Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: D05-0016
Parcel: 13405116F

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D05-0016
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/07/2006 DAVID RIVERA ZONING REVIEW Approv-Cond CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: D05-0016
Hazen Office Building
Development Plan

TRANSMITTAL DATE: January 7, 2006

DUE DATE: December 21, 2005

COMMENTS:

1. The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements.

2. The annotation for the new sewer easement must be revised to state "New Sewer Easement" instead of New PAAL Access Easement. If the new sewer easement recordation information must be listed on the development plan if the easement is to be recorded by separate instrument. The abandonment of the existing sewer easement must also occur prior to final approval of the development plan by the CDRC manager. Please contact Patricia Gehlen for additional information on this issue.

3. The following drafting items must be cleaned up.

a. Dimension the back of the back up spur between the curb and the property line. The required setback from the property line is three feet.

b. The truncated domes have been depicted incorrectly on the access ramp details. The domes are to be placed on the portion of the ramp that is adjacent to the access aisle.

c. Access ramps are required at the ends of the crosswalk, which is next to the loading zone. All access ramps are to be provided with truncated domes. Add a note stating that all access ramps will be designed and constructed with the required truncated domes.

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

C:\planning\cdrc\developmentplan\D050016dpca.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, and additional requested documents.
01/18/2006 FRODRIG2 PIMA COUNTY WASTEWATER Approved January 17, 2006

To: Bruce Wilson, Landmark Engineering

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael Harrington (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Hazen Offices Buildings
Development Plan – 4th Submittal
D05-016

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



The Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan as submitted.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
01/19/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

January 19, 2006

E. Bruce Wilson, P.E., R.L.S.
Landmark Engineering
3845 North Business Center Drive, Suite 107
Tucson, AZ 85705

Subject: D05-0016 Hazen Office Building Development Plan

Dear Bruce:

The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per Community Planning, please submit the following documents for sign-off.

1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal).
AND
1 Double Matte right-reading Océ or Photo Mylar of the Development Plan.

The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blueline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from Reproductions, Inc. and billed to you. If you do not already have an account at Reproductions, Inc., please contact them at (520) 622-7747 to arrange for payment. If you are located in Tucson, Reproductions, Inc. will deliver the mylar and two (2) blueline copies to your office. If you are out of town you will need to arrange to pick them up at the CDRC office of Development Services.

Should you have any questions, please call me at 791-5608.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/


Via fax: 628-1392
12/07/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
12/19/2005 PMCLAUG1 LANDSCAPE REVIEW Approv-Cond The landscape is conditionaly approved subject to the following revision:
The landscape plan indicates that the entire wall along the south property line is 6 feet in height, but the development plan shows that only 25 linear feet of the wall to the south of the loading zone is 6-feet in height, with the remainder of the wall being 5 feet high. Revise to be consistent. If only a portion of the wall is to be 6 feet in height for screening of the loading zone, indicate on the drawing the location where the height change occurs.
12/19/2005 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering recommends APPROVAL of this DP (again).

D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov