Review Details: REVISION - DEV PLAN
Permit Number - D05-0003
Review Name: REVISION - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/20/2006 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 11/02/2006 | KAROL ARAGONEZ | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D05-0003 Civano Holistic Institute Development Plan TRANSMITTAL DATE: November 2, 2006 DUE DATE: November 20, 2006 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is November 19, 2007. 2. Please revise zoning note. Remove reference to PAD-6A and SP-6a and replace with PAD-12, Civano Master PAD, Neighborhood 1PAD District. 3. Please provide an updated parking inventory to verify parking for commercial uses. 4. Please revise the parking calculation for the total number of required spaces to five (5). Per LUC 3.3.3.8 when the final result of the calculation of required motor vehicle parking results in a fractional number, a fraction less than one-half (1/2) is adjusted to the next lower whole number. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197. KAA S:\zoning review\karol\planning\cdrc\developmentplan\D05-0003dp.doc RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan and additional requested documents. |
| 11/13/2006 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Denied | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D05-0003 Civano Holistic Institute 11/08/06 ( ) Tentative Plat (ü) Development Plan ( ) Landscape Plan ( ) Revised Plan/Plat ( ) Board of Adjustment ( ) Other (parking inventory) CROSS REFERENCE: C9-91-14, PAD-6 NEIGHBORHOOD PLAN: South Pantano GATEWAY/SCENIC ROUTE: N/A COMMENTS DUE BY: November 20, 2006 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: ( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment ( ) Proposal Complies with Annexation or Rezoning Conditions ( ) RCP Proposal Complies With Plan Policies (ü) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: (ü) Resubmittal Required: ( ) Tentative Plat (ü) Development Plan ( ) Landscape Plan (ü) Updated Parking Inventory REVIEWER: JBeall 791-4505 DATE: 11/06/2006 The applicant has added personal service use and reduced the office use square footage. See the following comments. 1) Please provide an updated parking inventory to verify parking for commercial uses. 2) Please revise the parking calculations for the total number of required spaces to five (5). Per LUC a fraction less than one-half is adjusted to the next lower whole number. 3) Please indicate the number of bike spaces provided. The General Notes section under Bike Parking appears to leave this blank. 4) Please remove reference to PAD-6A and SP-6a and replace with PAD-12, Civano Master PAD, Neighborhood 1 PAD District. |
| 12/01/2006 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES December 1, 2006 Ingrid Anderson Civano Holistic Institute 10522 East Eleanor Maldonado Street Tucson, Arizona 85747 Subject: D05-0003 Civano Holistic Institute Revised Development Plan Dear Ingrid: Your submittal of October 23, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 3 Copies Revised Development Plan (Zoning, DUPD, DSD) 3 Copies Revised Parking Inventory (Zoning, DUPD, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: No fax/Sent by mail |