Permit Review Detail
Review Status: In Review
Review Details: PERMANENT SIGN REVIEW v.2
Permit Number - TS-PRM-1125-00484
Review Name: PERMANENT SIGN REVIEW v.2
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/26/2025 | Commercial Electrical Standard | APPROVED | |||
| N/A | Commercial Building Standard | PENDING ASSIGNMENT | |||
| 11/26/2025 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TS-PRM-1125-00484 (7101 E 22ND ST TUCSON, AZ 85710) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Outdoor Lighting Review: 1. Add the following notes to each Internally Illuminated Sigh sheet: “As per the City of Tucson Outdoor Lighting Code – The internally illuminated sign shown on this page does not exceed the color temperature of 4400K, OLC 501.3.2.” “24 hour programmable timer installed to comply with the COT Outdoor Lighting Code. The means of controlling the specific “off” curfew shall be by a 24 hour timing device that includes stand-by power to maintain the time and program for a minimum of 6 hours. OLC 403.5 & 501.6. “ Provide permanent curfew “off” time sign or notice: Whenever any curfew “off” time is required by this Code, a permanent sign or notice shall be installed at the time control device stating the required turn-off time. Such sign or notice may be installed within the cover of the time control device such that it is visible whenever the device is set or adjusted, OLC 403.5.2. Suggested wording is as follows: “Set off time for Sign no later than 10:00PM MST in accordance with City of Tucson/Pima County Outdoor Lighting Code. Penalty for non-compliance per Outdoor Lighting Code Section 107.4. Penalties shall not exceed $750.00 for individuals and $10,000.00 for other legal entities.” (Adjust wording as needed for type of lighting to which curfew applies and the applicable curfew time.) 2. Halo Illuminated Signs (if the design is not fully internally illuminated per chapter 2 and chapter 5 of the OLC) shall meet all requirements of the Outdoor Lighting Code including color temperature, lumen caps and shielding requirements, OLC 501.4. Additional comments may be forthcoming with additional plans/updates. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 12/12/2025 | Signs Standard | REQUIRES RESUBMIT | Sign Review TS-PRM-1125-00484 7101 E. 22nd St. Plan review for the above referenced structure has been completed by Tami Goltz. This letter reflects comments to be addressed. Additional comments may be provided in subsequent reviews. Code reference: Unified Development Code, Article 7A: Sign Standards, adopted Outdoor Lighting Code, adopted Building Code. Please feel free to reach out with any questions you may have. Tami.Goltz@tucsonaz.gov or 520-837-5049. 1. TC-COM-0725-01410 Needs to be paid for and issued prior to the sign approval being given. Please resubmit once the building permit has been paid for and issued. 2. Site plan is required to show site visibility triangles per section 10-01.5.0 of the Uniform Development Code. Please review these standards and display SVTs on site plan as required. 3. The frontage needs to be shown on the site plan for both frontages off of Kolb and 22nd St roadways so allowable signage amounts can be calculated. 4. You must specify materials the wall is constructed of and appropriate attachment methods, not a variety of options as shown on page 5 of the sign drawings. 5. The following exact language needs to be added to the sign drawings and adhered to: ⦁ All signs and power supply components are UL listed. ⦁ All signs shall have UL sticker, manufacturer sticker and installer sticker, located on the exterior of the sign for inspections. ⦁ All dedicated sign circuits shall be labeled. ⦁ A safety lock out shall be provided for all signs where the shut off switch is not directly visible to the sign. ⦁ 24 hour programmable timer installed to comply with the COT Outdoor Lighting Code. ⦁ As per the City of Tucson Outdoor Lighting Code the internally illuminated sign as shown on this page does not exceed the 4400k color temp. 6. The drawings note White QWIK MOND2 7100LK LEDS. These are out of compliance with the Outdoor Lighting Code and must be brought into compliance. 7. Total number of AMPs the sign will pull when illuminated. 8. Installation and attachment methods must be listed for each sign. 9. The freestanding sign and clearance bar require sealed engineering. 10. Disconnect switch must be labeled on all signs, including the freestanding sign. |