Review Status: Completed
Review Details: RESUBMITTAL - DEVELOPMENT PLAN
Permit Number - D03-0037
Review Name: RESUBMITTAL - DEVELOPMENT PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/30/2004 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 04/30/2004 | DAN CASTRO | ZONING | REVIEW | Approv-Cond | The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 1. Label and dimension existing and future ½ right-of-way for Stone Avenue on both phase I and phase II plans. D.S. 2-05.2.4.F If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608. |
| 04/30/2004 | BLANCA ESPINO | ENGINEERING | REVIEW | Approv-Cond | Resubmittal Required: The following items must be revised or added to the plan. Please include a response letter with the next submittal that states how all comments have been addressed. 1. Dimension and label Existing private or public right-of-way adjacent to or within the site shall be provided: right-of-way width and recordation data. D.S. 2-05.2.3.C 2. Curb returns with a 25' radii are required from street (Stone Ave.) to P.A.A.L. 3. Indicate a dimensioned cross-section detail of site from south wall to the north wall, identifying each item. 4. Demonstrate vehicle maneuverability fully dimensioned for future refuse location. D.S. 2-05.2.4.T The maximum back-up distance for the collection vehicle shall be forty (40) feet. D.S. 6-01.4.1.C Contact John Clark of Environmental Services @ 791-3175 ext. 1136 to reach an agreement that does not meet Development Standards 6-01 and to obtain a DSMR. 5. Existing and proposed SVT's are to be Near side is 345', Far side is 125'. Correct and revise. |