the current status of easements.
d. Provide sequence number information once data.
e. Add note to plan that conditions of T05BU01511 shall apply to future construction permits.
f. Label any remaining easements with dimensions and type of easement.
3) Admin Man Sec.2-07.5.4.H: In response letter or on planview, explain whether there are changes to design for the loading / commercial / refuse collection access.

Submit revised plan sheets and/or documentation and comprehensive response letter. If you have any questions on the comments, please call me at 837-4934.

Elizabeth Leibold, P.E., CPM, CFM
Civil Engineer
Engineering Division
Planning & Development Services Dept
City of Tucson
12/31/2015 MICHAEL ST. PAUL ZONING REVIEW Approv-Cond Due to the building crossing property lines, the revised DP has been conditionally approved. A Pima County Accessor's Property Tax Parcel Combo must be completed prior to sign off by the CDRC Project Manager.

Final Status

Task End Date Reviewer's Name Type of Review Description
02/26/2016 KROBLES1 OUT TO CUSTOMER Completed