Review Details: REVISION - DEV PLAN
Permit Number - D01-0015
Review Name: REVISION - DEV PLAN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/10/2005 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 05/11/2005 | MATT FLICK | ENGINEERING | REVIEW | Approved | No objection to revised plan. Matt Flick, PE Engineering Manager 11MAY05 |
| 05/11/2005 | JIM EGAN | COT NON-DSD | FIRE | Approved | The Development Plan is approved May 11, 2005. |
| 05/13/2005 | GLYNDA ROTHWELL | UTILITIES | TUCSON ELECTRIC POWER | Approved | SUBJECT: TUCSON COUNTRY DAY SCHOOL D01-0015 Tucson Electric Power Company has reviewed and approved the development plan submitted for review May 10, 2005. In order to apply for electric service, call the New Construction Department at (520) 770-2062. Submit a final set of plans including approved site, offsite and electrical load plans. Include a CD with the AutoCAD version of the plans. If easements are required, they will be secured by separate instrument. Your final plans should be sent to: Juan Valenzuela Design/Build - DB 102 Tucson Electric Power Company P. O. Box 711 Tucson, AZ 85702 Please call me at (520) 917-8745, should you have any questions. Liza Castillo Right of Way Agent Land Management Tucson Electric Power Co. (520) 917-8745 lcastillo@tep.com <mailto:lcastillo@tep.com> |
| 05/17/2005 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Development Services Center Plans Coordination Office FROM: Peter McLaughlin Senior Planner FOR: Patricia Gehlen Principal Planner PROJECT: D01-015 Tucson Country Day School Revision to Development Plan TRANSMITTAL: 5-17-05 DUE DATE: 5-23-05 1. Remove the word PAAL from the 20-foot fires lane since this is not intended to provide access to parking areas and the minimum required width of a 2-way PAAL is 24 feet. 2. Continuous on-site pedestrian circulation must be provided between the buildings per DS 2-08. Dimension sidewalks and show how onsite pedestrian circulation connects to the proposed buildings. DS 2-05.2.4.K DS 2-08.4.1 & 5.1 If you have any questions about this transmittal, please call Peter McLaughlin, (520)791-5608. |
| 05/17/2005 | KAY MARKS | PIMA COUNTY | ADDRESSING | Denied | 201 N. STONE AV., 1ST FL TUCSON, AZ 85701-1207 KAY MARKS ADDRESSING OFFICIAL PH: 740-6480 FAX #: 740-6370 TO: CITY PLANNING FROM: KAY MARKS, ADDRESSING OFFICIAL SUBJECT: D01-0015 TUCSON COUNTRY DAY SCHOOL/DEVELOPMENT PLAN DATE: May 16, 2005 The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and the following matters must be resolved prior to our approval: Buildings are not numbered accurately (per Pima County Code and per existing Development Plan). Please verify with PC Addressing prior to approval of this project. jg |
| 05/19/2005 | JCLARK3 | ENV SVCS | REVIEW | Denied | * No known landfill with in 1000 feet of this development. * Dumpster enclosure does not meet the development standards. * Location for the enclosure has access and the 14' x 40' clear area and could be serviced at this location. * No provisions shown for recycling. |
| 05/20/2005 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | Submit landscape and native plant preservation plans. Submit copies of previously approved plans for reference. |
| 05/26/2005 | ROGER HOWLETT | COT NON-DSD | COMMUNITY PLANNING | Approved | DEPARTMENT OF URBAN PLANNING & DESIGN Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT D01-0015 Tucson Country Day School 05/23/05 () Tentative Plat (xxxxx) Development Plan () Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other CROSS REFERENCE: NEIGHBORHOOD PLAN: Wrightstown Neighbohood Plan GATEWAY/SCENIC ROUTE: N/A COMMENTS DUE BY: SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: (xxxxx) No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies With Plan Policies () See Additional Comments Attached () No Additional Comments - Complies With Planning Comments Submitted on: () Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan () Other REVIEWER: vf 791-4505 DATE: 05/21/05 |
| 05/26/2005 | DALE KELCH | COT NON-DSD | TRAFFIC | Approved | Traffic Engineering recommends APPROVAL of this revised DP. D. Dale Kelch, EIT Senior Engineering Associate Traffic Engineering Division (520)791-4259x305 (520)791-5526 (fax) dale.kelch@tucsonaz.gov |
| 06/04/2005 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Denied | COMMUNITY DESIGN REVIEW COMMITTEE DEVELOPMENT SERVICES June 4, 2005 Cathy Rex Cathy A. Rex, Architect 3149 East Prince Road, Suite 151 Tucson, AZ 85716 Subject: D01-0015 Tucson Country Day School Development Plan Dear Cathy: Your submittal of May 10, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed: ALL BLUELINES MUST BE FOLDED 5 Copies Revised Development Plan (environmental services, zoning, landscaping, addressing, DSD) 3 Copies Revised Landscape Plan (zoning, landscaping, DSD) Should you have any questions, please call me at 791-5608, ext. 1179. Sincerely, Patricia Y. Gehlen CDRC Manager All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/ Via fax: 322-5880 |