Permit Number: D05-0002
Parcel: 124190800

Address:
1841 E 18TH ST

Review Status: Completed

Review Details: DEVELOPMENT PLAN

Permit Number - D05-0002
Review Name: DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/19/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
01/20/2005 JIM EGAN COT NON-DSD FIRE Approved The Development Plan is approved January 20, 2005.
01/24/2005 JCLARK3 ENV SVCS REVIEW Approved * No known landfill with in 1000 feet of this devevopment.
* Parking lot -No refuse enclosures required.
01/28/2005 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved NO COMMENT
D05-0002
LANDMARK ENGINEERING,INC
18TH STREET PARKING LOT
02/02/2005 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: 18th Street Parking Lot
D05-0002

Tucson Electric Power Company has reviewed and approved the development plan
dated January 12, 2005.


Liza Castillo
Land Management
Tucson Electric Power Company
lcastillo@tep.com
Office: (520) 917-8745
Cell Phone: (520) 904-2668
Fax: (520) 917-8700
02/02/2005 KAY MARKS PIMA COUNTY ADDRESSING Denied 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D05-0002 18TH STREET PARKING LOT / DEVELOPMENT PLAN
DATE: FEBRUARY 2, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval:

1: Delete direction from street names in Location Map.

2: Correct Legal Description to read Lot 1 of Campbell-Tucson, Bk 56, Pg 2. Delete
reference to Cherry/Campbell Redevelopment in Legal Description and Location
Plan.

3: Delete: Resubdivision of a portion of Lot 18 of Cherry/Campbell Redevelopment
M & P 11/27 in Title Block. (S01-002 should only be a reference number).

4: Correct Cherry Campbel Redevelopment Lots 2-3 to Campbell-Tucson, Lot 2,
Bk 58, Pg 2.

5: Add Bk 11, Pg 27 to Cherry Campbell Redevelopment Lot 18.

6: Provide sheet 2 of this project.
02/14/2005 DOUG WILLIAMS ENGINEERING REVIEW Denied SUBJECT: 18th Street Parking Lot - Development Plan review comments
REVIEWER: Douglas Williams
DATE: 14 February 2005
ACTIVITY NUMBER: D05-0002

Resubmittals Required: Revised Development Plan, Landscape Plan, and Hydrology Report.

SUMMARY: Engineering Division has reviewed the Development and Landscape Plans, and Hydrology Report submitted. Approvals are not recommended at this time. Please provide a response letter, a revised Hydrology Report and revised Development and Landscape Plans addressing all comments provided below.

