Permit Review Detail
Review Status: Completed
Review Details: CDRC RESUBMITTAL - DEVELOPMENT PLAN
Permit Number - D02-0037
Review Name: CDRC RESUBMITTAL - DEVELOPMENT PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/13/2003 | FERNE RODRIGUEZ | START | INITIALIZE THE WORKFLOW | Completed | |
| 01/13/2003 | FRODRIG2 | PIMA COUNTY | WASTEWATER | Approv-Cond | PIMA COUNTY DEVELOPMENT SERVICES DEPARTMENT DEVELOPMENT REVIEW DIVISION 201 N. Stone Avenue, 2nd Floor Tucson, Arizona 85701-1207 CARMINE DEBONIS, JR. Phone: (520) 740-6586 Director FAX: (520) 740-6380 January 31, 2003 TO: David Tannous, Sayler-Brown Bolduc Architects, L.L.C. THRU: Craig Gross, City of Tucson Development Services FROM: Subhash Raval, P.E., Manager Pima County Development Review & Technical Services Divisions (Wastewater) SUBJECT: Rita Ranch Retail Center Development Plan - 2nd Submittal D02-037 We have reviewed the above-referenced project on behalf of the Pima County Wastewater Management Department. The following comments are offered for your use: 1. Replace General Note #’21-C with the following: ANY WASTEWATER DISCHARGED INTO THE PUBLIC SANITARY SEWERAGE SYSTEM SHALL MEET THE REQUIREMENTS OF THE INDUSTRIAL WASTE ORDINANCE (PIMA COUNTY ORDINANCE NO. 1991-140, AS AMENDED). 2. Provide invert information for new manhole. Be advised, the location of the new manhole must not conflict with the storm sewer pipe. 3. Provide blue lines with the above corrections. 4. Subject to the above, the Development Plan is approved. If you wish to discuss the above comments, please contact Tim Rowe at 740-6563. Subhash Raval, P.E., Division Manager Pima County Development Review & Technical Services Divisions (Wastewater) SR/SR/dk Copy: Project |
| 01/21/2003 | KAY MARKS | PIMA COUNTY | ADDRESSING | Approved | PIMA COUNTY DEVELOPMENT SERVICES DEPARTMENT 201 N. Stone Ave, 1st Floor Tucson, Arizona 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO : CITY PLANNING FROM : KAY MARKS, ADDRESSING OFFICIAL SUBJECT : D02-0037 RITA RETAIL SHOPPING CENTER/ REVISED DEVELOPMENT PLAN DATE : January 21, 2003 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/ addressing, and we hereby approve this project. NOTE: 1. Submit a 24 x 36 Mylar of approved Development Plan to City Planning. Signed and dated mylar will be forwarded to Pima County Addressing prior to the assignment of addresses. 2. All addresses will need to be displayed per Pima County Address Standards at the time of final inspection. |
| 01/23/2003 | LAITH ALSHAMI | DEVELOPMENT SERVICES | ENGINEERING | Approved | Laith Alshami, Engineering and Floodplain DATE: January 22, 2003 TO: Craig Gross FROM: Laith Alshami, P.E. CDRC Engineering SUBJECT: Rita Retail Shopping Center D02-037, T15S, R15E, SECTION 26 RECEIVED: Development Plan, Drainage Report and Landscape Plan on January 13, 2003 The subject project has been reviewed. The Drainage Report is acceptable for Development Plan Purposes. The Development Plan is recommended for conditional approval pertaining to Engineering and Floodplain subject to providing the proper verification which demonstrates that proposed drainage solutions which occur outside the boundaries of the subject development comply with the requirements of D.S. 2-05.2.4.H.5. Landscape Plan is acceptable pertaining to Engineering and Floodplain. |
| 01/23/2003 | PETER MCLAUGHLIN | DEVELOPMENT SERVICES | ZONING | Approv-Cond | TO: Development Services Center Plans Coordination Office FROM: Peter McLaughlin Plans Coordination Office Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: D02-037 Rita Ranch Retail Center Development Plan TRANSMITTAL: January 23, 2003 DUE DATE: January 27, 2003 The Zoning Review Section approves the development plan for this project, subject to the following change on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements. 1. A Scenic Corridor Zone (SCZ) application has been submitted and must be approved prior to development plan approval. Include the SCZ case number (SCZ-02-14), date of approval, approved colors and conditions in the general notes. DS 2-05.2.2.B.10 2. The drawing indicates that there are seven class 1 and six class 2 bicycle parking spaces provided, but only twelve spaces are indicated in the bicycle parking calcs. Please revise to be consistent. DS 2-05.2.4.Q 3. Provide docket and page information for the easements to be recorded. DS 2-05.2.3.B 4. This site is a portion of a lot. Please provide lot split documentation showing approval from the zoning review section. If you have any questions about this transmittal, please call Peter McLaughlin, (520)791-5608. |
| 01/28/2003 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | Traffic Engineering recommends APPROVAL of this DP. The consultant should note: 1. The far side SVT's for the entrances onto Rita Road need only be 30' pedestrian SVT's as there is a median divider on Rita Road. Refer to Development standard 3-01.5.1.B.1 2nd paragraph. This plan is acceptable as is because the far side SVT's are conservative. D. Dale Kelch, EIT Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dkelch1@ci.tucson.az.us |