Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: D00-0057
Parcel: 115160310

Address:
1117 W GRANT RD

Review Status: Completed

Review Details: RESUBMITTAL - CDRC - DEV PLAN

Permit Number - D00-0057
Review Name: RESUBMITTAL - CDRC - DEV PLAN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/15/2005 FERNE RODRIGUEZ START PLANS SUBMITTED Completed
06/17/2005 KAY MARKS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV., 1ST FL
TUCSON, AZ 85701-1207

KAY MARKS
ADDRESSING OFFICIAL
PH: 740-6480
FAX #: 740-6370


TO: CITY PLANNING
FROM: KAY MARKS, ADDRESSING OFFICIAL
SUBJECT: D00-057 TOTAL TOOL/REVISED DEVELOPMENT PLAN
DATE: June 17, 2005



The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.

APPROVED WITH THE FOLLOWING CONDITION: CORRECT FAIRVIEW ST TO FAIRVIEW AV. (LOCATION MAP) ON MYLAR.

NOTE:

1: Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar of approved
Development Plan to City Planning. Signed and dated Mylar will be forwarded to Pima
County Addressing prior to assignment of addresses.

2: All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.











jg
06/21/2005 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Based on the expansion of floor area the requirements of LUC 3.7 apply to the entire site. LUC 3.7.1.2.B.2.b

2) Provide a street landscape border along Grant Road.
LUC 3.7.2.4.A
06/21/2005 PATRICIA GILBERT ENGINEERING REVIEW Approved
06/24/2005 JCLARK3 ENV SVCS REVIEW Approved
06/27/2005 PETER MCLAUGHLIN ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Development Services Center
Plans Coordination Office

FROM: Peter McLaughlin
Senior Planner

FOR: David Rivera
Principal Planner

PROJECT:
D00-037
Total Tool
Grant Road
Development Plan Revision

TRANSMITTAL: June 27, 2005
DUE DATE: June 29, 2005

1. Revise the math in the parking calculation to reflect the actual gross floor area including the proposed expansion. Based on the drawing the calculation should read 8,064 S.F ¸ 500 S.F. = 16 parking spaces required and provided.

2. The new proposed location of the 12' x 55' loading zone does not allow trucks to maneuver into and out of the space. Revise location of loading zone.

3. Between any PAAL and building a 5-foot pedestrian refuge, including a 4-foot sidewalk must be maintained. With the new proposed location of the single parking space adjacent to the loading zone, the access drive to this space is considered a PAAL. The pedestrian refuge area must be physically separated from the PAAL by means of concrete curbing, barriers, railings, bollards or other means. Revise plan to show the pedestrian refuge and sidewalk along the west side of the building.
DS 3-05.2.2.B.1
DS 2-08.4.1

If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.

RESUBMITTAL OF THE FOLLOWING ITEMS IS REQUIRED: revised development plan.
06/28/2005 GLYNDA ROTHWELL UTILITIES TUCSON ELECTRIC POWER Approved SUBJECT: TOTAL TOOL, INC.
D00-0057

Tucson Electric Power Company has reviewed and approved the development plan
submitted for review June 16, 2005.

Please call me at (520) 917-8745, should you have any questions.

Liza Castillo
Right of Way Agent
Land Management
Tucson Electric Power Co.
(520) 917-8745
lcastillo@tep.com <mailto:lcastillo@tep.com>
07/01/2005 FRODRIG2 PIMA COUNTY WASTEWATER Denied June 27, 2005

TO: Rob Caylor
Robert Caylor Construction Co.

THRU: Patricia Gehlen
City of Tucson, Development Services Department

FROM: Dickie Fernández, E.I.T.
Pima County Development Services Department
Development Review Division (Wastewater)

SUBJECT: Total Tool, Inc.
Development Plan – 2nd Submittal
D00-0057


The proposed sewer collection lines to serve the above-referenced project have been reviewed on behalf of the Pima County Department of Environmental Quality (PDEQ) and the Pima County Wastewater Management Department (PCWMD). This review letter may contain comments pertaining to the concerns of either Department. The following comments are offered for your use.


Add the following two General Notes

THE LANDSCAPING WITHIN ALL PUBLIC SEWER EASEMENTS SHOWN HEREON SHALL BE IN ACCORDANCE WITH THE PLANTING GUIDELINES OF PC/COT STANDARD DETAIL WWM A-4.

NO PERMANENT STRUCTURES (I.E., MASONRY WALLS, FENCES, ETC.) MAY BE CONSTRUCTED ON OR THROUGH THE PUBLIC SEWER EASEMENTS SHOWN HEREON WITHOUT SEPARATE WRITTEN CONSENT OF THE PIMA COUNTY WASTEWATER MANAGEMENT DEPARTMENT.

There is a label indicating a 33-foot RCP sewer within a sewer easement. Show the sewer easement boundaries and clearly point them out. Additionally, revise the diameter of the 33-foot RCP sewer to reflect the proper material and pipe diameter.

A 10-foot wide sewer easement is shown point only to one of the two boundaries. Please revise your layout and clearly show the easement limits and its proper location.

Parking is being proposed on top of an existing public manhole. Delete all parking spaces within a 12-foot radius of existing manhole 9911-03A.

We will require a revised set of drawings and a response letter addressing each comment. Additional comments may be made during the review of these documents.

The next submittal of this project will be the 3rd submittal. A check for the review fee of this submittal in the amount of $39.00 made out to PIMA COUNTY TREASURER must accompany the revised set of bluelines and response letter.

For any questions regarding the fee schedule, please go to http://www.pimaxpress.com/SubDivision/Documents/Fees.PDF where you may find the appropriate wastewater review fees at the bottom of page 1. If the number of sheets changes, please adjust the review fee accordingly.

If you have any questions regarding the above mentioned comments, please contact me. Sincerely,





Dickie Fernández, E.I.T.
Telephone: (520) 740-6947

Copy: Project
07/09/2005 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 9, 2005

Rob Caylor
Robert Caylor Construction Company
6711 East Camino Principal
Tucson, AZ 85715

Subject: D00-0057 Total Tool, Inc. Development Plan

Dear Rob:

Your submittal of June 16, 2005 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

4 Copies Revised Development Plan (waste water, zoning, landscaping, DSD)

3 Copies Revised Landscape Plan (zoning, landscaping, DSD)



Should you have any questions, please call me at 791-5608, ext. 1179.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Via fax: 290-6014