Permit Number: D05-0022
Parcel: 116206300

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D05-0022
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/04/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
05/09/2006 ELIZABETH EBERBACH ENGINEERING REVIEW Approv-Cond DATE: May 9, 2006
TO: Patricia Gehlen; CDRC Coordinator
SUBJECT: Rio Nuevo Mercado Block C Re-submittal Engineering Review
LOCATION: T14S R13E Section 14
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: D05-0022

SUMMARY: The revised Development Plan, a copy of the approved Final Plat, and the response letter were reviewed by Engineering. Engineering has reviewed the received items and recommends conditional approval of the Development Plan for Block "C".

DEVELOPMENT PLAN CONDITIONS OF APPROVAL:
1) City of Tucson Development Standards (DS) Section No.2-05.2.4.G: Provide copies of correspondence from TDOT authorizing less than 20 feet of access area at the north and south ends of the basement parking area.
2) DS Sec.2-05.2.4.H.2: Indicate proposed drainage solutions, such as origin, direction, and destination of flow and method of collecting and containing flow from the roof; a roof drainage plan shall be provided at building plan review stage that matches the approved drainage report. This will include providing roof drainage details that conform to the direction of roof drainage per the drainage report and that indicates how and location of where the stormwater will be directed to offsite, including down spouts and scupper locations.
3) DS Sec.11-01.12.5: Per condition of permit T05BU01511, the soils engineer shall provide professional inspection, including observation during grading excavation, and testing for required compaction. The soils engineer shall provide sufficient observation during the preparation of the natural ground and placement and compaction of the fill to verify that such work is being performed in accordance with the conditions of the approved plan and the appropriate requirements of the grading development standards. Any revised recommendations relating to conditions differing from the approved soils engineering and engineering geology reports shall be submitted to the DSD and the project's civil engineer. Submit copies of Geotechnical / Soils Reports to DSD for soil conditions and observations during excavation at building permit review stage and before issuance of building permit.

Submit TDOT correspondence to the CDRC office for engineering review. If you have any questions on the comments, please call me at 791-5550 extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
05/10/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond May 9, 2006

TO: Gallagher Witmer
Gallagher Witmer, Architect LLC

THRU: Debbey Marchbanks, Subdivision Coordinator
Pima County Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Commercial Lot/Block “C”
Development Plan/Tentative Plat – 3rd Submittal
D05-022



The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


SHEET 1. As the private sewers are proposed, please replace General Note 4 with

ON-SITE SANITARY SEWERS WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT AT THE TIME OF SUBMITTAL OF PLUMBING OR BUILDING PLANS.

Subject to the above required revisions, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.

If you have any questions regarding the above mentioned comments, please contact me.

Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
05/11/2006 ELIZABETH EBERBACH ENGINEERING review Approved DATE: May 11, 2006
TO: Patricia Gehlen; CDRC Coordinator
SUBJECT: Rio Nuevo Mercado Block C Re-submittal Engineering Review
LOCATION: T14S R13E Section 14
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: D05-0022

SUMMARY: TDOT correspondence received 11MAY06 and is acceptable for conditional approval item 1 of Development Plan for Block "C".

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services
05/11/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D05-0022 COMMERICAL LOT/BLOCK “C”/REVISED DEVELOPMENT PLAN
DATE: May 10, 2006



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

NOTE:

1: Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved
Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima
County Addressing prior to assignment of addresses.

2: All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.













jg
05/22/2006 CRAIG GROSS ZONING REVIEW Approv-Cond No blank spaces can occur on the approved development plan. Unless you want to wait for final DP approval when you get the sewer easements recorded you can label them as "recorded by separate instrument" and remove the Dkt. and Pg. blanks on the final mylars.
06/03/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

June 3, 2006

Gallagher Witmer
Gallagher Witmer, Architect, LLC.
320 East Speedway Blvd.
Tucson, AZ 85705

Subject: D05-0022 Commercial Lot/Block "C" - Menlo Park Mercado Development Plan

Dear Gal:

The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per Community Planning, please submit the following documents for sign-off.

1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal).
AND
1 Double Matte right-reading Océ or Photo Mylar of the Development Plan.

The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blueline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from Reproductions, Inc. and billed to you. If you do not already have an account at Reproductions, Inc., please contact them at (520) 622-7747 to arrange for payment. If you are located in Tucson, Reproductions, Inc. will deliver the mylar and two (2) blueline copies to your office. If you are out of town you will need to arrange to pick them up at the CDRC office of Development Services.

Should you have any questions, please call me at 791-5608.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/


Via fax: 882-4022