Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.2
Permit Number - TS-PRM-1123-00605
Review Name: PERMANENT SIGN REVIEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/20/2023 | Sign Post Review Express | PENDING ASSIGNMENT | |||
| 12/20/2023 | Commercial Building | REQUIRES RESUBMIT | engineered sign package - wall sign high up on building While the proposed sign is indicating using 103 mph as the basis to calculate the structural design, there is no structural calculation submitted to go with it. Please submit these calculations responding to all lateral forces including wind uplift that will be affecting the sign and the sign parts such as bolts used and how many are being used to resist the forces. Please resubmit. |
||
| 12/18/2023 | Commercial Electrical | REQUIRES RESUBMIT | Engineered wall sign on rac Please address the electrical plan review comments and provide a written response. 1. Indicate with a note on the sign plan the source of the dedicated sign power. If installed by separate permit please indicate. NEC 600. 2. Provide compliance with the sign curfew requirements per the 2012 City of Tucson Outdoor Lighting Code section 501.5, 501.6, 403.5. 3. Provide branch circuit disconnecting means at the sign location as required per NEC art 600.6(A)(1),(2), (3). Ref’ 2018 IBC section 107.2.1, 2017 NEC, 2012 City of Tucson Outdoor Lighting Code. eway - high up on building elevation |
||
| 12/20/2023 | Signs | REQUIRES RESUBMIT | RE: wall sign review For: Cross Country Mortgage / 4801 E Broadway Sign permit: TS-PRM-1123-00605 Date: 12/20/23 Reviewer: H. Thrall (Heather.Thrall@tucsonaz.gov) Codes: Unified Development Code (UDC) 7A, Sign Standards, National Electrical Code (NEC) 600, Tucson - Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 1. I acknowledge the sign area and sign type (wall sign on raceway, with landlord permission document) is allowed and within permissible sign area. 2. The full plan set does not appear to be uploaded. Please check all your documents, as it appears some electrical and structural data is missing. Sign package is missing the standard lighting notations and the engineer's structural calculations. Also, a special inspection is needed for this package for mounting and staff is providing the form to the contractor to pass to the engineer for their review / stamp / appointment of inspection and qualified special inspector. Add these standard electrical notes: All components will be UL rated. All manufacturer, UL and installer stickers will be on the signs. A dedicated sign circuit will be provided and will be labeled at circuit breaker. Safety lock out to be provided where shut off switch is not visible to the sign. Timing device shall be provided and set to midnight shut off. Please email Heather.Thrall@tucsonaz.gov once you have resubmitted, so staff can get the package back into review quickly for you. |