Permit Number: D04-0015
Parcel: 116193660

Address: Unknown

Review Status: Completed

Review Details: REVISION - DEV PLAN

Permit Number - D04-0015
Review Name: REVISION - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/01/2005 MARILYN KALTHOFF START PLANS SUBMITTED Completed
06/09/2005 JOE LINVILLE LANDSCAPE REVIEW Approved
06/16/2005 ELIZABETH EBERBACH ENGINEERING REVIEW Approv-Cond TO: Trish Gehlen; CDRC Coordinator
SUBJECT: Tucson YWCA Revised Development Plan submittal Engineering Review
LOCATION: 525 N Bonita Av
REVIEWER: Elizabeth Eberbach
ACTIVITY NUMBER: D04-0015

SUMMARY: The revised Development Plan was received by Development Services Department Engineering on June 2, 2005. Development Services Department Engineering has reviewed the received items and met with Charles Corrales on June 20, 2005, and recommends conditional approval of the revised Development Plan.

DEVELOPMENT PLAN CONDITIONS:
1) DS Sec.2-03.2.4.L.2: Provide detail of the proposed revised area to clarify that drainage will continue to drain toward the north west basin. Provide spot elevations and flow arrows in plan view or grades in cross sections to assure that drainage within the loading and dumpster area is directed toward the basin.

Fax or submit the detail. If you have questions, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Division
Development Services Department
06/17/2005 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved URBAN PLANNING AND DESIGN COMMENTS


Regarding


CASE NUMBER: CASE NAME: DATE SENT:

D04-0015 YWCA of Tucson 06/16/05
Civic Assembly

() Tentative Plat
( ) Development Plan
( ) Landscape Plan
() Revised Plan/Plat
() Other:

CROSS REFERENCE: N/A

NEIGHBORHOOD PLAN: PAD – Rio Nuevo Redevelopment Plan
Development Area 2

GATEWAY/SCENIC ROUTE: N/A

COMMENTS DUE BY: 6/15/05


SUBJECT DEVELOPMENT PLAN HAS BEEN REVIEWED BY THE COMPREHENSIVE PLANNING TASKFORCE, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions - No Comment
() Proposal Complies with Annexation Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
(XXXX) No Additional Comments - Complies With Planning Comments Submitted on: 12/28/04
() Resubmittal Required:
() Tentative Plat
() Development Plan
() Landscape Plan
() Other:


REVIEWER: Deborah Estolano DATE: 6/14/05
06/17/2005 PETER MCLAUGHLIN ZONING REVIEW Approved
06/20/2005 CRAIG GROSS ZONING-DECISION LETTER REVIEW Approv-Cond COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

June 21, 2005

Charles Corrales
Corrales Engineering
1008 West Saint Mary's Road
Tucson, AZ 85745

Subject: D04-0015 YWCA of Tucson Development Plan

Dear Irene:

The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per Community Planning, please submit the following documents for sign-off.

1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal).
AND
1 Double Matte right-reading Océ or Photo Mylar of the Development Plan.

The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blueline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from Reproductions, Inc. and billed to you. If you do not already have an account at Reproductions, Inc., please contact them at (520) 622-7747 to arrange for payment. If you are located in Tucson, Reproductions, Inc. will deliver the mylar and two (2) blueline copies to your office. If you are out of town you will need to arrange to pick them up at the CDRC office of Development Services.

Should you have any questions, please call me at 791-5608.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/


Via fax: 622-2554