Permit Number: D05-0014
Parcel: 12907004A

Address:
1820 E 22ND ST

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D05-0014
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/22/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
09/23/2005 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Revise the the granite placement detail to specify a 2" layer per DS 2-06.5.2.C.

2) A vehicular use area must be provided wheel stop curbing designed to prevent parked vehicles from damaging adjacent walls. Wheel stop curbing is to be located two and one-half (2½) feet from the front of the parking spaces behind the loading zone screen wall. DS 3-05.2.3.C.1&2
09/23/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D05-0014 OASIS BOTTLED WATER / REVISED DEVELOPMENT PLAN
DATE: September 23, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1: Per recorded legal description for Parcel 129-07-004A, the south 183 feet of
the parking for this project is on Lot 3, Block 2 of Neff Addition, recorded in
Bk. 3, Pg. 91. You will need to add this description (plus) “a portion of the
NE4, NE4” to Sheet 1.
09/29/2005 JCLARK3 ENV SVCS REVIEW Denied * Detail of refuse enclosure is the same as the origional submittal. Ten feet clear area is required between bollards of rear and side walls.
* Enclosure angle as shown blocks the PAAL when being serviced. Recommend tha the angle be 30 degrees to the PAAL approach.
* No provisions shown for recyling.
10/07/2005 FRODRIG2 COT NON-DSD REAL ESTATE Approved No comment, spandrel dedication has been completed, Dkt 12625, at Pg 1580.
10/10/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D05-0014 Oasis Bottled Water 10/10/05

( ) Tentative Plat
(ü) Development Plan
(ü) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other

CROSS REFERENCE: C9-04-20

NEIGHBORHOOD PLAN: Greater South Park Area Plan

GATEWAY/SCENIC ROUTE: N/A

COMMENTS DUE BY: October 6, 2005

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
(ü) See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
(ü) Resubmittal Required:
( ) Tentative Plat
(ü) Development Plan
(ü) Landscape Plan
( ) Other

REVIEWER: K.Aragonez 791-4505 DATE: 10/6/05

1. A copy of the Landscape plan is requested to verify that condition 8 of rezoning case C9-04-20 has been met.

2. For this new configuration to not be considered a change in concept the property lines must be expanded to include the property to the east. (per pervious discussion with Glenn Moyer and Aline Torres) If the plan does not incorporate the additional lot, loading and refuse collection does not work. If you need additional information concerning this please contact Aline Torres at Development Services at 791-4541.

3. Please demonstrate that the off-street loading spaces will work. There should be sufficient maneuverable space to allow the trucks to enter and exit the space.
10/11/2005 DAN CASTRO ZONING REVIEW Denied COMMENTS

1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is April 26, 2006.

2. As a result of the revised parking layout, a vehicular cross parking and access agreement is required for this site. Provide a copy of the agreement for review. The agreement shall then be recorded and a copy of the recorded agreement shall be submitted to the Zoning Review section for our records. A note shall also be added to the drawing listing the cross access and parking agreement along with the docket and page reference. (D.S. 2-05.2.4.A)

3. Per D.S. 2-08.4.1.A, at least one (1) sidewalk shall be provided to each street the project has frontage. Provide a sidewalk from the building to the sidewalk located within 22nd Street right-of-way. (D.S. 2-05.2.4.K)

4. Is access proposed from Martin Street? If so, demonstrate maneuverability for a loading zone from Martin Street. In addition, indicate if Martin Street is improved/paved as a note on the drawing.


5. Provide, as a note on the drawing, to whom the loading zone located on the adjacent property will serve. (D.S. 2-05.2.4.O)

6. The square footage of the building noted on the drawing and listed under the GFA calculation does not match the GFA listed under the vehicle parking calculation. Revise for consistency. (D.S. 2-05.2.4.P) (LUC 3.3.4)

7. The bicycle parking facility shown on the drawing and details is a Class II facility. The class type on the drawing and calculation is incorrectly referred to as Class I. Revise as required. (D.S. 2-05.2.4.Q)

8. Per D.S. 2-09.4.1, Class II spaces shall be located conveniently to the main entrance of the building. The location shown on the drawing does not meet this standard. Relocate as required.

9. Provide a separate response letter, which addresses how all rezoning conditions have been met. (D.S. 2-05.2.4.U)

10. All on-site sidewalks shall be physically separated from the vehicular use area. The sidewalk located between the building and the PAAL does not comply with D.S. 2-08.4.1. Revise as required.

11. All requested changes must be made to the development and landscape plans.

If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180.
10/11/2005 LOREN MAKUS ENGINEERING REVIEW Denied DATE: October 11, 2005

To: Patricia Gehlen
CDRC/Zoning Manager
FROM: Loren Makus, EIT
Engineering Division


SUBJECT: Oasis Bottled Water Expansion
Development Plan D05-0014 (Second Review)
T14S, R14E, Section 19

RESUBMITTAL REQUIRED: Revised Development Plan

The Engineering Division has reviewed the Development Plan and Drainage Report for Silverbell Pavilion and does not recommend approval at this time.

Development Plan Comments:

1. As previously commented, show sufficient existing and proposed grades and drainage patterns to demonstrate that water harvesting will be achieved as described in the drainage statement and as required by LUC 3.7.4.5.B. Show how that runoff from the roof and parking areas will be directed through the landscape areas to the maximum extent practicable. In the response letter provide a clear discussion of the changes to the development plan as well as a clear explanation for the limitations imposed by site geometry.
2. As previously commented, provide recordation information for all adjacent rights-of-way.
3. Show that the loading zone and solid waste container can be accessed by the appropriate design vehicle. Show turning radii for access from the street to the on-site location and to the street again.

A complete grading permit submittal and Stormwater Pollution Prevention Plan will be required for this project.
If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov.

Loren Makus, EIT
Senior Engineering Associate
10/14/2005 DALE KELCH COT NON-DSD TRAFFIC Denied Traffic Engineering REJECTS this DP:

1. List the name, ROW width, recordation data, type and dimensioned with of paving, curbs, curb cuts and sidewalks. (DS 2-05.2.2.D). There is still no recordation data for 22nd St. or 23rd St.

2. Based on aerial photography and information obtained from Pima County Mapguide, there is no Martin Avenue. There does not appear to be any ROW of any name in this location. Please verify.

D. Dale Kelch, PE
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
10/20/2005 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond October 19, 2005

To: Ray Cossette, Urban Engineering

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael Harrington (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Oasis Bottled Water 1820 E 22nd St. Lot 3, Blk. 2
Development Plan - 2nd Submittal
D05-0014

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



Tim Rowe has waived item #1, of Dickie Fernandez, review letter dated May 10, 2005,

Sheet 1: Revise the table reference in General Note #30 to read 13.20.045(E)(1)

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
10/26/2005 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

October 26, 2005

Ray Cossette
Urban Engineering, Inc.
877 S. Alvernon Way
Tucson, AZ 85711

Subject: D05-0014 Oasis Bottled Water Development Plan

Dear Ray:

Your submittal of September 22, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

8 Copies Revised Development Plan (addressing, environmental services, urban planning and design, engineering, zoning, landscaping, traffic, DSD)

5 Copies Revised Landscape Plan (urban planning and design, zoning, engineering, landscaping, DSD)




Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 318-3808