Permit Number: D04-0036
Parcel: 136087660

Address:
9510 E 22ND ST

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D04-0036
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/08/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
04/19/2005 JCLARK3 ENV SVCS REVIEW Approved
04/20/2005 LAITH ALSHAMI ENGINEERING REVIEW Approv-Cond Laith Alshami, Engineering and Floodplain Review, 04/20/2005

SUBJECT: Old Spanish Trail Marketplace
D04-0036, T14S, R15E, SECTION 23

RECEIVED: Development Plan, Landscape Plan, and Drainage Report on April 08, 2005

The subject submittal has been reviewed. The Drainage Report and the Development Plan are recommended for a conditional approval. The approval conditions are:

Drainage Report:

· Submit with the Grading Plan a revised Geotechnical Report that specifically addresses slope protection (cut and fill) and the required building setbacks from the proposed detention/retention basins.

Tentative Plat/Development Plan:

· Indicate on the Tentative Plat/Development Plan Mylar and on the Final Plat that all proposed easement dedications or abandonments will be processed as part of the Final Plat. If the easements are proposed to be dedicated or abandoned by a separate instrument, they must processed prior to the approval of the final plat and the recordation information must be shown on the final plat.
04/21/2005 JOE LINVILLE LANDSCAPE REVIEW Approved
04/22/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved DEPARTMENT OF URBAN PLANNING & DESIGN

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D04-0036 Old Spanish Trail Marketplace 04/22/05

() Tentative Plat
(x) Development Plan
(x) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-87-02

NEIGHBORHOOD PLAN: Pantano East Area Plan

GATEWAY/SCENIC ROUTE: Scenic Corridor (Old Spanish Trail)

COMMENTS DUE BY: 04/22/05

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
( ) See Additional Comments Attached
(x) No Additional Comments - Complies With Planning Comments Submitted on: 03/04/05
( ) Resubmittal Required:
() Tentative Plat
( ) Development Plan
( ) Landscape Plan
() Other

REVIEWER: Eric Anderson 791-4505 DATE: 04/18/05
05/06/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
05/06/2005 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Department Plans Coordination Office
FROM: Peter McLaughlin
Senior Planner

FOR: David Rivera
Principal Planner

PROJECT: D04-0036
Old Spanish Trail Market Place
Development Plan

TRANSMITTAL: May 6, 2005

DUE DATE: April 22, 2005

COMMENTS

1. Per the letter from Glenn Moyer, dated March 17, 2005, this project is subject to Scenic Corridor Zone requirements. A Scenic Corridor application is currently under review. Add the SCZ case number (SCZ 04-013) to the lower right hand corner on all sheets of the tentative plat/development plan. Once approved add to the Scenic Corridor notes the case number, the date of approval, any conditions imposed and colors/materials approved.
DS 2-05.2.2.B.10

2. Minimum 4-foot sidewalk widths are required for accessibility. Dimension the width of pedestrian sidewalks clearly in all locations. In particular, it is not clear on the drawing that 4-foot pedestrian walks are provided along the south sides of buildings 9 and 12 in the location of the landscape diamonds and between the trash enclosure and the southeast corner of building 11. Dimension the sidewalk width at its narrowest point between the buildings and the diamonds / dumpster. The distance between the bldg. wall and the diamonds scales to only 3 feet on the drawing while the distance to the dumpster scales to only 2 feet. Revise.
DS 2-08.5.1.A

3. To show that there is a minimum 2-way PAAL width of 24 feet provided, dimension the PAAL along the south side of building 11 at its narrowest point (at the location of the dumpster) which scales to something less than the 30 foot dimension shown immediately to the east of this location.


If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development plan, landscape plan