Permit Review Detail
Review Status: Completed
Review Details: REVISION - DEV PLAN
Permit Number - D05-0011
Review Name: REVISION - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/29/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 04/05/2007 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 04/17/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | Revise the plans to remove the proposed plantings along the southern boundary from the vehicle overhang. Locate plants to eliminate interference with parking requirements. Provide details for planting areas within and adjacent to riprap areas along the southern boundary. Provide the minimum unpaved planting area per LUC 3.7.2.3.A.1.c The proposed riprap will have colors which are predominant within the surrounding landscape, such as desert and earth tones per LUC 2.8.2.10.A. Provide specifications. |
| 04/18/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D05-0011 Rita Houghton Retail Center Revision Development Plan TRANSMITTAL DATE: April 18, 2007 DUE DATE: April 26, 2007 COMMENTS: 1. The Zoning Review Section approves the development plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960. KAA S:\zoning review\karol\planning\cdrc\developmentplan\D05-0011dp.doc |
| 05/03/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES May 3, 2007 Thomas Sayler-Brown SBBL Architects 1001 North Alvernon Way Tucson, AZ 85711 Subject: D05-0011 Rita Houghton Retail Center Development Plan Dear Thomas: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once any necessary corrections are made, please submit the following documents for sign-off. 1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). AND 1 Double Matte right-reading Océ or Photo Mylar of the Development Plan. The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blueline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from Reproductions, Inc. and billed to you. If you do not already have an account at Reproductions, Inc., please contact them at (520) 622-7747 to arrange for payment. If you are located in Tucson, Reproductions, Inc. will deliver the mylar and two (2) blueline copies to your office. If you are out of town you will need to arrange to pick them up at the CDRC office of Development Services. TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html. Should you have any questions, please call me at 791-5608, ext. 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 620-0535 |