Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - DEVELOPMENT PLAN
Permit Number - D03-0015
Review Name: RESUBMITTAL - DEVELOPMENT PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/08/2003 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 07/09/2003 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approved | PIMA COUNTY DEVELOPMENT SERVICES DEPARTMENT DEVELOPMENT REVIEW DIVISION 201 N. Stone Avenue, 2nd Floor Tucson, Arizona 85701-1207 CARMINE DEBONIS, JR. Phone: (520) 740-6586 Director FAX: (520) 740-6380 May 23, 2003 TO: Heath Elder, Landmark Engineering THRU: Craig Gross, City of Tucson Development Services FROM: Tim Rowe, P.E., Development Review Engineer (Wastewater) Pima County Development Review Division SUBJECT: A Thru Z Consulting and Distributing Development Plan - 1st Submittal D03–0015 We have reviewed the above-referenced project on behalf of the Pima County Wastewater Management Department. The following comments are offered for your use: 1. Per Pima County Wastewater Management’s Planning Services, there is currently capacity in the existing downstream sewerage system for this development. This response is not to be construed as a commitment for conveyance capacity allocation, but rather an analysis of the existing sewerage system as of this date. 2. Based on our records for the Sunbelt Industrial Center, Lots 1-8 subdivision (C12-86-35), this project would qualify for Participating sewer connection fee rates. 3. All Sheets: Add the development plan case number, D03-0015, to the title block of each sheet. This number should be shown larger or bolder than the cross reference numbers. No wastewater review fees will be charged for sheets where this is the only required revision. 4. Sheet 1: There is an existing public sewer line on this site. Revise General Note 10 to read: ON-SITE SANITARY SEWERS, EXCEPT PUBLIC SEWERS WITHIN PUBLIC SEWER EASEMENTS OR RIGHTS-OF-WAY, WILL BE PRIVATE AND WILL BE CONSTRUCTED, OPERATED AND MAINTAINED ON A PRIVATE BASIS. THE LOCATION AND METHOD OF CONNECTION TO AN EXISTING PUBLIC SANITARY SEWER IS SUBJECT TO REVIEW AND APPROVAL BY THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT AT THE TIME OF SUBMITTAL OF PLUMBING OR BUILDING PLANS. 5. The landscaping on this property over the existing public sewer line must conform to Pima County Wastewater Management’s Sanitary Sewer Landscaping Policies. (See attached copy.) Submit a copy of any landscape plan required for this project to this office with the next submittal, and the required certification stamped and signed by a registered architect. 6. Sheet 1: Replace General Note 16 with one that reads: THE PROPOSED TOTAL NUMBER OF WASTEWATER FIXTURE UNIT EQUIVALENTS FOR THIS PROJECT IS . (with the blank appropriately filled in per Table 13.20.040(F)(1) in Pima County Code 13.20.040(F).) If this proposed total is equal to or greater than 144, a Sewer Service Agreement may be required pursuant to Title 13.20.030. Typically, the Sewer Service Agreement is prepared, and three originals of the Agreement are sent to the Applicant for signature under separate cover, as soon as the proposed total number of wastewater fixture unit equivalents, and all necessary ownership information for the project has been shown. The three signed and notarized originals of the Sewer Service Agreement must be returned to the Development Review Division, before the Mylars of the development plan can be approved. 7. Sheet 2: Show the field-verified rim and invert elevations of existing Manhole 10 in existing public sewer line G-84-74. 8. Sheet 2: Show the correct recording information for the 20' public sewer easement in which public sewer line G-84-74 is located. 9. Sheet 2: Delete the label for a new manhole in existing public sewer line G-84-74 near the southwest corner of the property. None of the private sewer lines connects to this point. 10. Sheet 2: Show the proposed private sewer lines as depicted in the legend on Sheet 1. 11. Sheet 2: Show all of the proposed manholes using the same type and size of symbol. 12. Sheet 2: Show the length and slope of each of the proposed private sewer lines. 13. Sheet 2: Show the size of each HCS line, if it is not 6". 14. Sheet 2: Show the manhole rim elevations for the manholes in the proposed private sewer lines. 15. Sheet 2: The manholes in the private sewer lines must not be in lowlying areas where they will collect and discharge rainwater runoff into the public sewer system. Show a sufficient number of finished spot grade elevations to demonstrate that rainwater runoff will not collect over the manholes. 16. We will require a complete set of the revised bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Ordinance 2003-29 went into effect on April 11, 2003. This ordinance requires that a wastewater review fee be paid for each submittal of a development plan or subdivision plat. The review fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the second (2nd) submittal. The new wastewater review fees will apply to two of three sheets of the development plan, and all sheets of any landscaping plan required for this project. Please include a check for the appropriate amount (made out to PIMA COUNTY TREASURER) with the revised set of bluelines and response letter for the wastewater review fees If other sheets are revised in such a manner that the sewer design is impacted, please adjust the review fee accordingly. If you wish to discuss the above comments, please contact me at 740-6563. Tim Rowe, P.E., Development Review Engineer (Wastewater) Pima County Development Review Division TR/tr Copy: Project |
