Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - DEVELOPMENT PLAN
Permit Number - D02-0038
Review Name: RESUBMITTAL - DEVELOPMENT PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/29/2004 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 02/10/2004 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 02/10/2004 | TIM ROWE | PIMA COUNTY | WASTEWATER | Approved | February 10, 2004 TO: Steve Gregor, P.E., Gregor & Grenier Engineering, Inc. THRU: Craig Gross, City of Tucson Development Services FROM: Tim Rowe, P.E., Development Review Engineer (representing Pima County Wastewater Management and Environmental Quality) Pima County Development Review Division SUBJECT: Shopping Center - NWC Rita Road and Houghton Road Development Plan - 3rd Submittal D02-0038 The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management (PCWWM) Department. This review letter may contain comments pertaining to the concerns of either Department. Separate review letters from PDEQ and PCWWM representatives will not be prepared for this project. The following comments are offered for your use: 1. Sheet 1: The descriptions of the linetypes used to show the proposed sewers and the proposed water lines have been reversed in the legend. Revise as necessary. 2. Subject to the above, the Pima County Department of Environmental Quality and Wastewater Management Department hereby approve the above referenced submittal. The required revision(s) may be shown on the Mylars. Please note the following: Approval of the above referenced submittal does not authorize the construction of public or private sewer collection lines, or water distribution lines. Prior to the construction of such features, a Construction Authorization (Approval To Construct) may need to be obtained from the Pima County Environmental Quality. Also, air quality activity permits must be secured by the developer or prime contractor from the Pima County Department of Environmental Quality before constructing, operating or engaging in an activity which may cause or contribute to air pollution. If you wish to discuss the above comments, please contact me at 740-6563. Tim Rowe, P.E., Development Review Engineer (Wastewater) Pima County Development Review Division TR/tr Copy: Project |