Permit Review Detail
Review Status: Completed
Review Details: REVISION - DEV PLAN
Permit Number - D02-0038
Review Name: REVISION - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/03/2007 | LAITH ALSHAMI | ENGINEERING | REVIEW | Denied | Laith Alshami, Engineering and Floodplain Review, 01/03/2007 TO: Patricia Gehlen FROM: Laith Alshami, P.E. CDRC Engineering SUBJECT: The Shoppes at Rita Ranch: Revision D02-0038, T15S, R15E, SECTION 26 RECEIVED: Development Plan on December 29, 2006 The subject project has been reviewed. We offer the following comments: Development Plan: 1. It is not clear what the wash basins will be used for and how will they drain. Additionally, the basins may need oil/water separators before they discharge into the sewer. The basins require also roofs to protect them from rain water. 2. Add invert elevations and additional grades on Details 7/3 and 13/3 to clarify the proposed drainage directions. Additionally, provide a detail for the proposed clean out. 3. What is the purpose of the proposed 6-foot curb opening south of building 4? It appears that it is proposed in front of the sidewalk around the building. 4. The attached email does not properly address the drainage modifications shown east of Building "1". Address the changes and provide sufficient information, dimensions and details. RESUBMITTAL REQUIRED: Revised Development Plan |
| 01/11/2007 | KAROL ARAGONEZ | ZONING | REVIEW | Approved | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Karol Aragonez Planner PROJECT: D02-0038 The Shoppes at Rita Ranch Revision Development Plan TRANSMITTAL DATE: January 11, 2007 DUE DATE: January 29, 2007 COMMENTS: The Zoning Review Section approves the development plan for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. If you have any questions about this transmittal, please call Karol Aragonez, (520) 791-5550, ext. 1197. KAA S:\zoning review\karol\planning\cdrc\developmentplan\D02-0038dp.doc |
| 01/29/2007 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 01/31/2007 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES January 31, 2007 Steven Gregor, P.E. Gregor Engineering, Inc 5232 East Pima Street, Suite A Tucson, Arizona 85712 Subject: D02-0038 The Shoppes at Rita Ranch Revised Development Plan Dear Steve: Your submittal of December 29, 2006 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter explaining how each outstanding requirement has been addressed: ALL BLACKLINES MUST BE FOLDED 2 Copies Revised Development Plan (Engineering, Zoning, DSD) Should you have any questions, please call me at 791-5608 extension 1179. Sincerely, Patricia Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 292-6144 dp-resubmittal |
| 12/28/2006 | MARILYN KALTHOFF | START | PLANS SUBMITTED | Completed |