Permit Number: D03-0028
Parcel: 128111090

Address:
221 S SWAN RD

Review Status: Completed

Review Details: RESUBMITTAL - DEVELOPMENT PLAN

Permit Number - D03-0028
Review Name: RESUBMITTAL - DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/14/2004 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
10/21/2004 BLANCA ESPINO ENGINEERING REVIEW Denied 1. Existing Site Conditions. The following information shall be provided on the development plan drawing to indicate the existing conditions on site and within fifty (50) feet of the site. On sites bounded by a street with a width of fifty (50) feet or greater, the existing conditions across the street will be provided. D.S. 2-05.2.3 Correct and revise.

2. Correct and revise information regarding existing private or public right-of-way adjacent to or within the site shall be provided: existing and future right-of-way width, recordation data, type (private or public) and dimensioned width of paving, curbs, curb cuts, and sidewalks. D.S. 2-05.2.3.A Future right-of-way is 60' half for Swan Road. Indicate water utility.

3. The parking area access lanes (PAALs) shall be designed in accordance with Variance C10-04-11 and letter from Jim Vogelsberg.

4. Indicate all right-of-way dedications on or abutting the site and label. If the development plan has been prepared in conjunction with a subdivision plat or is required as a condition of approval of a review process, such as a rezoning, street dedications in accordance with the Major Streets and Routes (MS&R) Plan may be required by these processes. Should there be any proposed street or alley vacation, provide this information. If vacation has occurred, include the recording information.

5. If street dedication is not required or proposed and the project site is adjacent to a Major Street or Route, draw the Major Street right-of-way lines for those streets. (Add the MS&R future sidewalk, right-of-way lines, etc.)

6. Contact John Clark of Environmental Services @ 791-3175 ext. 1136 to reach an agreement that does not meet Development Standards 6-01 and to obtain a DSMR about the rolling out the trash can to the curb.
10/22/2004 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Provide curbing to protect the required landscaping between the sidewalk and the parking area. Provide curbing or other suitable barrier to protect the landscape border north of the parking area from vehicular damage. LUC 3.7.2.3.B

2) An interior landscape border required along the east property line. A minimum of three canopy trees is required, one for every thirty three feet or fraction thereof. LUC 3.7.2.4

3) Identify any existing vegetation to remain by genus and species. This is important where canopy trees are required. DS 2-07.A.1.e
10/26/2004 DALE KELCH COT NON-DSD TRAFFIC Approved raffic Engineering recommends APPROVAL of this DP.

D. Dale Kelch, EIT
Senior Engineering Associate
Traffic Engineering Division
(520)791-4259x305
(520)791-5526 (fax)
dale.kelch@tucsonaz.gov
10/28/2004 CRAIG GROSS ZONING-DECISION LETTER REVIEW Completed
10/28/2004 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
D03-028
Pueblo Mortgage, Inc.
Development Plan

TRANSMITTAL: October 28, 2004

COMMENTS

1. Revise the future MS&R right-of-way width for Swan Road to be correct (120' full ROW, 60' half ROW) based on MS&R plan. Label the future curb and show future sight visibility triangles if different from the existing shown.

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
10/28/2004 ROGER HOWLETT COT NON-DSD COMMUNITY PLANNING Approved URBAN PLANNING AND DESIGN COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D03-0028 Pueblo Mortgage Inc. 10/28/04

() Tentative Plat
(X) Development Plan
(X) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C9-02-13

NEIGHBORHOOD PLAN: Broadway-Craycroft Area Plan

GATEWAY/SCENIC ROUTE: NO

COMMENTS DUE BY: 10/27/04

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
() See Additional Comments Attached
(X) No Additional Comments - Complies With Planning Comments Submitted on: 8/13/03