Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: D03-0035
Parcel: 10511040A

Address:
4302 N ORACLE RD

Review Status: Completed

Review Details: REVISION - DEV PLAN

Permit Number - D03-0035
Review Name: REVISION - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/01/2006 MARILYN KALTHOFF START PLANS SUBMITTED Completed
06/05/2006 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Revise the landscape plan to include inside dimensions for
tree planters in and adjacent to vehicular use areas.
LUC 3.7.2.3.A.1.c
06/09/2006 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: HOME DEPOT RETAIL CENTER: REVISION
D03-0035

Tucson Electric Power Company (TEP) has reviewed the plan submitted June
1, 2006. TEP is unable to approve the plan at this time. There are
existing electrical facilities within the boundaries of this project.
In order for TEP to approve the plan the facilities and easements must
be depicted on the plans.

Enclosed is a copy of a TEP facility map showing the approximate
location of the existing facilities. All costs associated with the
relocation of the facilities in conflict will be billable to the
developer.

Please resubmit two revised bluelines to City of Tucson for TEP's
review. You may contact the area Designer, Warren McElyea at 918-8268
should you have any technical questions. My telephone number is
918-8297.

Sincerely,



Denise Tellez
Scheduling Coordinator

dt
Enclosure
cc: P. Gehlen/F. Rodriguez, City of Tucson (by e-mail)


Denise Tellez
918-8297 DB102
06/13/2006 JCLARK3 ENV SVCS REVIEW Denied * No known landfill with in 1000 feet of this development.
* Single enclosure has insufficient clear area between the side wall protection. Development Standards require ten feet.
* No detail for the double enclosure.
* For the compactor on sheet 3 make sure the center of the compactor is at least seven feet from the building side.
06/15/2006 JIM EGAN COT NON-DSD FIRE Denied Clearly show and label the no build easement on DP2, etc.

Provide recordation information.
06/22/2006 DALE KELCH COT NON-DSD TRAFFIC Approved Traffic Engineering reccomends approval of this development plan.
06/26/2006 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D03-0035 HOME DEPOT RETAIL CENTER/REVISED DEVELOPMENT PLAN
DATE: June 26, 2006



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

NOTE:

1: Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved
Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima
County Addressing prior to assignment of addresses.

2: All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.




jg
06/27/2006 FRODRIG2 PIMA COUNTY WASTEWATER Denied June 26, 2006

To: Thomas Sayler Brown, Sayler-Brown Bolduc Architects, LLC

Thru: Patricia Gehlen, CDRC Project Manager
City of Tucson Development Services Department

____________________________________
From: Michael Harrington (520-740-6579), representing the Pima County
Departments of Wastewater Management and Environmental Quality

Subject: Home Depot Retail Center
Development Plan Revision - 1st Submittal
D03-035

The proposed sewer collection lines for the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.



Sheet DP1: Revise General Note #10, so that it now states:

THE ON-SITE SANITARY SEWERS, EXCEPT PUBLIC SEWERS WITHIN PUBLIC SEWER EASEMENTS OR RIGHTS-OF-WAY, WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS, AND IN ACCORDANCE WITH AN APPROVED OPERATION AND MAINTENANCE PLAN, IF REQUIRED. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT.

Sheet DP1: Add a General Note that states:

THE LANDSCAPING WITHIN ALL PUBLIC SEWER EASEMENTS SHOWN HEREON SHALL BE IN ACCORDANCE WITH THE PLANTING GUIDELINES OF PC/COT STANDARD DETAIL WWM A-4.

Sheet DP1: Add a Permitting Note or General Note that states:

NO PERMITS FOR PERMANENT STRUCTURES (I.E., MASONRY WALLS, FENCES, ETC.) ON OR THROUGH THE PUBLIC SEWER EASEMENT WILL BE ISSUED WITHOUT SEPARATE WRITTEN CONSENT OF PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT.

Sheet DP1: All Sheets: Add the cross-reference case numbers, D06-014 and S05-064, to the REF. NUMBERS block, near the title block of each sheet.