HYDROLOGY REPORT:
1. Please include the name, address, and telephone number of the client for whom the report was prepared, in accordance with the City of Tucson Standards Manual for Drainage Design and Floodplain Management (SMDDFM), Section 2.3.1.1.C (Development Standard - DS 10-02.0).
2. Please correct the inconsistency between the labeling for the existing box culvert (9" x 17" x 199' RCBC) on Figure 5, and the text discussion of a 9' x 7'x 80' RCBC, in the "Lopez Wash" discussion/analysis paragraph on page 4.
3. Use of a contributing area factor other than 1 requires sufficient supporting data (e.g. aerial-photographic analysis and field verification). Provide documentation and verification of such additional analysis in a revised report, or revise applicable calculations and labeling, accordingly (hydrologic data sheets, text discussion and figure 5), (DS 10-02.0, Sec. 4.2).
DEVELOPMENT PLAN:
1. Those areas subject to flooding from flows smaller than 100 cfs shall be identified and labeled with flow arrows (DS 10-02.0, Section 2.3.1.4 C 2).
2. Each significant concentration point along with its peak discharge and contributing drainage area(s), shall be labeled (DS 10-02.0, Section 2.3.1.4 C 4 & DS 2-05.2.4 H 7 - offsite acceptance point).
3. Include a symbol with descriptions for the following items, in the legend (DS 2-05.2.1 J):
a) the symbol for the found 2" BCSM and ¼" IP in the 18th Street right of way;
b) lot/property corner symbols;
c) proposed TC/Gutter grade symbol ( this symbol appears identical to the lot/property corner symbol, and should be revised for differentiation between the two);
d) The line provided for right of way dimensioning.
4. If a registered professional (such as a surveyor, architect, engineer) prepared the plans, provide applicable registration or license number along with the seal and signature of the professional (DS 2-05.2.2 A 2).
5. Revise the third word under drainage note (#7) - "and" to read "any" (DS 2-05.2.2 C 1 a).
6. Identify/label the type of line from which right of way dimensioning is provided - such as survey or monument line, section line, construction centerline, right of way centerline, etc., and identify whether a half- or full right of way is dimensioned. Depict and label type and dimensioned width of paving (DS 2-05.2.3 C).
7. Clarify and revise if necessary, the City Field Book and Page referenced under General Note 13 (DS 2-05.2.3).
8. Depict and label existing conditions on the adjacent properties that may affect this project. Particular consideration should be given to elevations/contours on the upstream property, east of the subject parcel (DS 2-05.2.3 H).
9. Depict and label new 5' sidewalk to be constructed in the public right of way (18th St.), 2' from back of curb (DS 3-01.3.3 A), and provide dimensions from street monument line(s) to curb, sidewalk, and all utility locations - fully labeled (DS 2-05.2.4 D 2).
10. Please ensure all easements are clearly depicted, dimensioned and labeled, with recording information provided on the plan - see additional requirements outlined for these Development Standards (DS 2-05.2.3 B & D, 2-05.2.4 G).
LANDSCAPE PLAN:
1. Provide a note for water harvesting maximization in all landscape areas, in accordance with the City's Land Use Code (LUC), Sec 3.7.4.
2. Submit a revised landscape plan reflecting all Landscape Review Section comments and applicable Development Plan revisions made in response to all review comments provided for this submittal.
GENERAL COMMENTS:
Additional comments may be necessary upon resubmittal, depending upon the nature and extent of revisions that occur to the plans.
*A right of way permit will be required for any work in the public right of way. Contact Tucson Department of Transportation - Permits and Codes Section at 791-5100 for questions/inquiries.
*A grading permit may be required for this development. A completed grading permit application with two sets of grading plans and a copy of the stamped/approved Development Plan may be required to be submitted for review and approval, prior to any other permit approval/issuance.
Resubmittal shall require revised Development and Landscape Plans and a revised Hydrology Report addressing all comments provided.
If you have any questions, I can be reached at 791-5550, extension 1189 or via email at Doug.williams@tucsonaz.gov

Doug Williams
Sr. Engineering Associate
Engineering Division
Development Services Department
02/16/2005 FRODRIG2 COT NON-DSD REAL ESTATE Approved No comment
02/17/2005 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Revise the plans to clarify that an appropriate material will be placed between the property line and the curb along 18th St. per LUC 3.7.2.4.A.4.

2) Revise plans to conform to the canopy tree requirements of LUC 3.7.2.3.A. "Within a vehicular use area, one (1) canopy tree is required for each ten (10) motor vehicle parking spaces or fraction thereof.
a. The canopy trees must be evenly distributed throughout the vehicular use area. Every parking space shall be located within forty (40) feet of the trunk of a canopy tree (as measured from the center of the tree trunk).

3) Relocate screening materials along 18th St. as necessary to comply with LUC 3.7.3.2.C.2. "Hedges and other vegetative screens shall not extend more than three (3) feet into the street landscape border. If, based on the growing characteristics of the type of plant used, the ultimate
width of the vegetative screen will be greater than three (3) feet, the vegetative screen must be sufficiently set back from the landscape border to accommodate the wider growth."
Also, verify that the vegetative coverage exceeds fifty percent. Per DS 2-06.3.7 "The use of vegetation to satisfy the screen requirement is allowed only to provide for alternative treatment and is not in any way meant to imply that the vegetative screen can also be used to meet the landscape (coverage) requirement.

4) The native plant preservation application is not approved. There is one existing Acacia greggii at or near the property line along 18th. Revise the landscape plan to show this existing plant as preserved-in place or provide 2:1 mitigation if it is to be removed. Revise the application as necessary.
02/18/2005 TIM ROWE PIMA COUNTY WASTEWATER Approv-Cond February 16, 2005

TO: E. Bruce Wilson, P.E.
Landmark Engineering, Inc.

