Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: D02-0027
Parcel: 12510006A

Review Status: Completed

Review Details: CDRC RESUBMITTAL - DEVELOPMENT PLAN

Permit Number - D02-0027
Review Name: CDRC RESUBMITTAL - DEVELOPMENT PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/28/2002 FRODRIG2 START INITIALIZE THE WORKFLOW Completed
10/30/2002 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond PIMA COUNTY
DEVELOPMENT SERVICES DEPARTMENT
DEVELOPMENT REVIEW DIVISION
201 N. Stone Avenue, 2nd Floor
Tucson, Arizona 85701-1207

CARMINE DEBONIS, JR. Phone: (520) 740-6586
Director FAX: (520) 740-6380
October 23, 2002

TO: Lane D. Oden, Fines & Oden, P.L.C.

THRU: Craig Gross, City of Tucson Development Services

FROM: Tim Rowe, P.E., Development Review Engineer (Wastewater)
Pima County Development Review Division

SUBJECT: Target at El Con Mall
Development Plan - 1st Submittal
D02-0027



We have reviewed the above-referenced project on behalf of the Pima County Wastewater Management Department. The following comments are offered for your use:

1. There is currently capacity in the existing downstream sewerage system for this development. This response is not to be construed as a commitment for conveyance capacity allocation, but rather an analysis of the existing sewerage system as of this date.

2. Based on the preliminary sewer layout as shown on the referenced , this project would qualify for Participating sewer connection fee rates.

3. Add the development plan case number, D02-0027, to the title block of each sheet. This number should be shown larger or bolder than the cross reference numbers.

4. Sheets SP1.1, SP1.2, SP1.3 & SP1.4: The major drawing titles on each of these sheets indicate that they all show the southeast ¼ of the project. Revise as necessary.

5. Sheet SP1.1: Add the following General Note:

ANY RELOCATION, MODIFICATION, ETC., OF THE EXISTING UTILITIES AND/OR PUBLIC IMPROVEMENTS REQUIRED BY THIS DEVELOPMENT WILL BE AT NO EXPENSE TO THE PUBLIC.

6. Sheet SP1.1: Add the following General Note:

ANY WASTEWATER DISCHARGED INTO THE PUBLIC SANITARY SEWERAGE SYSTEM SHALL MEET THE REQUIREMENTS OF THE INDUSTRIAL WASTE ORDINANCE (PIMA COUNTY ORDINANCE NO. 1991-140, AS AMENDED).

7. Sheet SP1.1: Add the following General Note:

THE TOTAL NUMBER OF EXISTING AND PROPOSED WASTEWATER FIXTURE UNITS IS
.

(with the blank appropriately filled in.) A revised Sewer Service Agreement may be required if the number of existing and proposed wastewater fixture units exceeds 144.

8. Sheet SP1.1: Add the following General Note:

THE ON-SITE SEWERS ARE EXISTING AND PRIVATELY MAINTAINED AND OPERATED.

9. Sheets SP1.1, SP1.2, SP1.3 & SP1.4: Show the existing on-site private sewers, and how they connect to the adjacent public sewers. The public and private sewers must be shown using different linetypes, shown and described in the legend. Label each public and private sewer with its size, and plan number.

10. Sheet C1.0: Revise the leader line for the label that reads, "Existing 8" Private Sewer (PN G-350), so that it points to the sewer line.

11. Sheet C1.0: Have the sewer lines shown on this sheet been field verified? The configuration of the private sewer lines shown on Sheet C1.0 does not match that shown on the development plan prepared by Stantec in the year 2000, under plan number D00-0017 or on PCWWM’s Base Map 2. Please revise and/or advise as necessary.

12. Sheets SP1.1, SP1.2, SP1.3 & SP1.4: Show the House Connection Sewer lines for the existing and proposed buildings. Label each with its size and the letters, "HCS".

13. Will the Target utilize a private wastewater pumping station? If so, the plans should indicate this, and Pima County Codes Title 13.20.030.F, and Title 13.20.040 will apply.

14. If fixture unit credits for demolition and conversion will be sought per 13.20.040.F, please contact Ilene Deckart at 740-6544 and begin this process.

15. A resubmittal of bluelines showing the revisions is required. Additional comments may be forthcoming regarding the resubmittal.

If you wish to discuss the above comments, please contact me at 740-6563.




Tim Rowe, P.E., Development Review Engineer (Wastewater)
Pima County Development Review Division

TR/tr
Copy: Project
10/30/2002 FRODRIG2 PIMA COUNTY WASTEWATER Approv-Cond PIMA COUNTY
DEVELOPMENT SERVICES DEPARTMENT
DEVELOPMENT REVIEW DIVISION
201 N. Stone Avenue, 2nd Floor
Tucson, Arizona 85701-1207

CARMINE DEBONIS, JR. Phone: (520) 740-6586
Director FAX: (520) 740-6380
December 11, 2002

TO: Lane D. Oden, Fines & Oden, P.L.C.

