| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/28/2004 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/29/2004 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) The proposed temporary retention basin is required to be designed in conformance with DS 10-01. This would include among other things landscaping, dust control and slopes no steeper than 4:1. Revise the development and landscape plans as necessary. LUC 3.7.4.3 2) Revise the landscape plans to show limits of grading for this phase of development. DS 2-07.2.2.B.4 RESUBMITTAL OF ALL PLANS IS REQUIRED. |
| 06/29/2004 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: D04-0005 FAMILY DOLLAR STORE-MIDVALE/REVISED DEVELOPMENT PLAN DATE: 6/29/04 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. 1. Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2. All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. |
| 06/29/2004 | JIM EGAN | COT NON-DSD | FIRE | Approved | The Development Plan is approved June 29, 2004. |
| 06/29/2004 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: FAMILY DOLLAR STORE D04-0005 Tucson Electric Power Company has reviewed and approved the development plan dated June 4, 2004. Please submit a final set of plans including electrical load, paving, and grading plans, to determine how TEP will serve this commercial development. If easements are required, they will be secured by separate instrument. Liza Castillo Land Management Tucson Electric Power Company lcastillo@tep.com Office: (520) 917-8479 Cell Phone/Pager: (520) 904-2668 Fax: (520) 917-8400 |
| 07/08/2004 | LOREN MAKUS | ENGINEERING | REVIEW | Approv-Cond | DATE: July 8, 2004 To: Craig Gross Planning Administrator FROM: Loren Makus, EIT Engineering Division SUBJECT: Family Dollar Store, Midvale Park Development Plan D04-0005 (Second Review) T15S, R13E, Section 03 RESUBMITTAL REQUIRED: None. The Engineering Section has reviewed the Development Plan (DP) for the Family Dollar Store and conditionally recommends approval. The drainage report is accepted for Development Plan Purposes only. The grading permit submittal must include the following: 1. Clearly indicate the extent of the graded area in square feet. Include any disturbed areas in the future development area and in the right-of-way. If the total area exceeds one acre a stormwater pollution prevention plan, meeting the requirements of the AzPDES Construction General Permit is required. Guidance for preparing a SWPPP is available from ADEQ at www.adeq.state.az.us/function/forms/appswater.html#cgp. 2. Provide the results of percolation tests or otherwise show that all of the retained volume in the basins will be disposed of within 12 hours. 3. Provide complete construction details for all drainage structures. If the development plan must be resubmitted, The engineering division requests an opportunity to review the revised development plan. If you have any questions, I can be reached at 791-5550 x1161 or loren.makus@tucsonaz.gov. Loren Makus, EIT Senior Engineering Associate |
| 07/13/2004 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | Traffic Engineering recommends APPROVAL of this DP. D. Dale Kelch, EIT Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |
| 07/15/2004 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Michael St.Paul FOR: Patricia Gehlen Planning Technician Principal Planner PROJECT: D04-005 Family Dollar Midvale Park Rd / Irving TRANSMITTAL: July 14, 2004 DUE DATE: July 14, 2004 COMMENTS CODE SECTION/ DEVELOPMENT STANDARD 1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is February 19, 2005. 2. 3. The development plan number (D04-005) must be placed on each sheet of the development plan, the landscape plan and the NPPO in the lower right corner next to the title block. DS 2-05.2.2.B.1 DS 2-05.2.2.B.2 DS 2-05.2.2.B.3 LUC Sec 2.5.3.2.B.2 4. Identify the right-of-way width and future right-of-way width of West Irvington Road and dimension those half right-of-ways. Also identify the current and future curb locations along Irvington Road and Midvale Park Road. Note that both Irvington Road and Midvale Park Road are MS&Rs. If the existing ROW and the future ROW are the same identify the ROW as both existing and future ROW. DS 2-05.2.3.C DS 2-05.2.4.F 5. If there are no entrances or exits to and from the building along the north side the pedestrian refuge and sidewalk shall not be required. Please place a note state the above on the site plan. DS 2-05.2.4.K DS 3-05.2.2.B.1 DS 2-08.4.1. DS 2-08.4.1.B & F 6. The number of bicycle parking spaces is based on the number of vehicle parking spaces provided. Please revise the calculation DS 2-05.2.4.Q DS 2-08.5.1.A LUC Sec 3.3.3.5 JUC Sec 3.3.7.8.A 7. Indicate the location and type of postal service. DS 2-05.2.4.V 8. A barrier must be provided adjacent to the PAAL on the southwest perimeter of the property being developed to prevent vehicle access to the undisturbed portion of the property. DS 3-05.2.3.C 9. Revise the side walk section of the accessible parking on the detail as well. The maximum slope is 1:12. DS 2-05.2.4.P ICC/Ansi-A117.1-1998 REVISION & RESUBMITTAL OF THE DEVELOPMENT IS REQUIRED. |
