Permit Number: D04-0005
Parcel: 137313730

Review Status: Completed

Review Details: RESUBMITTAL - DEVELOPMENT PLAN

Permit Number - D04-0005
Review Name: RESUBMITTAL - DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/18/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
08/19/2004 JOE LINVILLE LANDSCAPE REVIEW Approved
08/27/2004 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approv-Cond Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D04-0005 Family Dollar Store – Midvale 08/27/04

() Tentative Plat
(XXXX) Development Plan
(XXXX) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-83-34

NEIGHBORHOOD PLAN: Santa Cruz

GATEWAY/SCENIC ROUTE:

COMMENTS DUE BY: 8/31/04

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
(XXXX) Resubmittal Required:
() Tentative Plat
(XXXX) Development Plan
(XXXX) Landscape Plan
(XXXX) Other – Elevations

REVIEWER: D.Estolano 791-4505 DATE: 8/23/04
Urban Planning and Design
Family Dollar/Midvale, D04-0005

The Santa Cruz Area Plan states that new development within or near existing neighborhoods should be designed and scaled to be compatible with existing neighborhood characteristics. The Design Guidelines Manual states this should be done through four-sided architecture. The elevations show that you will be using a brick façade for the front of the store. Please apply the same feature to the side and rear building façades to achieve four-sided architecture.

The Design Guidelines Manual states that dumpsters shall be screened with masonry walls and landscaping. Additionally, it states that the landscape screen around dumpsters shall consist of material such as tile, stone, or brick and plantings up to six-feet high. It also states that the screen walls should be constructed with graffiti-resistant materials and encourages shared dumpsters. Please provide a detail of what type of screening material will be used, and plantings will be provided next to the screen wall. Also, show these on both the development plan and the landscaping plan.
08/27/2004 MICHAEL ST. PAUL ZONING REVIEW Approv-Cond TO: Plans Coordination Office
Development Services Department






PROJECT: D04-005
Family Dollar @ Midvale Park Rd and Irvington
Development Plan


FROM: Michael St.Paul
Planning Technician


FOR: Patricia Gehlen
Principal Planner
Zoning Review Section

TRANSMITTAL:

DUE DATE:


COMMENTS
CODE SECTION/
DEVELOPMENT
STANDARD

The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements.

1.
The development plan number (D04-005) must be placed on each sheet of the development plan, the landscape plan and the NPPO in the lower right corner next to the title block (DS 2-05.2.2.B.1; DS 2-05.2.2.B.2; DS 2-05.2.2.B.3; LUC Sec 2.5.3.2.B.2).



Should the CDRC approve the development plan, please submit a letter to Glenn Moyer, Principal Planner, Rezoning Section, stating how the conditions for case C9- were addressed in the development plan.

As soon as the Planning Department receives verification that all conditions are met, a rezoning ordinance will be scheduled for Mayor and Council consideration.
08/27/2004 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approv-Cond he consultants have been dealing with us on our comments. Both appear to have been addressed. One by a new elevation and the other by a note.
10/08/2004 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Completed COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

September 7, 2004

Irene Volenick
Planning Resources
270 N. Church Ave
Tucson, AZ 85701

Subject: D04-005 Family Dollar Store - Midvale Development Plan

Dear Irene:

Your submittal of June 28, 2004, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

3 Copies Revised Development Plan (zoning, community planning, DSD)

2 Copies Revised Landscape Plan (community planning, DSD)




Should you have any questions, please call me at 791-5608.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 628-7637