Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: D04-0038
Parcel: 12510006A

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D04-0038
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/04/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
03/08/2005 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D04-0038 IN-N-OUT BURGER / REVISED DEVELOPMENT PLAN
DATE: MARCH 7, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

NOTE:

1. Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses.

2. All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.
03/09/2005 JCLARK3 ENV SVCS REVIEW Approved
03/11/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D04-0038 In-N-Out Burger 03/11/05

( ) Tentative Plat
(ü) Development Plan
(ü) Landscape Plan
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other

CROSS REFERENCE: D00-0017, D02-0027, C9-56-01, C9-74-34, C9-88-12

NEIGHBORHOOD PLAN: Alvernon-Broadway Area Plan

GATEWAY/SCENIC ROUTE: Broadway (gateway)

COMMENTS DUE BY: March 18, 2005

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
( ) See Additional Comments Attached
(ü) No Additional Comments - Complies With Planning Comments Submitted on: 12/30/2004
( ) Resubmittal Required:
( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
( ) Other

REVIEWER: K. Aragonez 791-4505 DATE: March 8, 2005
03/14/2005 LOREN MAKUS ENGINEERING REVIEW Approved DATE: March 14, 2005

To: Craig Gross
Planning Administrator
FROM: Loren Makus, EIT
Engineering Division


SUBJECT: IN-N-OUT BURGER at El Con
Development Plan D04-0038 (Second Review)
T14S, R14E, Section 9

RESUBMITTAL REQUIRED: NONE

The Engineering Division has reviewed the Development Plan (DP) for the In-N-Out Burger at El Con and recommends approval at this time.

1. The site will use a compactor for its solid waste storage and collection.
If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov.

Loren Makus, EIT
Senior Engineering Associate
03/15/2005 FRODRIG2 PIMA COUNTY WASTEWATER Approved March 14, 2005

TO: Pattie Davis
MMLA-PSOMAS

THRU: Craig Gross
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: In N Out Burger – El Con Mall
Development Plan – 2nd Submittal
D04-0038


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


This project is hereby approved as submitted.

If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
03/18/2005 JOE LINVILLE LANDSCAPE REVIEW Approv-Cond Based on changes proposed in the 3/22/05 correspondence the landscape section recommends approval based on the following condition(s).

1) Clarify the scale of sheets LS-1 and SP1.1, the scale listed does not correspond with the scale bar.

2) Revise SP 1.1 and SP 1.2 to show the same information along Broadway Boulevard: ROW, sidewalks, curbs notations, etc.
03/21/2005 DAN CASTRO ZONING REVIEW Approved COMMENTS
1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is December 21, 2005.

2. Provide a building permit activity number to place a hold on the Certificate of Occupancy for the building. The reason for the hold is to check that the required scrubbers described in rezoning condition 15 are approved by the Building Official. Please contact the permit desk (791-5550 ext. 1124) to obtain information on the permit activity application.


If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608 ext. 1180.
03/21/2005 DAN CASTRO ZONING REVIEW Approved Previous comments dated 3/21/05 have been addressed.
03/23/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed