| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/13/2009 | TERRY STEVENS | ZONING | REVIEW | Completed | Zoning has no adverse comments regarding this annexation. Any future development will be required to meet the LUC and Development Standards code criteria to the extent that they apply. |
| 10/14/2009 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Completed | Annexation noted by TDOT-Traffic |
| 10/14/2009 | MATT FLICK | ENGINEERING | REVIEW | Completed | PDSD Engineering has no objection regarding the establishment of City I-2 Zoning to the Raytheon Annexation District. It should be noted that the annexed area contains areas that were subject to regulation by the Pima County Regional Flood Control District for: Floodplain Inundation Erosion (incl. setbacks from watercourses) Provision for Detention and Retention Facilties Protection of Riparian Habitat The City's Floodplain Ordinance also contains similar regulations that may affect development within the annexed area. Both the City's and County's floodplain regulations apply to private and public lands (but not military reservations). |
| 10/15/2009 | DAVE MANN | FIRE | REVIEW | Approved | Approved |
| 12/08/2009 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | No comments. |
| 12/11/2009 | JOHN BEALL | COMMUNITY PLANNING | REVIEW | Completed | PLANNING & DEVELOPMENT SERVICES DEPARTMENT C15-09-03 Raytheon - Annexation District County CI-2 to City I-2 General Plan, Rincon/Southeast Subregional Plan 12/11/09 jb The above referenced rezoning case is for the establishment of original City zoning from Pima County CI-2 (County General Industrial) to City I-2 (City Heavy Industrial), requested by Judith Imhoff, on behalf of the City of Tucson for annexation. The proposed annexation district is situated on 1,621 acres adjacent to the Tucson International Airport. The annexation district consists of three parcels owned by the United States of America, with a portion of a fourth parcel owned by the City of Tucson and leased to the Tucson Airport Authority, which is sublet to Raytheon Missile Systems of Tucson. Current development on the site consists of the Raytheon Facility. The surrounding zones and land uses are the following; north and northeast is County CI-2 zone consisting of research facilities and the Tucson International Airport, to the east is County CI-2 zone and the Tucson International Airport, to the south is a City I-2 and County CI-2 zone, consisting of mainly vacant land, and to the west is County C-RH zone, vacant land. The annexation site is within the boundaries of the General Plan, and the Rincon/Southeast Subregional Plan which provide land use direction with relevant policies as outlined below: The request to establish original City zone from Pima County CI-2 to City of Tucson I-2 is consistent with the General Plan direction, which recognizes that the long-term prosperity and vitality of the city is centered around making infrastructure expansion more economical, and providing for a rational pattern of land development. The General Plan supports industrial development that will contribute to Tucson's overall economic vitality and community character. The Rincon/Southeast Subregional Plan reflects that high-intensity industrial and park industrial planned land use respond to existing development patterns within or adjacent to the I-10 corridor, including Tucson International Airport and Davis-Monthan Air Force Base. The request provides an opportunity to add an existing research facility to the City of Tucson that will contribute to the City's economic vitality and community character. The annexation site is within current County Overlays: Airport Environs (AEZ) and Major Streets and Routes (MS&R) which will translate to the City Overlay Zones. s:\caserev\rezoning\rez09-10\C15-09-03-/Raytheon Annexation District.doc |
| 12/14/2009 | JULIE YBARRA | SIGNS | SIGN CODE REVIEW | Passed | |
| 12/14/2009 | MWYNEKE1 | REZ AGENCY REVIEW | PARKS & RECREATION | Passed | |
| 12/14/2009 | MWYNEKE1 | ENV SVCS | REVIEW | Passed | |
| 12/14/2009 | MWYNEKE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Passed | |
| 12/14/2009 | MWYNEKE1 | REZ AGENCY REVIEW | OFFICE OF CONSERVATION & SUSTAINABLE DEVELOPMENT | Passed | |
| 12/14/2009 | MWYNEKE1 | REZ AGENCY REVIEW | PIMA ASSN OF GOVTS | Passed | |
| 12/14/2009 | MWYNEKE1 | REZ AGENCY REVIEW | PIMA CNTY WASTEWATER | Passed | |
| 12/14/2009 | MWYNEKE1 | REZ AGENCY REVIEW | SCHOOL DISTRICT | Passed | |
| 12/14/2009 | MWYNEKE1 | REZ AGENCY REVIEW | ADOT | Passed | |
| 12/14/2009 | MWYNEKE1 | REZ AGENCY REVIEW | TDOT RTA | Passed | |
| 12/14/2009 | MWYNEKE1 | REZ AGENCY REVIEW | TDOT STREETS | Passed | |
| 12/14/2009 | MWYNEKE1 | REZ AGENCY REVIEW | OTHER AGENCIES | Passed | |
| 12/14/2009 | MWYNEKE1 | DOT ENGINEERING | REVIEW | Passed |