Permit Number: D03-0020
Parcel: 13325186H

Review Status: Completed

Review Details: RESUBMITTAL - DEVELOPMENT PLAN

Permit Number - D03-0020
Review Name: RESUBMITTAL - DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
11/07/2003 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
11/07/2003 JIM EGAN COT NON-DSD FIRE Approved The Development Plan is approved 11/7/03.
11/17/2003 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL
BOARD OF ADJUSTMENT VARIANCE COMMENT


TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT:
D03-020
Huntington Park Plaza
Development Plan

TRANSMITTAL: November 17, 2003
DUE DATE: November 20, 2003


1. LUC 3.4.4.1.B.2 requires that, for projects containing more than one building, loading zones must be provided for each building, based on the number of loading spaces required for the uses within each building. This project proposes three buildings, each requiring a loading zone, but only one loading zone is proposed for the project site. Approval of a Board of Adjustment Variance application is required. Once, the variance is approved, add to the general notes the variance case number, date of approval, what was approved, and any conditions imposed.
LUC 3.4.4.1.B.2
DS 2-05.2.2.B.6

2. Revise the loading zone calculations to indicate that 3 spaces (one for each of the proposed buildings) are required per LUC 3.4.4.1.B.2. DS 2-05.2.4.2.4.O

3. For consistency, place the correct name (Huntington Park Plaza) and number (D03-020) of the development plan in the title blocks of the Landscape and Irrigation Plans.
DS 2-05.2.1.G

4. Revise zoning setback table to specify that the stated MS&R setback from Speedway Blvd. is measured from back of future curb.
LUC 3.2.6.5

5. After the provided cross access/ cross parking agreement is recorded, add the recordation information (docket and page numbers) for the agreement to the development plan notes.
DS 2-05.2.4.N

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.


RESUBMITTAL OF THE FOLLOWING ITEMS IS REQUIRED: revised development plan, landscape plan, Board of Adjustment approval letter
11/20/2003 FRODRIG2 LANDSCAPE REVIEW Denied 1) The site must be screened from the residentially zoned property to the south with 5' high masonry wall per LUC Table 3.7.2-I. Per LUC 3.7.3.2.A "Along interior lot lines of the site, the required perimeter screens must be located on the property line...".

2) The loading area must be screened from the adjacent O-3 property and from the adjacent R-1 property with a six foot high masonry wall per LUC Table 3.7.2-I.

Resubmittal of the Development/Landscape Plan is required.
Provide a response letter with the resubmittal.