Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - DEVELOPMENT PLAN
Permit Number - D03-0020
Review Name: RESUBMITTAL - DEVELOPMENT PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/25/2003 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/26/2003 | JIM EGAN | COT NON-DSD | FIRE | Denied | An approved turnaround is required for dead-end P.A.A.L. (Minimum roadway width for P.A.A.L. is 20 feet including all portions of turnaround.) |
| 07/02/2003 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: D03-0020 HUNTINGTON PARK PLAZA/REVISED DEVELOPMENT PLAN DATE: June 26, 2003 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. NOTE: 1. Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2. All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. |
| 07/07/2003 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | DATE: July 7, 2003 To: Craig Gross Planning Administrator FROM: Loren Makus Engineering Division SUBJECT: 8480 East Speedway Blvd. Development Plan D03-0020 (Second Review) T14S, R15E, Section 09 RESUBMITTAL NOT REQUIRED. The Development Plan (DP) and Drainage Report (DR) have been reviewed. At this time the Engineering Division recommends approval of the Development Plan for Huntington Park Plaza. The drainage report was accepted for the purposes of the Development Plan review. If you have any questions, I can be reached at 791-5550 x1161 or lmakus1@ci.tucson.az.us Loren Makus Senior Engineering Associate C:/ 8480 E. Speedway Blvd. |
| 07/07/2003 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approved | WR#106665 July 7, 2003 Mr. Mark Hanshaw Arcadis G & M 285 W. 18th Street Tucson, Arizona 85701 Dear Mr. Hanshaw: SUBJECT: Huntington Park Plaza D03-0020 Tucson Electric Power Company (TEP) has no objections to the Development Plan dated June 24, 2003. As stated in my June 11, 2003, letter to you, there are existing underground electric cable within the area depicted as off-site improvements area north of the subject property, and these facilities will need to be identified by blue stake and pot holed by the customer to assure safety and to determine if relocation is required. Please submit a final set of plans including electrical load plans, to determine how TEP will serve this commercial development. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Mr. Greg Carter Distribution Services - S11 Tucson Electric Power Company P. O. Box 711 Tucson, AZ 85702 Please call me at (520) 884-3879, should you have any questions. Sincerely, S. Glynda Mastrangelo Right-of-Way Agent Land Management sgm cc: Craig Gross, City of Tucson |
| 07/09/2003 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) The site must be screened from the residentially zoned property to the south. LUC 3.7.3 2) Screening per LUC Table 3.7.2-I is required along the west property line to screen the parking area from the adjacent O-3 zoned property north of building 'A' (where no screen currently exists) 3) The loading area must be screened from the adjacent O-3 property and from the adjacent R-1 property with a six foot high masonry wall per LUC Table 3.7.2-I. Resubmittal of the Development/Landscape Plan is required. Provide a response letter with the resubmittal. |
| 07/09/2003 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | TO: Development Services Center Plans Coordination Office FROM: Peter McLaughlin Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: D03-020 Huntington Park Plaza Development Plan 2nd review TRANSMITTAL: July 9, 2003 DUE DATE: July 8, 2003 1. Place the development plan number (D03-020) on all sheets, including the landscape plan and the irrigation plan, in the lower right hand corner near the title block. 2. Pedestrian circulation may not be located between any motor vehicle parking space and the PAAL providing access to that parking space. Please revise pedestrian crosswalk location so that it does not pass behind the southernmost handicap parking space. DS 2-08.4.1.F DS 2-05.2.4.K 3. Revise zoning setback table to specify that the MS&R setback from Speedway Blvd. is the greater of 21 feet or the height of exterior structure wall measured from back of future curb. LUC 3.2.6.5 4. If the site is made up of three lots as shown, the individual lot sizes must be provided. Add these the Floor Area Ratio calculation by adding a column with a heading that reads "lot area". Revise the "area" heading to read "GFA". 5. For projects with multiple lots, they must either be combined, or a cross access/ cross parking agreement must be recorded. Provide a copy of recorded agreement and add the recordation information (docket and page numbers) for the cross access agreement to the development plan notes. DS 2-05.2.4.N 6. Bicycle parking must be evenly distributed and conveniently located at the entrance of each building. On projects with multiple lots/ buildings, bike parking must be provided for each building. Add a bike rack near the front of bldg 2. DS 2-09.4.1 7. Dimension the depth of the backup spur and the distance between the backup spur and the existing fence along the east property line. A minimum 3-foot deep backup spur is required and a minimum of 3 feet is required between the end of the spur and the fence to allow for vehicle overhang. Please revise drawing, which shows only a 2.5 foot overhang. DS 3-05.2.2.D 8. It is acknowledged that a Board of Adjustment Variance application will be submitted to seek relief from the loading zone requirement. Once, the variance is approved, add the variance case number, date of approval, what was approved and conditions to the general notes. LUC 3.4.4.1.B.2 If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. RESUBMITTAL OF THE FOLLOWING ITEMS IS REQUIRED: revised development plan, landscape plan, cross access/cross parking document. |