Permit Review Detail
Review Status: Completed
Review Details: REVISION - DEV PLAN
Permit Number - D03-0009
Review Name: REVISION - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/18/2007 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/22/2007 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | June 22, 2007 TO: Kathryn McGuire, Architect THRU: Patricia Gehlen, CDRC Manager City of Tucson Development Services Department _____________________________________ FROM: Tom Porter.,Sr. Civil Eng. Development Review Division (Wastewater) Pima County Development Services Department SUBJECT: Specialists in Dermatology, Phase 2 Development Plan – 3rd Submittal D03-009 The proposed sewer collection lines to serve the above-referenced development have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ), and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. Sheet D-3.1: Show the public and private sewer lines using different line-types, so that they can readily be distinguished from each other. Also, show and describe examples of these different line types in a legend. Sheet D-3.1: The existing private BCS should be clearly marked as such. Also the slope/length/ size and material of the BCS should be shown on plan. Sheet D-3.1: Add a General Note that states: THE ON-SITE SEWERS ARE EXISTING AND PRIVATE. NO NEW SEWERS ARE PROPOSED. All existing public sewer elements (manholes, cleanouts and mains), that are located adjacent to and less than 100’ from this project, are identified with the IMS numbers and construction plan numbers. The IMS numbers are the sewer element identification numbers that can be found on the PCWMD Maps and Records (5th floor) base maps or on PCWMD and PCDOT Map Guide websites. Sheet D-3.1: The sewer directional flow arrows need to be shown on the existing public sewer line and BCS. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal of the development plan. The required revision(s) may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you have any questions regarding the above comments, please do not hesitate to contact me. Sincerely, Tom Porter Telephone: (520) 740-6579 Copy: Project file |
| 06/26/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D03-0009 Specialists in Dermatology Development Plan Resubmittal TRANSMITTAL DATE: June 22, 2007 DUE DATE: July 17, 2007 COMMENTS: The Zoning Review Section approves the development plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 74960. KAA S:\zoning review\karol\planning\cdrc\developmentplan\D03-0009dpr1.doc |
| 06/27/2007 | PATRICIA GILBERT | ENGINEERING | REVIEW | Approved | |
| 06/29/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Approv-Cond | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES June 29, 2007 Kathryn McGuire Kathryn McGuire, Architect, LLC. 4000 South Javelina Run Tucson, Arizona 85730 Subject: D03-0009 Specialist in Dermatology Revised Development Plan Dear Kathy: The above referenced development plan has been CONDITIONALLY APPROVED by the Community Design Review Committee. Once the necessary corrections are made per on-line, please submit the following documents for sign-off. 1 Double Matte right-reading Océ or Photo Mylar of the COMPLETE SET of the Development Plan, Landscape Plan, and the Native Plant Preservation Plan (if part of the original submittal). AND 1 Double Matte right-reading Océ or Photo Mylar of the Development Plan. The extra Double Matte right-reading Océ or Photo Mylar that you submit will be delivered to Pima County for permanent recording. Additional blackline copies will be made from the complete mylar set and distributed to various review agencies for their files. These copies will be ordered from the City's contracted print company and billed to you unless you already have an account at another printing company. Please let us know which printing company you would prefer to use and list them on your attached transmittal form when submitting your mylars to the CDRC office for sign-off approval. Your printing company will deliver the mylar and two (2) blackline copies to your office. If you are out of town you will need to contact the printing company for pick up or mailing arrangement options. TO ENSURE A MORE RAPID REVIEW OF THE MYLARS, PLEASE HAVE THE CITY OF TUCSON APPROVAL STAMP PLACED ON EACH SHEET OF THE SUBMITTAL SET, PREFERABLY IN THE LOWER RIGHT HAND CORNER NEAR THE TITLE BLOCK. THE STAMP IS LOCATED AT http://www.ci.tucson.az.us/dsd/CDRC Rezoning/CDRC/CDRC Stamp/cdrc stamp.html. THE MYLAR MUST BE REVIEWED AND APPROVED BY PIMA COUNTY WASTE ATER PRIOR TO SUBMITTAL TO THE CDRC OFFICE. PIMA COUNTY WASTEWATER MUST PROVIDE A WRITTEN APPROVAL DOCUMENT (E-MAIL IS SUFFICIENT). Should you have any questions, please call me at 837-4919. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 296-2735 dpapproved |