Permit Number: TS-PRM-0926-00324
Parcel: 10120036M

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.1

Permit Number - TS-PRM-0926-00324
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/28/2026 Commercial Electrical Standard APPROVED
09/29/2026 Sign Post Review Express PENDING ASSIGNMENT
09/28/2026 Commercial Building Standard REQUIRES RESUBMIT Requires resubmit. Please note the following:

1. Please provide stamped structural engineer's drawings of monument sign foundation
09/28/2026 Outdoor Lighting Standard REQUIRES RESUBMIT Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.

If you have any questions, I can be reached at jorge.ruiz@tucsonaz.gov

Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC).

https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf

Outdoor Lighting Review:

Add the following notes to each Internally Illuminated Sigh sheet:

“As per the City of Tucson Outdoor Lighting Code – The internally illuminated sign shown on this page does not exceed the color temperature of 4400K, OLC 501.3.2.”

“24-hour programmable timer installed to comply with the COT Outdoor Lighting Code.

The means of controlling the specific “off” curfew shall be by a 24-hour timing device that includes stand-by power to maintain the time and program for a minimum of 6 hours. OLC 403.5 & 501.6. “

Provide permanent curfew “off” time sign or notice:

Whenever any curfew “off” time is required by this Code, a permanent sign or notice shall be installed at the time control device stating the required turn-off time. Such sign or notice may be installed within the cover of the time control device such that it is visible whenever the device is set or adjusted, OLC 403.5.2.

Suggested wording is as follows: “Set off time for Sign no later than 10:00PM MST in accordance with City of Tucson/Pima County Outdoor Lighting Code. Penalty for non-compliance per Outdoor Lighting Code Section 107.4. Penalties shall not exceed $750.00 for individuals and $10,000.00 for other legal entities.” (Adjust wording as needed for type of lighting to which curfew applies and the applicable curfew time.)
09/29/2026 Signs Standard REQUIRES RESUBMIT Review Comments :9/29/26
Sign Review Plan review for TS-PRM-0926-00324 (3170 W EL CAMINO DEL CERRO TUCSON, AZ 85745). The above-referenced structure has been completed by Aaron F. This letter reflects comments to be addressed. Additional comments may be provided in subsequent reviews. Code reference: Unified Development Code, Article 7A: Sign Standards, adopted Outdoor Lighting Code, adopted Building Code. Please feel free to reach out with any questions you may have to pdsd_signpermits@tucsonaz.gov.

1)All dimensions must be in Feet. Decimal format, not feet and/or inches. For instance, 5’3” = 5.25’.
2)Sight Visibility Triangles are not properly displayed on the site plan. Please review Section 10-01.5.0 of the Unified Development Code on the requirements for Sight Visibility Triangles and revise the site plan to show correct SVTs.
3) Please add the street frontage dimensions so that total calculations for square footage can be assessed.
4)Please verify setback on monument sign.
Minimum setback: 20 from curb to leading edge of sign. 7A.10.2.C.2.A.1.i.D
5) Overall height of monument sign is limited to 10' from grade to top. 7A.6.5.a
6)Please call out the square footage of each sign
7)Gas canopy sign area will include the length of the blue line all around as sign square footage. Please call out this dimension on your drawings
8)Digital sign requires: A letter from the manufacturer of the EMC to the City of Tucson that says the following...

1. Name of the manufacturer.

2. The EMC model number/name.

3. [EMC Model #] is fully capable of lowering to 200 nits at night.

4. [EMC Model #] is FCC compliant.
9)Disconnect switch on monument sign
09/04/2026 Signs Application Completeness Express REVIEW COMPLETED