| 07/16/2004 | CRAIG GROSS | PIMA COUNTY | WASTEWATER | Approv-Cond | July 16, 2004 TO: Irene Volenick, Planning Resources THRU: FROM: ____________________________________ representing the Pima County Departments of Wastewater Management and Environmental Quality SUBJECT: Family Dollar Store - Midvale Park Road - Submittal D04-0005 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. SHEET C-0. Include the following four General Notes ON-SITE SANITARY SEWERS WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT AT THE TIME OF SUBMITTAL OF PLUMBING OR BUILDING PLANS. MAINTENANCE AND OPERATION OF THE PRIVATE SANITARY SEWER TO ITS POINT OF CONNECTION TO THE PUBLIC SEWER IS THE RESPONSIBILITY OF THE PROPERTY OWNER. ANY WASTEWATER DISCHARGED INTO THE PUBLIC SANITARY SEWERAGE SYSTEM SHALL MEET THE REQUIREMENTS OF THE INDUSTRIAL WASTE ORGINANCE (PIMA COUNTY ORDINANCE NO. 1991-140, AS AMENDED). A PROJECT CONSTRUCTION PERMIT MUST BE SECURED FROM PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT BEFORE BEGINNING ANY WORK ON THIS PROJECT. SHEET C-3. Show the Pima County plan number on the existing sewer line(s). While the existing manhole numbers and their information is shown, the Pima County plan number must be shown. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan. The required revision(s) may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature. Copy: Project |
| 07/16/2004 | CRAIG GROSS | ZONING-DECISION LETTER | REVIEW | Completed | |
| 07/16/2004 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Denied | Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D04-0005 Family Dollar Store – Midvale 7/16/04 () Tentative Plat (XXXX) Development Plan (XXXX) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: C9-83-34 NEIGHBORHOOD PLAN: Santa Cruz GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: 7/12/04 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: (XXXX) Resubmittal Required: () Tentative Plat (XXXX) Development Plan (XXXX Landscape Plan (XXXX) Other – Architectural Submittals REVIEWER: DCE 791-4505 DATE: 07/08/04 Comprehensive Planning Task Force Family Dollar/Midvale, D04-0005 The Santa Cruz Area Plan states that new development within or near existing neighborhoods should be designed and scaled to be compatible with existing neighborhood characteristics. The Design Guidelines Manual states this should be done through four-sided architecture. Please submit elevations of all four sides of the proposed building. Please design side and rear building façades with attention to architectural character and detail comparable to the front façade. The resubmittal states that these requests have been shown in the architectural submittals. We did not receive a copy of the architectural submittals. Please provide the department of Urban Planning and Design with a copy of the architectural submittal. The Design Guidelines Manual states that dumpsters shall be screened with masonry walls and landscaping. Additionally, it states that the landscape screen around dumpsters shall consist of material such as tile, stone, or brick and plantings up to six-feet high. It also states that the screen walls should be constructed with graffiti-resistant materials and encourages shared dumpsters. Your resubmittal states that the dumpster enclosure shall be built to C.O.T. D.S. 2-05.2.4.T and D.S. 6-01. Please indicate what type of screening material will be used, and what type of plantings will be provided next to the screen wall. Provide a detail of lighting and a note to the General Notes on the Development Plan that reads “All lighting shall be directed down and away from adjacent residential properties.” The resubmittal states that these requests have been shown in the architectural submittals. We did not receive a copy of the architectural submittals. Please provide the department of Urban Planning and Design with a copy of the architectural submittal. |