THRU: Craig Gross
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: 18th Street Parking Lot
Development Plan – 1st Submittal
D05-0002


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Delete the Wastewater Management Note and add the following

THIS PROJECT WILL NOT GENERATE ANY WASTEWATER AND WILL NOT DISCHARGE ANY WASTEWATER INTO THE PIMA COUNTY PUBLIC SEWER NETWORK

ALL SHEETS. Add the project number, D05-0002, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.
If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
02/18/2005 FRODRIG2 OTHER AGENCIES PIMA ASSN OF GOVTS Approved Transportation Information for
Rezoning, Subdivision, and
Development Requests
Delivered to:
Date Delivered:
Development Services - City of Tucson
2/17/2005
Case Number Project Name
Estimated Daily Traffic
(in average 24-hour vehicle trips)
D05-0002 18th Street Parking Lot 0
Pima Association of Governments
Transportation Planning Division
177 N. Church Ave., Suite 405, Tucson, Arizona
85701-1127
(520) 792-1093 FAX (520) 792-9151
02/18/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved February 16, 2005

TO: E. Bruce Wilson, P.E.
Landmark Engineering, Inc.

THRU: Craig Gross
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: 18th Street Parking Lot
Development Plan – 1st Submittal
D05-0002


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Delete the Wastewater Management Note and add the following

THIS PROJECT WILL NOT GENERATE ANY WASTEWATER AND WILL NOT DISCHARGE ANY WASTEWATER INTO THE PIMA COUNTY PUBLIC SEWER NETWORK

ALL SHEETS. Add the project number, D05-0002, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers.

Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the tentative plat. The required revision(s) may be shown on the Mylars.

Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Department of Environmental Quality.

Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution.
If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
02/22/2005 DALE KELCH COT NON-DSD TRAFFIC Denied Traffic Engineering REJECTS this DP:

1. This is a commercial enterprise and as such it shall require 18' radius curb returns at the access point from 18th street vice a standard driveway apron.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
02/22/2005 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved DATE: February 18, 2005

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks, Parks and Recreation

SUBJECT: D05-0002 18th St. Parking Lot: DP


CC: Craig Gross


Staff has no comments




Glenn Hicks
Parks and Recreation
791-4873 ext. 215
Glenn.Hicks@tucsonaz.gov
02/26/2005 DAVID RIVERA ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: David Rivera
Principal Planner

PROJECT: D05-0002
Cherry/Campbell Redevelopment
Development Plan

TRANSMITTAL: February 26, 2005

DUE DATE: February 16, 2005

COMMENTS:

1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is January 18, 2006.

2. For clarification purposes please indicate in the response comments why this site has been submitted as development plan. I could not find anything that requires a development plan submittal, review, and approval. Also please clarify if the parking lot is an expansion of parking areas for any of the adjacent sites.

How is access provided to the development along the north side of the proposed parking lot? It appears that the development is landlocked unless an ingress/egress easement has been reserved over the proposed parking lot.

3. Submit a copy of the subdivision plat S01-002 referenced in the title block. If this plan is for a re-subdivision of land as approved and recorded by the previous plat Project number S01-002 this plan must be recorded as a lot split or possibly a record of survey. Please clarify. DS 2-05.2.1.G and DS 2-05.2.2.B.8

4. If applicable list any subdivision or rezoning case numbers as reference in the lower left right corner of all plan sheets. DS 2-05.2.1.K

5. Add to general note 4 the development designator "34". DS 2-05.2.2.B.3

6. If applicable indicate the location, width, purpose and recordation information of any existing or proposed easements. DS 2-05.2.3.B and DS 2-05.2.4.G

7. If the parking lot is intended for the use of the adjacent development it is considered an expansion of lot area and the adjacent parcel must be meet full code compliance. Full code compliance includes sidewalks, loading zones, handicapped parking, landscaping along street frontages and within the parking lots. It does not appear that a handicapped parking space has been provided. One handicapped parking space with an eight-foot wide handicapped access aisle is required when providing more than 25 parking spaces. Additional comment may be forthcoming on the full code compliance issue based on the responses. Label the width of the parking stalls. DS 2-05.2.4.P

8. Bicycle parking may be required based on the response to comment 7. Additional comments may be forthcoming. DS 2-05.2.4.Q

9. If there is a rezoning case associated to this site and the proposed development please provide a copy of the rezoning letter and list the conditions of rezoning. DS 2-05.2.4.U

10. If applicable indicate the location of existing or proposed freestanding signs. The location, type, size must be labeled. DS 2-05.2.4.W

11. See the landscape review comments related to requirements for landscape borders, screening and NPPO requirements. DS 2-05.2.4.X

If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

DGR C:\planning\cdrc\developmentplan\D050002dp.doc

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, requested documents.
02/28/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed