Permit Number: D02-0028
Parcel: 140410770

Review Status: Completed

Review Details: CDRC - DEVELOPMENT PLAN

Permit Number - D02-0028
Review Name: CDRC - DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/29/2002 FERNE RODRIGUEZ START INITIALIZE THE WORKFLOW Approved
08/30/2002 JIM EGAN CITY OF TUCSON - NOT DSD FIRE Approved THE DEVELOPMENT PLAN IS APPROVED. 8/30/02
09/04/2002 KAY MARKS PIMA COUNTY ADDRESSING Approved TO : CITY PLANNING
FROM : KAY MARKS, ADDRESSING OFFICIAL
SUBJECT : D02-0028 UNIVERSAL AVIONICS/DEVELOPMENT PLAN
DATE : September 3, 2002


***********************************************************************************************************

The above referenced project has been reviewed by this Division for all matters pertaining to street naming/ addressing, and the following matters must be resolved prior to our approval:



1.) Label section corners on Location Map.

2.) Correct Lots 69 & 76 to Lots 69-76.
09/04/2002 KAY MARKS PIMA COUNTY ADDRESSING Approved Comments on file.
09/12/2002 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved NO COMMENT
D02-0028
KEVIN MORROW
UNIVERSAL AVIONICS
09/24/2002 BLANCA ESPINO DEVELOPMENT SERVICES ENGINEERING Approved 1. The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks. D.S. 2-05.2.3.C

2. 3. Provide locations and types of drainage structures, such as, but not limited to, drainage crossings and pipe culverts. D.S. 2-05.2.4.H.3 (Check for emergency spillways, security barriers and access into basin (s) for maintenance. (A minimum of one 15-foot-wide vehicular access ramp shall be provided into each basin. The maximum roadway or access ramp slope shall not exceed 15 percent. Alternate means of access will be reviewed by the City Engineer on a case-by-case basis. SMDDFM 14.3.3 & 4 and 2.3.1.6.C)).

3. Show refuse collection areas, including locations of dumpsters, screening location and materials, and vehicle maneuverability, fully dimensioned. For specific information on refuse collection, refer to Development Standard 6-01.0. Refuse collection on all projects shall be designed based on that Standard, even if collection is to be contracted to a private firm. Adherence to the Standard is to assure: D.S. 2-05.2.4.T

o provision for on-site collection and maneuvering to avoid on-street traffic conflicts; demonstrate solid waste truck maneuverability to all proposed refuse collection areas.
o minimum conflict with pedestrian and vehicular traffic along streets and on-site.

4. Proposed fills in excess of two feet above existing grade at any location n the outer one hundred feet of the developing site adjacent to residentially zoned property require the procedure outlined in IBC Chapter 36, Section 13.1. This process must be complete prior to Grading Plan approval.

5. Roof drainage for building #4 needs to be addressed (show direction of flow). Indicate downspouts and show drainage concepts.

6. Indicate location of downspouts on proposed building.

Drainage Statement
1. Drainage statement, Figure A-3 indicates the southern west basin to be detention/retention. The development plan indicates this basin to be retention only. The basin indicated on development plan and drainage statement need to match.

2. Figure A-3 the northern west detention basin indicates 3 outlets. I inspected this site on September 19, 2002 and only 2 outlets exist. Please make corrections on development plan and drainage statement.

3. A Grading Plan and Permit will be required. Proposed grading in excess of 5,000 yards is designated "engineered grading" and a soils engineering report is required with the Grading Plan submittal. IBC Chapter 36, Section 9. The Soils Report must also address the requirements detailed in the S.M.D.D.F.M., 14.2.6

4. Proposed developments exceeding 5 acres are subject to NPDES requirements. Contact Loren Makus, 791-4251 for submittal requirements.

5. The storm drain in Figure A-3 needs to be addressed on development plan.

6. As per the cross section A1, it indicates that the trench is 2 ft. wide x 2 ft. deep with a WSE of 1.54 ft. with no grate or cover. Indicate what type of cover will be used for vehicle and pedestrian traffic.

7. Address the southwest basin in drainage statement. Indicate retention basin calculation, dimensions, size of slopes, top/bottom elevations, water surface elevation and two cross section details.

8. Is existing berm of the northern west detention basin too close to building? Will it be modified where the runoff will flow into the basin? Indicate top and side elevations of berm.
09/24/2002 CDRC Review Process OTHER AGENCIES PIMA ASSN OF GOVTS Approved Transportation Information for Subdivision and Development Pima Association of Governments
Review Requests
Transportation Planning Division

CASE #: D02-0028 177 N. Church Avenue, Suite 405

NAME: Universal Avionics Tucson, AZ 85701
Phone: (520) 792-1093
DATE: 9/23/2002
STREET NUMBER 1
Nearest Existing or Planned Major Street Valencia (Country Club to Palo Verde)
Is improvement planned as part of the 5-Year Transportation
Improvement Program? No
Year:
Planned Action:
Existing Daily Volume – Based on Average Daily Traffic 37,500
Existing Daily Capacity- Level of Service “E” 63,000 Existing Number of Lanes: 6
Future Daily Volume - Adopted Plan System Completed 44,935
Future Daily Capacity - Level of Service “E” 63,000 Future Number of Lanes: 6
Estimated Traffic Generation for Proposed Development 638
(Expressed in Average 24 Hr. Vehicle Trips)
Present Bus Service (Route, Frequency, Distance) Route 11, 15 minutes, 0.25 miles
Existing or Planned Bikeway Planned bike route with striped shoulder
Remarks:
STREET NUMBER 2
Nearest Existing or Planned Major Street
Is improvement planned as part of the 5-Year Transportation
Improvement Program? No
Year:
Planned
Existing Daily Volume – Based on Average Daily Traffic 0
Existing Daily Capacity- Level of Service “E” 0 Existing Number of Lanes: 0
Future Daily Volume - Adopted Plan System Completed 0
Future Daily Capacity - Level of Service “E” 0 Future Number of Lanes: 0
Present Bus Service (Route, Frequency, Distance)
Existing or Planned Bikeway
Remarks:
09/24/2002 BLANCA ESPINO DEVELOPMENT SERVICES ENGINEERING Approved Comments on file
09/26/2002 GLENN HICKS CITY OF TUCSON - NOT DSD PARKS & RECREATION Approved DATE: September 25, 2002

TO: Ferne Rodriguez, Development Services

FROM: Glenn Hicks, Senior Planner, Parks and Recreation

RE: CDRC Transmittal, Project D02-0028 Universal Avionics


CC: Craig Gross, Development Services



Staff has reviewed and approved.
09/26/2002 JOE LINVILLE DEVELOPMENT SERVICES LANDSCAPE Approved The Landscape Section does not recommend approval of the Development Plan at this time.

1) Revise the development plan calculations on DP1 to more accurately desribe the landscape requirements. Landscape borders and screening are required elements. If borders and screening are existing, please indicate.

2) Identify the existing trees on the site. DS 2-07.2.0

3) Revise the text to a minimum of .012 point on sheet L.1 where necessary.

4) Show the required velvet mesquites on the landscape plan and indicate the quantity in the legend in order to comply with native plant preservation requirements. DS 2-15.3.4

Resubmittal of the Development Plan/Landscape Plan is required.
09/26/2002 CDRC Review Process CITY OF TUCSON - NOT DSD REAL ESTATE Approved No objection
09/26/2002 JOE LINVILLE DEVELOPMENT SERVICES LANDSCAPE Approved Comments on file.
09/26/2002 ZELIN CANCHOLA CITY OF TUCSON - NOT DSD ENGINEERING - TRAFFIC Approved Traffic engineering recommends approval of the development plan D02-0028.
09/26/2002 JOE LINVILLE DEVELOPMENT SERVICES NPPO Approved
09/26/2002 CDRC Review Process DEVELOPMENT SERVICES ZONING Approved COMMENTS
CODE SECTION/ DEVELOPMENT STANDARD

1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is August 28, 2003.

2. Per Pima County Assessors records, this site is comprised of eight (8) lots. City of Tucson lot combination approval is required for this site. A copy of the lot combination covenant prepared by the City Attorney's Office must be recorded and a copy submitted to the Zoning Review Section prior to development plan approval. Please contact me at the number listed at the bottom of these comments to make arrangements for you to receive a copy of the covenant.

3. In your response letter to these comments, please include how this project complies with the "subject to" criteria listed under LUC Sec. 3.5.5.1.B, .F, .G, and .H.


4. This project has been assigned development plan case number D02-028. Please note the case number on the lower right corner of each sheet on all plans.
D.S. 2-05.2.2.B.2

5. Provide, as a note, the square footage of each building on sheet DP-2.
D.S. 2-05.2.4.M

6. On the drawing (sheet DP-2), label the heights and dimension of all structures.
D.S. 2-05.2.4.N

7. Show all loading zones fully dimensioned. Only three (3) of the four (4) required, are labeled on the drawing.
D.S. 2-05.2.4.O

8. All requested changes must be made to the development and landscape plans.
D.S. 2-07.2.1.A
09/26/2002 CDRC Review Process DEVELOPMENT SERVICES ZONING Approved October 18, 2002

The Zoning Review Section approves the development plan for this project.

Dan Castro, Senior Planner
10/04/2002 CDRC Review Process CITY OF TUCSON - NOT DSD COMMUNITY PLANNING Approved COMMUNITY PLANNING AND PRESERVATION COMMENTS

Regarding

SUBJECT: Community Design Review Committee Application

CASE NUMBER: CASE NAME: DATE SENT

D02-0028 Universal Avionics 09/12/02

( ) Tentative Plat
( ) Development Plan
( ) Landscape Plan
() Revised Plan/Plat
() Board of Adjustment
() Other

CROSS REFERENCE: C15-88-1

NEIGHBORHOOD PLAN: General Plan

GATEWAY/SCENIC ROUTE: N/A

COMMENTS DUE BY: September 26, 2002

SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS:

() No Annexation or Rezoning Conditions, Not an RCP - No Comment
() Proposal Complies with Annexation or Rezoning Conditions
() RCP Proposal Complies With Plan Policies
( ) See Additional Comments Attached
() No Additional Comments - Complies With Planning Comments Submitted on:
() No Resubmittal Required
() Tentative Plat
( X ) Development Plan
() Landscape Plan
() Other

REVIEWER: JBeall DATE: 9-6-02

Community Planning and Preservation Comments
Universal Avionics, D02-0028



This development plan must be in compliance with annexation zoning conditions from ordinance no. 7025 adopted on September 6, 1988, Country Club/Valencia annexation district.


1. The proposed project site as indicated on the zoning base maps has a zoning classification of, I-1 ®, which is subject to the following conditions:

4. The I-1 ® portions shall be limited to a height of 39 feet and restricted by prohibiting the uses in Attachment B. [Zoning Ordinance No. 7090]

Please address these conditions on the development plan in the General Notes section by including the following notes:

The maximum building height is to be restricted to 39 feet, per zoning ordinance 7090.

(30) The following uses are prohibited in I-1 zoning as part of zoning ordinance 7090, see Attachment B for prohibited uses.
10/04/2002 CDRC Review Process CITY OF TUCSON - NOT DSD COMMUNITY PLANNING Approved Comments on file.
10/09/2002 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved COMMENTS ON FILE
10/09/2002 TIM ROWE PIMA COUNTY WASTEWATER Approved PIMA COUNTY
DEVELOPMENT SERVICES DEPARTMENT
DEVELOPMENT REVIEW DIVISION
201 N. Stone Avenue, 2nd Floor
Tucson, Arizona 85701-1207

CARMINE DEBONIS, JR. Phone: (520) 740-6586
Director FAX: (520) 740-6380
September 26, 2002

TO: Kevin Morrow, GDA Southwest, L.L.C.

THRU: Craig Gross, City of Tucson Development Services

FROM: Subhash Raval, P.E., Manager
Pima County Development Review & Technical Services Divisions

SUBJECT: Universal Avionics
Development Plan
D02-028



We have reviewed the above-referenced project on behalf of the Pima County Wastewater Management Department. The following comments are offered for your use:

1. There is currently capacity in the existing downstream sewerage system for this development. This response is not to be construed as a commitment for conveyance capacity allocation, but rather an analysis of the existing sewerage system as of this date.

2. We have sent to your office under separate cover a Private Sewer Service Agreement for the proposed number of fixture units. The Sewer Service Agreements must be signed by the owner of record, notarized, and all three originals returned to this office before we can approve the Development Plan.

3. Based on our evaluation, this project would qualify for Participating sewer connection rates.

4. Add the Development Plan case number, D02-028, to the title block of each sheet. This number should be shown larger or bolder than the cross reference numbers.

5. Label sewers as (existing, I-83-225, 8") on Medina Road, Bonney Avenue, and Universal Way. In addition, it is difficult to determine where the existing sewer lines are located, therefore, label the existing sewers as defined in the legend.

6. Show and label all proposed and existing on site sewers as well as the HCS connections.

7. Please clarify: Is the 6" HCS for proposed building #6 existing or new? If it is a new tie-in the connection will need to be made at a manhole.

8. If the answer above is new add the following general note:

A Project Construction Permit must be secured from Pima County Wastewater Management Department before beginning any work on this project.

9. If answer #7 is new provide the following:

Show the proposed manhole rim and invert elevations for all manhole locations, as required by item G.1 on page 21 of the Pima County Development Plan Requirements checklist, effective September 1, 2000.

10. Revise General Notes #9 to reflect the current conditions. Identify if all the sewers are existing and private or portion of the sewer is existing and private and new sewer will be private.

11. We will require a Revised Development Plan.

If you wish to discuss the above comments, please contact Tim Rowe at 740-6563.




Subhash Raval, P.E., Division Manager
Pima County Development Review & Technical Services Divisions


SR/DK/dk
Copy: Project
10/09/2002 TIM ROWE PIMA COUNTY WASTEWATER Approved Comments on file.