Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TS-PRM-1026-00388
Parcel: 116206340

Address:
115 S LINDA AV

Review Status: In Review

Review Details: PERMANENT SIGN REVIEW v.1

Permit Number - TS-PRM-1026-00388
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
11/02/2026 Site Engineering Standard NOT REQUIRED Site is located in XS_500, floodplain use permit not required.
N/A Sign Post Review Express PENDING ASSIGNMENT
N/A Signs Standard PENDING ASSIGNMENT
11/19/2026 Commercial Building Standard REQUIRES RESUBMIT Requires resubmit. Please note the following:

1. Electrical and installation details are illegible, please upload digital document if available, or a higher resolution scan
11/19/2026 Commercial Electrical Standard REQUIRES RESUBMIT Requires resubmit. Please note the following:

1. Electrical and installation details are illegible, please upload digital document if available, or a higher resolution scan
11/09/2026 Historic REQUIRES RESUBMIT HISTORIC REVIEW REQUIRED: This property is located within the RNA/IID Downtown HD. Minor Historic Review is required.
APPLICATION REQUIREMENTS: Historic Review requires the submittal of a supplemental Design Package. As part of your Design Package, please include the following items combined into a single PDF: (1) project description/narrative, (2) site plan showing existing and proposed, (3) elevations showing existing and proposed, (4) photographs of existing conditions (provide photographs of entire facades/each elevation where the sign is proposed and provide photos of details).
For more information reference the following handout, HISTORIC REVIEW INFORMATION GUIDE: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/historic-preservation/historic-review-information-guide_091726.pdf.
CREATE HISTORIC SUB-RECORD: You will need to create Special Districts-Historic sub-record following these instructions: https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/sub-records.pdf. Once you are ready to submit your Design Package, upload it as a single PDF to your Special District-Historic Sub-Record. The Historic review for your project will be processed and recorded in the Sub-Record.
QUESTIONS: For questions or to set up a meeting with Historic staff, please contact: Michael.Taku@tucsonaz.gov
11/19/2026 Outdoor Lighting Standard REQUIRES RESUBMIT Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.

Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Outdoor Lighting Review:



Add the following notes to each Internally Illuminated Sigh sheet:



“As per the City of Tucson Outdoor Lighting Code – The internally illuminated sign shown on this page does not exceed the color temperature of 4400K, OLC 501.3.2.”



“24-hour programmable timer installed to comply with the COT Outdoor Lighting Code.

The means of controlling the specific “off” curfew shall be by a 24-hour timing device that includes stand-by power to maintain the time and program for a minimum of 6 hours. OLC 403.5 & 501.6. “



Provide permanent curfew “off” time sign or notice:

Whenever any curfew “off” time is required by this Code, a permanent sign or notice shall be installed at the time control device stating the required turn-off time. Such sign or notice may be installed within the cover of the time control device such that it is visible whenever the device is set or adjusted, OLC 403.5.2.



Suggested wording is as follows: “Set off time for Sign no later than 10:00PM MST in accordance with City of Tucson/Pima County Outdoor Lighting Code. Penalty for non-compliance per Outdoor Lighting Code Section 107.4. Penalties shall not exceed $750.00 for individuals and $10,000.00 for other legal entities.” (Adjust wording as needed for type of lighting to which curfew applies and the applicable curfew time.)