Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - CDRC - DEV PLAN
Permit Number - D05-0003
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/04/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 04/14/2005 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | |
| 04/14/2005 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | REVIEWER: K. Aragonez DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D05-0003 Civano Holistic Institute 04/14/05 ( ) Tentative Plat (ü) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment (ü) Other (parking inventory) CROSS REFERENCE: C9-91-14, PAD-6 NEIGHBORHOOD PLAN: South Pantano GATEWAY/SCENIC ROUTE: N/A COMMENTS DUE BY: April 18, 2005 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies With Plan Policies ( ) See Additional Comments Attached (ü) No Additional Comments - Complies With Planning Comments Submitted on: 2/17/05 ( ) Resubmittal Required: ( ) Tentative Plat ( ) Development Plan ( ) Landscape Plan ( ) Other REVIEWER: K. Aragonez 791-4505 DATE: 4/13/2005 |
| 04/20/2005 | CRAIG GROSS | ZONING-DECISION LETTER | REVIEW | Completed | |
| 04/20/2005 | DAN CASTRO | ZONING | REVIEW | Approv-Cond | The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 1. Revise the bicycle parking calculation to state the correct number of bicycle parking spaces required. Per LUC Sec. 3.3.3.5, if the calculated number of required bicycle parking spaces is less than two (2) 9 x 8% = .72, the minimum number of required spaces for this project is two (2). The calculation shall be listed as follows: 2 bicycle parking spaces x 40% = 2.8 , which must be rounded up to a total of three (3) spaces required. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180. |