Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: D05-0020
Parcel: 107121810

Address:
2851 N BALBOA AV

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D05-0020
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/18/2006 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/08/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approved August 7, 2006


TO: Eduardo H. Gonzalez.
Rick Engineering, Company.

THRU: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

FROM: Chandubhai C. Patel, P.E.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Development Plan For Beacon Group Expansion
Lots 1,4,5,8 & 9 of Block 25
D05-020, 3rd Submittal


The drawings for the Development Plan of the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD).


The Pima County Department of Environmental Quality and the Wastewater Management Department hereby approve the above referenced submittal as received by us on July 18, 2006.

Please note the following: Approval of the above referenced submittal does not authorize
the construction of public or private sewer lines or water distribution lines. Prior to the
construction of such features, a Construction Authorization (Approval To Construct) may
need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the
Pima County Department of Environmental Quality prior to constructing, operating or engaging
in an activity which may cause or contribute to air pollution.


If you have any question regarding the above comments , please do not hesitate to contact me.

Sincerely,



Chandubhai C. Patel, P.E.
Phone: 520-740-6563


Copy: Project
09/01/2006 KAROL ARAGONEZ ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Karol Aragonez
Planner

PROJECT: D05-0020
Beacon Group Expansion
Development Plan Resubmittal

TRANSMITTAL DATE: July 18, 2006

DUE DATE: August 15, 2006

COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Please provide the more specific use as described in the Zoning Administrator (ZA) letter and LUC as "Educational Use: Elementary and Secondary Schools". This affects general note 3 and Parking calculations note 1 & 4.

2. The development plan (DP) cannot be approved until the recordation information is provided for electric easement vacation. Please contact David Rivera, Principal Planner 791-5608 for direction on potential DP approval.

3. Please add handicapped ramps with truncated domes in the following places:
A) On current lot 4 - at both ends of the concrete island connected by cross-walks in the east parking lot area.
B) On current lot 1 - at the end of the sidewalk transitioning to the cross-walk to cross the PAAL.

4. Please correct off-street loading calculations for required spaces. Civic Use Group requires using LUC 3.4.5.4, Table 4, which requires GFA between 25,001 through 75,000 to provide two (2) off-street loading spaces, twelve (12) feet by thirty-five (35) feet.
LUC 3.4.5, LUC 3.4.5.4 Table 4

5. Please revise the bicycle parking calculations. Required bicycle parking for educational uses grade K-8, as determined by the ZA letter is one (1) space per ten (10) students and employees - all class 2. Also be aware that that development standard 2-09 has been revised. Per DS 2-09.4.1 Class 2 bicycle parking facilities will be located no more than fifty (50) feet from the main building entrance(s) and will be along the front side of the building as well as along other sides of the building that has an entrance. Bicycle access through the development will be separate from the pedestrian ways. Vehicular access may be used as bicycle access. Bicycle access to a parking facility may cross a pedestrian way at a right angle (DS2-09.3.2). Multiple rack bicycle parking require a minimum thirty (30 inches between outer spaces of posts or racks (DS 2-09.5.1.A). The applicant should revise plan as required. The revised standards can be found at the DSD web site: http://www.tucsonaz.gov/dsd/Codes___Ordinances/DevStd209.pdf
LUC 3.3.4 Educational Use Grades K-8

6. Please note, depending upon the information provided on the resubmittal, further review comments may be forthcoming.

If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550.

KAA C:\planning\cdrc\developmentplan\D05-0020dpr.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and additional requested documents.
09/06/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 6, 2006

Bruce M. Paton
Rick Engineering Company
1745 East River Road, Suite 101l
Tucson, Arizona 85718

Subject: D05-0020 Beacon Group Expansion Development Plan

Dear Bruce:

Your submittal of July 18, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

2 Copies Revised Development and Landscape Plans (Zoning, DSD)









Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/
Via fax: 322-6956