THRU: Craig Gross, City of Tucson Development Services

FROM: Tim Rowe, P.E., Development Review Engineer (Wastewater)
Pima County Development Review Division

SUBJECT: Target at El Con Mall
Development Plan - 2nd Submittal
D02-0027



We have reviewed the above-referenced project on behalf of the Pima County Wastewater Management Department. The following comments are offered for your use:

1. Sheet SPT.1A: Revise General Note 31 to read:

ON-SITE SEWERS ARE EXISTING, AND OPERATED AND MAINTAINED ON A PRIVATE BASIS.

2. Subject to the above, the development plan is hereby approved. The required revision may be shown on the Mylars.

3. Due to the relatively small number of wastewater fixture units that will be served, no Sewer Service Agreement will be required.

If you wish to discuss the above comments, please contact me at 740-6563.



Tim Rowe, P.E., Development Review Engineer (Wastewater)
Pima County Development Review Division

TR/tr
Copy: Project
Gary Hanson, HMN Architects (via fax: 784-0964)
Gerry Edwards, MMLA (via fax: 922-1290)
10/30/2002 KAY MARKS PIMA COUNTY ADDRESSING Approved PIMA COUNTY
DEVELOPMENT SERVICES DEPARTMENT
201 N. Stone Ave, 1st Floor
Tucson, Arizona 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370



TO : CITY PLANNING
FROM : KAY MARKS, ADDRESSING OFFICIAL
SUBJECT : D02-0027 TARGET@EL CON MALL/REVISED DEVELOPMENT PLAN
DATE : October 30, 2002


***********************************************************************************************************

The above referenced project has been reviewed by this Division for all matters pertaining to street naming/ addressing, and we hereby approve this project.




1. Submit a 24 x 36 Mylar of approved Development Plan to City Planning. Signed and dated mylar will be forwarded to Pima County Addressing prior to the assignment of addresses.

2. All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.
11/01/2002 JOE LINVILLE DEVELOPMENT SERVICES LANDSCAPE Approved
11/13/2002 PAUL MACHADO DEVELOPMENT SERVICES ENGINEERING Approved To: Craig Gross

SUBJECT: Target Store at El Con mall
D02-0027 (Second Review)
T14S, R14E, Section 09

RESUBMITTAL REQUIRED: DP & GP

The Development Plan (DP) & Grading Plan (GP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Development Plan:

1. Coordinate with the engineer to rename "Grading plan".
2. Show estimated cut and fill quantities per D.S. 2-02.2.1.17. Please explain how you arrived at 370 cy cut and fill.
3. The sidewalk scuppers must be shown on the DP. Previous comment.
4. Add basin responsibility note to general notes. Please provide a note indicating your response in note 7.
5. Correct the discrepancy between the loading zone on the grading plan and the loading zone on the Development Plan. The DP still shows the loading zone different from the grading plan, this may be due to the plan scale. Previous comment.

Grading Plan:

1. The review of the grading is complete for DP purposes only.
2. Please explain how you arrived at 370 cy cut and fill. Previous comment.
3. The sidewalk scuppers must be shown on the DP. Previous comment.
4. Coordinate with the architect to rename "Grading plan".

If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us

Paul Machado
Senior Engineering Associate
11/13/2002 PAUL MACHADO DEVELOPMENT SERVICES ENGINEERING Approved Date: December 30, 2002
From: Paul Machado/Engineering Section
Subject: Target Store at El Con mall
D02-0027 (Third Review) T14S, R14E, Section 09

Resubmittal Required: None
Development Plan: All necessary comments have been addressed. The Development plan is now approved by the Engineering/Floodplain section.

If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate
c: File
Target El Con 3
11/15/2002 FRODRIG2 DEVELOPMENT SERVICES ZONING Approved CDRC TRANSMITTAL

TO: Development Services Department FROM: Patricia Gehlen
Plans Coordination Office Principal Planner


PROJECT:
Target at El Con Mall
Development Plan
D02-027
TRANSMITTAL: November 15, 2002
DUE DATE: November 12, 2002


COMMENTS CODE SECTION/
DEVELOPMENT
STANDARD

1. Section 5.3.8.2, LUC, permits a maximum of one year from the date of application to obtain approval of a development plan. If, at the end of that time, the development plan has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this development plan is August 25, 2003.

2. The location map must be revised to meet the criteria detailed in DS
DS 2-05.2.1.D
3. The original development plan case number (D00-0017) must be added back to each sheet of the development and landscape plans near the title block and to general note 5 on sheet SPT1.A.
DS 2-05
4. Please dimension the width of all the pedestrian circulation systems around the proposed building to ensure compliance with minimum code standards. In addition, revise the development plan to show how the pedestrian circulation system will be routed west of the proposed Target, around the proposed loading zones, to the rest of the mall. This is necessary for pedestrian safety reasons.
DS 2-05.2.4.D.3 & K
DS 2-08

5. Although the vacation of the electrical easement has been provided, the vacation of the gas easement (dkt 1686 pg 128) has not. Please provide.
DS 2-05.2.3.B
6. All requested revision must be made to all applicable plans (development, landscape, drainage, grading etc.).
DS 2-07
If you have any questions about this transmittal, please call Patricia Gehlen, (520) 791-5608.
11/15/2002 FRODRIG2 DEVELOPMENT SERVICES ZONING Approved The above listed development plan has been approved with a minor change required to the landscape plan for the the sidewalk location behind the proposed loading zones.