Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - DEVELOPMENT PLAN
Permit Number - D03-0003
Review Name: RESUBMITTAL - DEVELOPMENT PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/17/2004 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 05/24/2004 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: D03-0003 A-ATLAS SELF STORAGE/REVISED DEVELOPMENT PLAN DATE: May 20, 2004 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project. NOTE: Approved with condition that Existing Office Building is labeled with a building number on approved mylar. 1. Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima County Addressing prior to assignment of addresses. 2. All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. |
| 05/26/2004 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | COMPREHENSIVE PLANNING TASK FORCE COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D03-0003 A-Atlas Self Storage 05/25/04 () Tentative Plat ( ) Development Plan ( ) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: C9-89-39 NEIGHBORHOOD PLAN: General Plan GATEWAY/SCENIC ROUTE: COMMENTS DUE BY: May 31, 2004 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies ( ) See Additional Comments Attached ( ) No Additional Comments - Complies With Planning Comments Submitted on: 02/11/03 ( ) No Resubmittal Required: () Tentative Plat ( ) Development Plan ( ) Landscape Plan () Other REVIEWER: JBeall 791-4505 DATE: 5/25/04 COMPREHENSIVE PLANNING TASK FORCE COMMENTS |
| 05/28/2004 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) Revise the development plan to continue the 6" vertical curb along the perimeter of the vehicular use area in the vicinity of building 13. DS 3-05.2.3.C.1 2) Provide a barrier per DS 3-05.2.3.C.1 on both sides of the new entrance. 3) Decomposed granite or other suitable dust control treatment will be required for any offsite or onsite disturbance related to the project, such as utility installation. RESUBMITTAL OF THE LANDSCAPE PLAN AND DEVELOPMENT PLAN IS REQUIRED. |
| 06/01/2004 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Craig Gross DATE: June 1, 2004 Zoning Administrator SUBJECT: 8325 E. Golf Links Road Development Plan D03-0003 (Second Review) T14S, R15E, Section 21 RESUBMITTAL REQUIRED: Development Plan and Drainage Report. The Development Plan (DP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Development Plan: 1. Please include a response letter to the comments along with the corrected copies with re-submittal. 2. Please provide property description per D.S. 2-02.2.1.3. 3. Please coordinate with TDOT for updating the Bus shelter per rezoning condition 30.15. 4. Please remove the retention basin and continue the 30' dedication of the Atturbury Wash linear park Northward. 5. Show the limits of the 100-year floodplain and water surface elevation for the Pantano and Atturbury Wash on the DP per D.S. 2-02.2.1.15. 6. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. 7. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0. Please obtain permission from John Clark at Environmental Services for placement and number of refuse containers at 791-5543. Drainage Report: 1. The Drainage report was reviewed for A-Atlas Self-Storage DP purposes only. The final acceptance will be given at the grading plan stage. If you have any questions, I can be reached at 791-5550 x1193 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax |
| 06/01/2004 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Peter McLaughlin Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: A-Atlas Self Storage D03-003 Development Plan TRANSMITTAL: June 1, 2004 DUE DATE: May 31, 2004 1. Place the development plan number, D03-003, on each sheet, including sheets I-1, I-2 and W-1. DS 2-05.2.1.K 2. Provide copy of zoning approved lot reconfiguration documents. D.S. 2-05.2.4.A 3. In order to be legible on microfilm the minimum required text size is 12 (0.12") for archiving purposes. Much of the lettering on sheet 3 of 3 does not meet this minimum standard. Please revise text to be a minimum of 12 point. DS 2-05.2.1.C 4. Provide a copy of recorded access easement from Golf Links Road. Add docket and page of recordation for this and any other easements. DS 2-05.2.3.B 5. Fully dimension the width of the pedestrian circulation system on the plan. A minimum 5-foot pedestrian refuge, including a 4-foot sidewalk is required between the PAAL and office buildings. A 6" vertical curb is required to provide physical separation between the PAAL and pedestrian refuge. DS 3-05.2.2.B.1 DS 2-08.4.1.A 6. It is understood that approval of an LDO is being sought for the northeast property line adjacent to the SR-zoned Pantano Wash. Provide a copy of LDO approval documents prior to development plan approval. LUC 3.2.6.4 If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608. |
| 06/04/2004 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | Traffic Engineering recommends APPROVAL of this DP D. Dale Kelch, EIT Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |
| 06/09/2004 | GLENN HICKS | COT NON-DSD | PARKS & RECREATION | Approved | |
| 06/14/2004 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Denied | June 14, 2004 TO: Dan White, Physical Resource Engineering, Inc. THRU: FROM: ____________________________________ representing the Pima County Departments of Wastewater Management and Environmental Quality SUBJECT: A-Atlas Self-Storage - Golf Links Rd. - Submittal D03-003 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use. ALL SHEETS. Add the project number, D03-0003, to the title block of each sheet. This number should be shown larger or bolder than any cross-reference numbers. SHEET 1. Add the following permitting note A PROJECT CONSTRUCTION PERMIT MUST BE SECURED FROM PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT BEFORE BEGINNING ANY WORK ON THIS PROJECT. SHEET 2. Show the Pima County plan number for the existing 18-inch public sewer line along the west side of the property. SHEET 2. Show the sewer connection to the existing building. If sewer is private and existing, please label it as such. If the sewer is private and proposed, please label it as such. We will require a revised set of bluelines, and a response letter, addressing these comments. Additional comments may be made during the review of these documents. County Ordinance 2003-29 went into effect on April 11, 2003. This ordinance requires that a wastewater review fee be paid for each submittal of the development plan. The fee for the first submittal is $166 plus $50 per sheet. For the second submittal, the review fee is $50 per sheet. For all subsequent submittals, the review fee is $39 per sheet. The next submittal of this project will be the third (3rd) submittal. A check for the review fee of this submittal in the amount of $78.00 (made out to PIMA COUNTY TREASURER) must accompany the revised set of bluelines and response letter. If the number of sheets changes, please adjust the review fee accordingly. If you wish to discuss the above comments, please contact me at the phone number provided above, under my signature. |