| 07/09/2003 | JIM EGAN | COT NON-DSD | FIRE | Approved | The Development Plan is approved 7/9/03. |
| 07/09/2003 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approved | PIMA COUNTY DEVELOPMENT SERVICES DEPARTMENT DEVELOPMENT REVIEW DIVISION 201 N. Stone Avenue, 2nd Floor Tucson, Arizona 85701-1207 CARMINE DEBONIS, JR. Phone: (520) 740-6586 Director FAX: (520) 740-6380 August 8, 2003 TO: Heath Elder, Landmark Engineering THRU: Craig Gross, City of Tucson Development Services FROM: Subhash Raval, P.E., Division Manager Pima County Development Review & Technical Services Division (Wastewater) SUBJECT: A Thru Z Consulting and Distributing Development Plan - 2nd Submittal D03–0015 We have reviewed the above-referenced project on behalf of the Pima County Wastewater Management Department. The following comments are offered for your use: 1. Your response letter dated June 24, 2003 did not address comment #7 of Tim Rowe’s letter. Were the invert and rim elevations field verified? 2. As the proposed sewer is going under Building No. 1 our concern is the ability to repair and maintenance of the line. We recommend that you increase the size of sewer to 8" from the existing manhole for 466 l.f. and provide a manhole at the end of the line. Buildings three and four can have a HCS go into this new manhole (ADEQ has this requirement). 3. Explain how you calculated 137 fixture units. If this proposed total is equal to or greater than 144, a Sewer Service Agreement may be required pursuant to Title 13.20.030. Typically, the Sewer Service Agreement is prepared, and three originals of the Agreement are sent to the Applicant for signature under separate cover, as soon as the proposed total number of wastewater fixture unit equivalents, and all necessary ownership information for the project has been shown. The three signed and notarized originals of the Sewer Service Agreement must be returned to the Development Review Division, before the Mylars of the development plan can be approved. 4. We will require a complete set of the revised bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. Pima County Ordinance 2003-29 went into effect on April 11, 2003. This ordinance requires that a wastewater review fee be paid for each submittal of a development plan or subdivision plat. The review fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the third submittal. Please include a $117.00 check for the wastewater review fees (made out to PIMA COUNTY TREASURER) with the revised set of bluelines and response letter. If other sheets are revised in such a manner that the sewer design is impacted, please adjust the review fee accordingly. If you wish to discuss the above comments, please contact me at 740-6586. Subhash Raval, P.E., Division Manager Pima County Development Review & Technical Services Division (Wastewater) SR/SR/dk Copy: Project |
| 07/09/2003 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: D03-0015 A THRU Z / REVISED DEVELOPMENT PLAN DATE: July 9, 2003 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. NOTE: 1. Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2. All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. |
| 07/21/2003 | DAN CASTRO | ZONING | REVIEW | Approv-Cond | The Zoning Review Section approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 1. To assure pedestrian access to right-of-way for Phase I, please indicate graphically and by note the required pedestrian circulation path from Phase I building to right-of-way. 2. Building 3 shows a proposed use of wholesale on sheet 1 of 3 and manufacturing on sheet 2 of 3. Revise for consistency. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608. |
| 07/21/2003 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | |
| 07/21/2003 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | Revise the landscape plan schedule to include all symbols shown on the plan. Revise the plans to use an appropriate symbol for transplanted trees; it appears that the symbol is used for existing trees along Old Vail Road. |
| 07/21/2003 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approved | TO: Craig Gross FROM: Laith Alshami, P.E. CDRC Engineering SUBJECT: A Thru Z D03-0015, T15S, R15E, SECTION 28 RECEIVED: Development Plan, Landscape Plan and Drainage Report on July 08, 2003 The subject project has been reviewed. The Drainage Report and the Landscape Plan are acceptable. The Development Plan is recommended for approval pertaining to Engineering and Floodplain. The following information shall be addressed on the Grading Plan: 1. Show roof drainage and sidewalk scuppers. 2. Provide a soils report which addresses percolation rates for the proposed retention basins and the stability of any proposed slopes. 3. Additional information concerning detention/retention basin Security Barriers may be required on the Grading Plan. 4. If there is not existing sidewalks along Old Vail Road frontage, sidewalks will be required to be shown on the Paving Plans. Please be advised that additional drainage and engineering information may be required on the Grading Plan. If you have any questions, I can be reached at 791-5550 or lalsham1@ci.tucson.az.us |