Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D05-0014
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/16/2005 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed | |
| 11/18/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 11/22/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: D05-0014 OASIS BOTTLED WATER/REVISED DEVELOPMENT PLAN DATE: 11/21/05 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. NOTE: 1: Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2: All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. |
| 11/28/2005 | JCLARK3 | ENV SVCS | REVIEW | Approved | |
| 11/30/2005 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | Traffic Engineering recommends APPROVAL of this DP. D. Dale Kelch, PE Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |
| 12/01/2005 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | DATE: December 1, 2005 To: Patricia Gehlen CDRC/Zoning Manager FROM: Loren Makus, EIT Engineering Division SUBJECT: Oasis Bottled Water Expansion Development Plan D05-0014 (Third Review) T14S, R14E, Section 19 RESUBMITTAL REQUIRED: None The Engineering Division has reviewed the Development Plan for Oasis Bottled Water and recommends approval. A complete grading permit submittal and Stormwater Pollution Prevention Plan will be required for this project. If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov. Loren Makus, EIT Senior Engineering Associate |
| 12/02/2005 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS 1. General comment: Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is April 26, 2006. 2. Per David Rivera, Principal Planner in the Zoning Review Section, the lot combination covenant does not grant cross access rights. A separate recorded cross access and parking agreement is required for this site. The cross access agreement is required for the subject property and the adjacent property (parcel number 129-08-018A). The response to the previous comment indicates that a copy of the Lot Combination Covenant was submitted to CDRC on September 22, 2005. A copy of this covenant was not found in the CDRC file. Please forward a copy of the Covenant to the CDRC office and a copy with the resubmittal of this plan to the Zoning Review Section. Previous comment: As a result of the revised parking layout, a vehicular cross parking and access agreement is required for this site. Provide a copy of the agreement for review. The agreement shall then be recorded and a copy of the recorded agreement shall be submitted to the Zoning Review section for our records. A note shall also be added to the drawing listing the cross access and parking agreement along with the docket and page reference. (D.S. 2-05.2.4.A) 3. Response to the previous comment indicates that access from Martin Street will be provided and paving information has been added to the plans. The actual plans submitted do not show the paving information but do show a curb and fence along the property line abutting Martin Street. Please clarify whether or not Martin will be used for access. Previous comment: Is access proposed from Martin Street? If so, demonstrate maneuverability for a loading zone from Martin Street. In addition, indicate if Martin Street is improved/paved as a note on the drawing. 4. The proposed building area noted under development calculation three (3) on the cover sheet is listed incorrectly as 114,592 S.F. Revise to 14,592 S.F. (D.S. 2-05.2.4.P) 5. Under development calculation three (3) on the cover sheet, revise the number of bicycle parking spaces required to two (2) Class II and list the number and class type provided as two (2) Class II provided. (D.S. 2-05.2.4.Q) 6. Detail one (1) on sheet 2 of 3 shows a curb blocking the access aisle, which is also being used as the accessible pedestrian path to Neff Street. Remove the curb from the detail and the drawing on sheet 3 of 3. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. |
| 12/05/2005 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D05-0014 Oasis Bottled Water 11/29/05 ( ) Tentative Plat () Development Plan () Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other CROSS REFERENCE: C9-04-20 NEIGHBORHOOD PLAN: Greater South Park Area Plan GATEWAY/SCENIC ROUTE: N/A COMMENTS DUE BY: December 1, 2005 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies With Plan Policies ( ) See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: 10/10/05 ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: K.Aragonez 791-4505 DATE: 11/29/05 |
| 12/14/2005 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES December 14, 2005 Ray Cossette Urban Engineering, Inc. 877 S. Alvernon Way Tucson, AZ 85711 Subject: D05-0014 Oasis Bottled Water Development Plan Dear Ray: Your submittal of November 17, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 2 Copies Revised Development Plan (zoning, DSD) 2 Copies Revised Landscape Plan (zoning, DSD) Should you have any questions, please call me at 791-5608, ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 318-3808 |