Sheet DP4: Revise the site plan so that:

The existing public sewer plan number, G-2004-161, is added to the labels for the two public sewer manholes and the public sewer 8” main.

This office will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents.

Pima County Code Title 13.20.030.A.2 requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet.

This submittal, a revised subsequent submittal, was made to City of Tucson with no review fees collected or forwarded to the Pima County Development Services Department. Three sheets containing sewerage collection system information have been reviewed. Review fees of $117.00 are now due prior to the approval of the revised development plan submittal.

The next submittal of this project will be the second revised development plan (subsequent) submittal. A check for the review fee of this submittal in the amount of $78.00 (corrections to 2 pages) (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter.

Total fees of $195.00 will be due with the next submittal or prior to approval..

If the number of sheets changes, please adjust the review fee accordingly.


If you have any questions regarding the above mentioned comments, please contact me at the telephone number shown under my signature on the first page of this letter

CC: Project File
06/28/2006 PETER MCLAUGHLIN ZONING REVIEW Denied 1) Revise the handicap curb ramp details (#3, #4 and #5) on sheet DP 7 to show the required truncated domes in place of the scored concrete tactile linear warning grooves.
ANSI
06/29/2006 JOSE ORTIZ ENGINEERING REVIEW Denied Provide the latest revised Grading Plans to confirm that the revisions to the grading plans match the associated revisions to the Development Plans.

If you have any questions, I can be reached at 791-5550 x1191 or Jose.Ortiz@ci.tucsonaz.govs
Jose E. Ortiz
Civil Engineer
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1191 office
(520) 879-8010 fax
06/30/2006 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Denied URBAN PLANNING AND DESIGN COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D03-0035 Home Depot Retail Center 06/29/06

( ) Tentative Plat
() Development Plan (Revised)
() Landscape Plan (Revised)
( ) Revised Plan/Plat
( ) Board of Adjustment
( ) Other (NPPO)

CROSS REFERENCE: SE-03-06

NEIGHBORHOOD PLAN: North Stone Neighborhood Plan

GATEWAY/SCENIC ROUTE: Oracle Rd. is Gateway Route

COMMENTS DUE BY: June 29, 2006

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

( ) No Annexation or Rezoning Conditions, Not an RCP - No Comment
( ) Proposal Complies with Annexation or Rezoning Conditions
( ) RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
( ) No Additional Comments - Complies With Planning Comments Submitted on:
() Resubmittal Required:
( ) Tentative Plat
() Development Plan
( ) Landscape Plan
( ) Other

REVIEWER: Joanne Hershenhorn 791-4505 DATE: June 26, 2006


D03-0035
Home Depot Retail Center (Oracle/Limberlost)


Special Exception (SE) condition 7 requires that all speed tables on Neffson Drive be of a different material that the standard roadway pavement. It appears that they should be concrete pavers, the same as those on Limberlost Drive. Please call out the construction material of the two speed tables on Neffson Drive (sheets DP-2, DP-3 and DP-4).

Along Oracle Road adjacent to lots 3, 4, and 5, please show the sidewalks and pedestrian crossings of ingess/egress areas (on sheets DP-2 and DP-6).

On sheets DP-4 and L-4, please clarify what type of screening will be used north of the 10-foot masonry sound wall (between the basins and drive lane).
07/18/2006 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 18, 2006

Thomas Sayler-Brown
Sayler-Brown Bolduc Lara
1001 North Alvernon Way, Suite 105
Tucson, AZ 85711

Subject: D03-0035 Home Depot Retail Center As-built Development Plan

Dear Thomas:

Your submittal of June 1, 2005, for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

9 Copies Revised Development Plan (Landscape, TEP, ESD, Fire, Wastewater, Zoning, Engineering, Community Planning, DSD)

2 Copies Revised Grading Plan (Engineering, DSD)


Should you have any questions, please call me at 791-5608.

Sincerely,


Patricia Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 620-0535