Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TS-PRM-1222-00079
Parcel: 132131280

Address:
3434 S KINO PW

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.1

Permit Number - TS-PRM-1222-00079
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/05/2023 Signs REQUIRES RESUBMIT RE: wall and canopy sign review
For: First Watch / 3434 S Kino PW
permit: TS-PRM-1222-00079
Reviewer: H. Thrall (Heather.Thrall@tucsonaz.gov)
Date: 1/5/23

Codes: Unified Development Code (UDC) 7A Sign Standards, National Electrical Code (NEC), Tucson- Pima County Outdoor Lighting Code (OLC), International Building Code (IBC)2018

1. UDC
A) thank you for the landlord permission letter up front, appreciated.
B) please break down each sign as A- F (cabinets are 1, line of text the next, and so on)
C) please provide the street frontage for this location on the location plan - both Tucson Marketplace and Kino.
D) please provide sign locations using arrows on the location plan - call out all 6
E) please update the application to include the wall sign and canopy sign on the NE elevation
F) please label each elevation on the color elevation diagram
G) please call out the sign height from grade to top of the sign (approx is fine) on each elevation view

2. NEC / OLC:
A) list the volts, amps, circuits for each sign type on the construction diagram
B) add note that signs to shut off at midnight curfew via timer
C) add note for detail 1 that the sign is both front and halo style lit
D) add note that the UL sticker, manufacturer sticker and installer sticker will be on each sign
E) add note that maximum color temp is 4400k per internally illuminated sign
F) a central timer is also ok if preferred versus putting one on each sign power supply - just note (some corporate franchises need this, so clarifying for you it is allowed)

3. IBC
A) please note how the canopy sign letters are mounted to the raceway and mounted to the canopy

Please resubmit all documents - except landlord document - to your portal under permit TS-PRM-1222-00079. As this will be a resubmittal, you may email me when you've resubmitted so I can see it faster in my review list - Heather.Thrall@tucsonaz.gov and of course email if you have questions. Thank you